{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY5110-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY5110-6","canonicalUrl":"https://aoctrl.com/siemens/5SY5110-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SY5110-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY5110-6, 1-pole B-curve miniature circuit breaker, 10 kA breaking capacity per IEC/EN 60898-2 and UL1077, 18 mm width, -40 to 75 °C.","salesMarkdown":"## What this 5SY5110-6 carries in a panel Rated breaking capacity sits at 10 kA per IEC/EN 60898-2 and UL1077, with a DC rating of 15 kA per IEC 60947-2. For motor-starting or heavy transformer loads you would step up to a C or D curve; this one is sized for the clean-switching side of the panel. ## Survives the nacelle — temperature and vibration range Rated from -40 °C to 75 °C ambient, with humidity derating above 55 °C (95 % RH at 55 °C, dropping to 35 % at 75 °C). That covers the inside of a turbine nacelle in winter shutdown or summer solar load — no up-tower swaps for thermal stress. Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz and 50 m/s² at 25–150 Hz. That is the shake a turbine gearbox and generator throw into the control cabinet. The 5SY5110-6 takes it without nuisance tripping or contact bounce — a spec that matters when the breaker is mounted on the same plate as the pitch-drive contactors. Halogen-free and silicon-free construction, which matters in sealed offshore cabinets where outgassing can fog optics or corrode silver contacts. Compliance documentation covers IEC/EN 60898-2 and UL1077. The UL listing means it is accepted for US and Canadian branch-circuit supplementary protection — not a full UL 489 breaker, but the correct class for control-panel overcurrent protection. RoHS, REACH, and CE declarations are standard with the SENTRON series; the manufacturer provides them on request. Width: 18 mm (one modular unit). Height: 90 mm. Quick-assembly fastening system — snaps onto DIN rail without tools, and the combined terminals accept both ferrule and pin terminals for stranded conductors.","metaTitle":"Siemens 5SY5110-6 SENTRON MCB, B-Curve 1P, 10kA IEC, UL1077","metaDescription":"Siemens 5SY5110-6 SENTRON miniature circuit breaker, 1-pole B-curve, 10 kA per IEC/EN 60898-2, UL1077 listed. -40 to 75 °C, vibration rated. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"76 mm","Poles":"1","Width":"18 mm","Height":"90 mm","Mounting":"Quick assembly system","IP Rating":"IP20","Product Status":"Active","Temp Operating Max":"75 °C","Temp Operating Min":"55 °C","Energy Limitation Class":"3"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/36d839b61c8c4a0e12bef1253805f0b0.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=263387&mlfb=5SY5110-6","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SY5110-6/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY5110-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY5110-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}