{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY4506-5","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY4506-5","canonicalUrl":"https://aoctrl.com/siemens/5SY4506-5","factsUrl":"https://aoctrl.com/api/mcp/products/5SY4506-5","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY4506-5, miniature circuit breaker, 2-pole (1P+N), 6 A rated, tripping characteristic A, 10 kA per EN 60898, 35 kA per IEC 60947-2, 36 mm width.","salesMarkdown":"## Siemens 5SY4506-5 — 6 A, Characteristic A, 2-Pole MCB Pole configuration is 1P+N (2-pole housing) with neutral conductor switching, so it isolates both line and neutral on a single-width 36 mm footprint — common in single-phase final subcircuits where you want full isolation without a separate switched neutral bar. Rated 6 A at 35 °C, but the continuous current must be derated as panel ambient rises: 5.63 A at 40 °C, 5.44 A at 45 °C, 5.24 A at 50 °C, 5.04 A at 55 °C, and 4.82 A at 60 °C. If the enclosure runs hot from adjacent drives or transformers, size up one frame or account for the reduced ampacity at your worst-case internal temperature. Operating ambient range is -40 °C to 75 °C, with humidity limits of 95 % up to 55 °C, 55 % up to 70 °C, and 35 % up to 75 °C — the part handles cold storage and hot panel conditions, but high humidity at elevated temperatures is the binding constraint for outdoor or unventilated enclosures. Accepts any mounting position and any supply-side connection orientation — no top/bottom restriction, which simplifies busbar runs in crowded panels. Combined terminal top and bottom accepts standard screw-clamp wiring. Certified to IEC/EN 60898-1 and IEC/EN 60947-2 / UL 1077. Current production — no end-of-life notice.","metaTitle":"Siemens 5SY4506-5 SENTRON MCB, 6A, 10kA, Char A, 2-Pole","metaDescription":"Siemens 5SY4506-5 SENTRON miniature circuit breaker, 6A rated, 10kA (EN 60898) / 35kA (IEC 60947-2), characteristic A, 2-pole 1P+N, 36mm wide. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"36 mm","title":"5SY4506-5","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC / EN 60898-1, IEC / EN 60947-2 / UL1077","description":"Miniature circuit breaker 230 V 10kA, 1+N-pole, A, 6A, D=70 mm","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","at AC / rated value":"6 A","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"Yes","according to EN 61346-2":"F","at 35 °C / rated value":"6 A","at 40 °C / rated value":"5.63 A","at 45 °C / rated value":"5.44 A","at 50 °C / rated value":"5.24 A","at 55 °C / rated value":"5.04 A","at 60 °C / rated value":"4.82 A","Combined Terminal Bottom":"Yes","according to IEC 81346-2":"F","Suitability For Operation":"Mechanical engineering / industry","Neutral Conductor Switching":"Yes","Number Of Modular Width Units":"2","Tripping Characteristic Class":"A","Position / Of Power Supply Cord":"Any","according to EN 60898 / rated value":"10 kA","according to IEC 60947-2 / rated value":"35 kA","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","Type Of Voltage / Of The Operating Voltage":"AC","Value Range / Of The Supply Voltage Frequency":"50/60 Hz","at DC / according to IEC 60947-2 / rated value":"15 kA","operating voltage / at DC / rated value / maximum":"72 V","vibration resistance / according to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","with single-phase operation / at AC / rated value":"250 V","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/db529f6b204bf9b59c3600aee25c76f7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=256774&mlfb=5SY4506-5"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY4506-5","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY4506-5 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}