{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY4610-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY4610-6","canonicalUrl":"https://aoctrl.com/siemens/5SY4610-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SY4610-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY4610-6 miniature circuit breaker, 4-pole (3P+N), B tripping characteristic, 10 A rated current, 10 kA (EN 60898) / 20 kA (IEC 60947-2) breaking capacity.","salesMarkdown":"It breaks faults at 10 kA per EN 60898-1 and 20 kA per IEC 60947-2 / UL 1077, covering both residential and industrial panel applications. The B-curve trips between 3 and 5 times rated current — 30 A to 50 A for this 10 A unit — making it a first-choice for resistive and general-purpose loads where inrush is moderate. The 4-module-width (72 mm) footprint fits standard DIN-rail enclosures; the quick-assembly fastening method and any mounting position simplify panel integration. Rated current derates with ambient temperature: 10 A at 35 °C, 9.52 A at 40 °C, down to 8.48 A at 60 °C. The MCB is certified to IEC / EN 60898-1 and IEC / EN 60947-2 / UL 1077, covering both residential and industrial standards. The energy limitation class is 3, meaning it limits let-through energy effectively for downstream equipment protection.","metaTitle":"Siemens 5SY4610-6 SENTRON MCB, 4P, B-Curve, 10 A, 10 kA","metaDescription":"Siemens 5SY4610-6 SENTRON miniature circuit breaker, 4-pole (3P+N), B-curve, 10 A rated, 10 kA breaking capacity per EN 60898. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["4-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"72 mm","title":"5SY4610-6","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC / EN 60898-1, IEC / EN 60947-2 / UL1077","description":"Miniature circuit breaker 400 V 10kA, 3+N-pole, B, 10A, D=70 mm","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"3P+N","Number Of Poles":"4","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","at AC / rated value":"10 A","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"Yes","Energy Limitation Class":"3","according to EN 61346-2":"F","at 35 °C / rated value":"10 A","at 40 °C / rated value":"9.52 A","at 45 °C / rated value":"9.27 A","at 50 °C / rated value":"9.02 A","at 55 °C / rated value":"8.75 A","at 60 °C / rated value":"8.48 A","Combined Terminal Bottom":"Yes","according to IEC 81346-2":"F","Suitability For Operation":"Mechanical engineering / industry","Number Of Modular Width Units":"4","Tripping Characteristic Class":"B","Position / Of Power Supply Cord":"Any","Product Feature / Touch Protection":"Yes","according to EN 60898 / rated value":"10 kA","according to IEC 60947-2 / rated value":"20 kA","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","Type Of Voltage / Of The Operating Voltage":"AC","Value Range / Of The Supply Voltage Frequency":"50/60 Hz","at DC / according to IEC 60947-2 / rated value":"15 kA","Product Component / Neutral Conductor Switching":"Yes","with multi-phase operation / at AC / rated value":"440 V","operating voltage / at DC / rated value / maximum":"72 V","vibration resistance / according to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","with single-phase operation / at AC / rated value":"440 V","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cce7b58c7a3511c9f28d3bfc0d9b5b0e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=22535&mlfb=5SY4610-6"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 5SY4610-6?","answer":"Submit an RFQ through this listing. The part is sourced to order via independent distribution; availability and pricing are confirmed at quote time."},{"question":"What is the closest functional alternative to 5SY4610-6?","answer":"The 5SY4140-7 is a 4-pole B-curve MCB in the same SENTRON family, but it is a 40 A unit versus the 10 A 5SY4610-6. They share the same 4-module footprint and breaking capacity ratings, so a panel designed for one can accept the other without rewiring — only the overcurrent protection level changes."},{"question":"What compliance documentation does Siemens provide for 5SY4610-6?","answer":"The MCB carries certifications to IEC / EN 60898-1, IEC / EN 60947-2, and UL 1077. It is halogen-free and silicon-free. Standard documentation includes the declaration of conformity and material compliance declarations on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY4610-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY4610-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}