{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY4613-7CC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY4613-7CC","canonicalUrl":"https://aoctrl.com/siemens/5SY4613-7CC","factsUrl":"https://aoctrl.com/api/mcp/products/5SY4613-7CC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY4 series, miniature circuit breaker, 4-pole (3P+N), tripping characteristic C, rated current 13 A, breaking capacity 10 kA at 400 V AC per EN 60898, 5 kA per UL 1077.","salesMarkdown":"## What this 4-pole C-curve MCB does on the line It's built for 400 V AC circuits and carries a 10 kA breaking capacity per EN 60898, with a 5 kA rating per UL 1077 and CSA C22.2 No.235. That C-curve means it's sized for moderate inrush loads — motors, transformers, capacitor banks — where the start-up surge is higher than a resistive load but not extreme. Mount it any position, any orientation; it's rated for ambient temperatures from -25 to +55 °C and storage down to -40 °C. That's a real-world panel range, not a lab number. ## Integration and compliance notes The breaker is 72 mm wide (4 width units), 90 mm tall, and 76 mm deep, with an installation depth of 70 mm. It's sealable, halogen-free, silicon-free, and carries touch protection (IP20 with connected conductors). That IP20 rating is standard for a panel-mounted device — it keeps fingers out but isn't rated for washdown. Energy limiting class 3 gives good let-through energy reduction on faults, which helps with downstream coordination. ## Delta against a common sibling: 5SY3132-6 A buyer often asks whether the 5SY4613-7CC drops into a panel wired for the 5SY3132-6. The short answer: no, not without rewiring. The 5SY4613-7CC is a 4-pole (3P+N) breaker; the 5SY3132-6 is a 3-pole unit. The physical footprint is wider (4 width units vs 3), and the terminal layout differs. Both are SENTRON 5SY-series MCBs with a C-curve, but the pole count is the hard stop. If your panel was laid out for a 3-pole breaker, this one won't fit the same DIN-rail slot without a new busbar and re-termination.","metaTitle":"Siemens 5SY4613-7CC SENTRON MCB 4P C 13A 10kA EN 60898","metaDescription":"Siemens 5SY4613-7CC SENTRON miniature circuit breaker, 4-pole (3P+N), C-curve, 13 A, 10 kA breaking capacity per EN 60898. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["4-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Solid":"0.75 ... 35 mm²","Width":"72 mm","title":"5SY4613-7CC","Height":"90 mm","Sealable":"Yes","Stranded":"0.75 ... 35 mm²","Rated Value":"50/60 Hz","description":"Miniature circuit breaker 400 V 10kA, 3+N-pole, C, 13A","Halogen-Free":"Yes","Silicon-Free":"Yes","Mounting type":"Quick assembly system","During Storage":"-40 ... +75 °C","Number of poles":"4","Type of voltage":"AC","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Ambient temperature":"-25 ... +55 °C","Product designation":"Miniature circuit breaker","Protection class IP":"IP20, with connected conductors","at AC / rated value":"400 V","Overvoltage category":"III","Combined Terminal Top":"Yes","Energy limiting class":"3","Number of width units":"4","Number of poles / Note":"3P+N","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","Combined Terminal Bottom":"Yes","circuit-breaker / Design":"5SY4CC","Suitability for operation":"Mechanical engineering / industry","Current / at AC / rated value":"13 A","Tripping characteristic class":"C","at DC / rated value / maximum":"72 V","acc. to EN 60898 / rated value":"10 kA","Position / of power supply cord":"Any","Product feature / Touch protection":"Yes","Influence of the surrounding temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","at AC / acc. to UL 1077 and CSA C22.2 No.235":"5 kA","Tightening torque / with screw-type terminals":"2.5 ... 3.5 N·m","Product function / neutral conductor switching":"Yes","with multi-phase operation / at AC / rated value":"440 V","with single-phase operation / at AC / rated value":"440 V","Mechanical service life (switching cycles) / typical":"10 000","Tightening torque [lbf·in] / with screw-type terminals":"22 ... 31 lbf·in"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bba9a3d9fe9f1a54676b2471accd4c0a.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=278143&mlfb=5SY4613-7CC"},"ai":{"faq":[{"question":"Where can I buy 5SY4613-7CC and what is the lead time?","answer":"The part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What is 5SY4613-7CC's depth?","answer":"The depth is 76 mm, with an installation depth of 70 mm."},{"question":"What wire sizes does 5SY4613-7CC accept?","answer":"It accepts solid and stranded conductors from 0.75 to 35 mm²."},{"question":"Will 5SY4613-7CC drop into a panel wired for 5SY3132-6?","answer":"No. The 5SY4613-7CC is a 4-pole (3P+N) breaker while the 5SY3132-6 is 3-pole. The wider footprint and different pole count require rewiring and a new busbar."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY4613-7CC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY4613-7CC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}