{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY4613-7","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY4613-7","canonicalUrl":"https://aoctrl.com/siemens/5SY4613-7","factsUrl":"https://aoctrl.com/api/mcp/products/5SY4613-7","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY4613-7, miniature circuit breaker, 4-pole (3P+N), rated current 13 A, tripping characteristic C, breaking capacity 10 kA per EN 60898 / 20 kA per IEC 60947-2.","salesMarkdown":"The 4-module-width footprint (72 mm wide) occupies four 18 mm DIN-rail positions — plan your enclosure fill accordingly. This breaker switches the neutral conductor (3P+N), so it opens all live conductors on a fault — required in many European and IEC-based installations where the neutral is not bonded to ground downstream. The combined terminal design at both top and bottom accepts a range of conductor sizes and busbar comb profiles, simplifying panel wiring. ## Derating and environmental limits The 13 A rating is at 35 °C ambient. At 40 °C it derates to 12.38 A, at 50 °C to 11.73 A, and at 60 °C to 11.02 A — a roughly 15% drop from the nameplate at the top end of the operating range. Ambient temperature range spans -40 °C to 75 °C, with humidity limits of 95% up to 55 °C, 55% up to 70 °C, and 35% up to 75 °C. The breaker is certified to IEC / EN 60898-1 (the standard for household and similar installations) and IEC / EN 60947-2 (the industrial standard for low-voltage switchgear and controlgear), plus UL 1077 for supplementary protection in North American panels. Overvoltage category III (fixed installation) and energy limitation class 3 apply.","metaTitle":"Siemens 5SY4613-7 SENTRON MCB, 13A C-Curve 4P 10kA","metaDescription":"Siemens 5SY4613-7 SENTRON miniature circuit breaker, 13A rated, C tripping characteristic, 4-pole (3P+N), 10kA breaking capacity per EN 60898. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["4-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"72 mm","title":"5SY4613-7","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC / EN 60898-1, IEC / EN 60947-2 / UL1077","description":"Miniature circuit breaker 400 V 10kA, 3+N-pole, C, 13 A, D=70 mm","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"3P+N","Number Of Poles":"4","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","at AC / rated value":"13 A","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"Yes","Energy Limitation Class":"3","according to EN 61346-2":"F","at 35 °C / rated value":"13 A","at 40 °C / rated value":"12.38 A","at 45 °C / rated value":"12.05 A","at 50 °C / rated value":"11.73 A","at 55 °C / rated value":"11.38 A","at 60 °C / rated value":"11.02 A","Combined Terminal Bottom":"Yes","according to IEC 81346-2":"F","Suitability For Operation":"Mechanical engineering / industry","Neutral Conductor Switching":"Yes","Number Of Modular Width Units":"4","Tripping Characteristic Class":"C","Position / Of Power Supply Cord":"Any","according to EN 60898 / rated value":"10 kA","according to IEC 60947-2 / rated value":"20 kA","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","Type Of Voltage / Of The Operating Voltage":"AC","Value Range / Of The Supply Voltage Frequency":"50/60 Hz","at DC / according to IEC 60947-2 / rated value":"15 kA","with multi-phase operation / at AC / rated value":"440 V","operating voltage / at DC / rated value / maximum":"72 V","vibration resistance / according to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","with single-phase operation / at AC / rated value":"440 V","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/28d100f6c7a824a86bdb12b2210d9b76.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=319548&mlfb=5SY4613-7"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SY4613-7?","answer":"10 kA per EN 60898 and 20 kA per IEC 60947-2. The higher figure applies when the breaker is used in industrial switchgear applications per the 60947-2 standard."},{"question":"What is the width of 5SY4613-7 in DIN-rail modules?","answer":"72 mm, which is 4 modular width units (each 18 mm). It occupies four adjacent positions on a standard DIN rail."},{"question":"Where can I buy 5SY4613-7 and get current pricing?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an inquiry for a firm quote."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY4613-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY4613-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}