{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY5113-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY5113-6","canonicalUrl":"https://aoctrl.com/siemens/5SY5113-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SY5113-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY5113-6 miniature circuit breaker, 1-pole, B characteristic, 13 A, 10 kA breaking capacity, 76 mm depth, 18 mm width.","salesMarkdown":"At 40 °C ambient the continuous rating derates to 12.48 A, and at 55 °C it is 11.67 A. Rated for both AC and DC operation (universal current), but DC polarity must be observed — the supply cord position note says AC as required, DC polarity fixed. That's a wiring detail that catches people on DC circuits. Fits any standard distribution board or sub-panel. Sealable — you can lock the toggle in position for safety isolation. Halogen-free and silicon-free construction, which matters for clean-room or high-reliability environments where outgassing is a concern.","metaTitle":"Siemens 5SY5113-6 SENTRON MCB, 1P B-Char 13A 10kA, 76mm deep","metaDescription":"Siemens 5SY5113-6 SENTRON miniature circuit breaker, 1-pole, B-curve, 13A, 10kA breaking capacity per IEC/EN 60898-2 and UL1077. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SY5113-6","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC / EN 60898-2, UL1077","description":"Circuit breaker Universal current 220 V DC 230/400 V AC 10kA, 1-pole, B, 13A","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P","Number Of Poles":"1","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","at AC rated value":"13 A","at DC rated value":"220 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"Yes","at 35 °C rated value":"13 A","at 40 °C rated value":"12.48 A","at 45 °C rated value":"12.22 A","at 50 °C rated value":"11.95 A","at 55 °C rated value":"11.67 A","at 60 °C rated value":"11.39 A","Energy Limitation Class":"3","Combined Terminal Bottom":"Yes","Suitability For Operation":"universal current","Neutral Conductor Switching":"No","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"AC as required, observe DC polarity","Tripping Characteristic Class":"B","at DC according to EN 60898-2":"10 kA","according to EN 60898 rated value":"10 kA","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","Type Of Voltage Of The Operating Voltage":"AC/DC","at DC according to IEC 60947-2 rated value":"15 kA","Value Range Of The Supply Voltage Frequency":"50/60 Hz","operating voltage at DC rated value maximum":"250 V","with multi-phase operation at AC rated value":"440 V","with single-phase operation at AC rated value":"440 V","vibration resistance according to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","supply voltage with single-phase operation at AC rated value":"230 V","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.7 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d43ff7593c14a1d578c5dafa78ae3d0e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=142709&mlfb=5SY5113-6"},"ai":{"faq":[{"question":"What compliance documentation does the 5SY5113-6 carry?","answer":"It is certified to IEC/EN 60898-2 and UL1077, halogen-free and silicon-free. The standard IEC/EN 60898-2 covers miniature circuit breakers for overcurrent protection; UL1077 covers supplementary protectors for North American panels."},{"question":"Will 5SY5113-6 drop into a panel specified around 5SY5240-7?","answer":"The 5SY5113-6 shares the same 18 mm width, 76 mm depth, and DIN-rail mounting as other 5SY series breakers, so it fits the same panel footprint. The difference is rating and curve — 5SY5113-6 is 13 A B-curve, while 5SY5240-7 is a different rating. No rewiring needed for the same busbar system."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY5113-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY5113-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}