{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY4213-7CC11","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY4213-7CC11","canonicalUrl":"https://aoctrl.com/siemens/5SY4213-7CC11","factsUrl":"https://aoctrl.com/api/mcp/products/5SY4213-7CC11","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY4213-7CC11, miniature circuit breaker, 2-pole, C tripping characteristic, 10 kA breaking capacity per EN 60898, 400 V AC, 72 V DC, 2 MW, halogen-free, silicon-free, sealable.","salesMarkdown":"The Siemens 5SY4213-7CC11 is a 2-pole miniature circuit breaker from the SENTRON family, designed with a C tripping characteristic and a 10 kA breaking capacity per EN 60898. It is rated for 400 V AC (440 V multi- or single-phase) and up to 72 V DC, making it a fit for branch-circuit protection in industrial control panels, mechanical engineering, and railway-auxiliary applications. The 10 kA breaking capacity at 400 V AC (per EN 60898) means this MCB can safely interrupt a fault current up to that level without welding its contacts or cascading failure to upstream gear. That is sufficient for most secondary distribution panels behind a transformer or main breaker — if your available fault current exceeds 10 kA, you need a higher-rated device upstream. The C-curve trips at 5 to 10 times rated current, so it holds through the 3-5x inrush of a small motor or solenoid valve but clears a hard short in under 10 ms. Rated for a -40 °C to 75 °C ambient, this MCB handles unheated enclosures in cold climates and hot cabinet interiors near drives or transformers. The power loss per pole is 1.4 W at rated current in hot operating state — negligible for a single device, but worth summing if you pack 20+ units in a sealed enclosure. The 2 MW width (36 mm) and 70 mm installation depth fit standard DIN-rail distribution boards, and the quick-assembly system with combined top/bottom terminals speeds wiring on repetitive builds.","metaTitle":"Siemens 5SY4213-7CC11 SENTRON MCB, 2P C-curve, 10 kA","metaDescription":"Siemens 5SY4213-7CC11 SENTRON miniature circuit breaker, 2-pole, C characteristic, 10 kA breaking capacity per EN 60898. Active production. Quoted on request.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"36 mm","title":"5SY4213-7CC11","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Miniature circuit breaker 400 V 10kA, 2-pole, C, 13A for railway applications","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"2P","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","at AC rated value":"400 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"Yes","Design Of The Product":"For railway applications","Energy Limitation Class":"3","Combined Terminal Bottom":"Yes","Suitability For Operation":"Mechanical engineering / industry","Neutral Conductor Switching":"No","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"C","according to EN 60898 rated value":"10 kA","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","Type Of Voltage Of The Operating Voltage":"AC","Value Range Of The Supply Voltage Frequency":"50/60 Hz","operating voltage at DC rated value maximum":"72 V","with multi-phase operation at AC rated value":"440 V","with single-phase operation at AC rated value":"440 V","vibration resistance according to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.4 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e809874d7a1650a01bb5c622974a285a.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=131817&mlfb=5SY4213-7CC11"},"ai":{"faq":[{"question":"What is the breaking capacity of this MCB?","answer":"The 5SY4213-7CC11 has a 10 kA breaking capacity per EN 60898 at 400 V AC. This means it can safely interrupt a fault current up to 10,000 amps without damage."},{"question":"What is the C tripping characteristic used for?","answer":"The C-curve trips at 5 to 10 times rated current, making it suitable for circuits with moderate inrush currents from small motors, transformers, and solenoid valves. It avoids nuisance tripping on startup while still clearing hard shorts quickly."},{"question":"What is the temperature range for this MCB?","answer":"The 5SY4213-7CC11 is rated for ambient temperatures from -40 °C to 75 °C. This covers unheated outdoor enclosures in winter as well as hot cabinet interiors near drives or transformers."},{"question":"Where can I buy 5SY4213-7CC11 and get current pricing?","answer":"This part is sourced to order against an RFQ through independent distribution. Submit a request for quote to confirm current availability and pricing — no stock count or lead-time figure is published here because the supply position shifts daily."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY4213-7CC11","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY4213-7CC11 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}