{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY5113-7","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY5113-7","canonicalUrl":"https://aoctrl.com/siemens/5SY5113-7","factsUrl":"https://aoctrl.com/api/mcp/products/5SY5113-7","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY5113-7, 1-pole miniature circuit breaker, 13 A, C characteristic, 10 kA breaking capacity per EN 60898, 1 MW unit width.","salesMarkdown":"The Siemens SENTRON 5SY5113-7 is a 1-pole miniature circuit breaker (MCB) rated at 13 A with a C tripping characteristic. It breaks fault currents up to 10 kA per EN 60898, which covers the majority of commercial and light industrial panel applications where the prospective short-circuit current at the distribution board stays under that threshold. The C-curve (5–10× In) handles moderate inrush from motor starters, contactor coils, and small transformers without nuisance tripping — the usual choice for mixed resistive-inductive loads in a final subcircuit. ## What the ratings mean for fit The 13 A rating at 50/60 Hz is the continuous current the MCB carries without opening under reference conditions (30 °C). In a real panel, the thermal derating table tells the story: at 40 °C the breaker is good for 12.38 A, at 50 °C it drops to 11.73 A, and at 60 °C you're down to 11.02 A. If the panel ambient runs hot — say, a sealed enclosure with drives — you need to account for that derating or step up one frame size. The 10 kA breaking capacity at 230/400 V AC per EN 60898 means the MCB can safely interrupt a fault up to that level; above that you'd need a current-limiting upstream device or a higher-rated breaker. The DC side is rated 10 kA per EN 60898-2 at 220 V, with polarity observed. At 18 mm wide (1 modular width), this breaker fits a standard DIN-rail distribution board with one slot per pole. The 76 mm depth and 70 mm installation depth mean it clears typical enclosure back-panel clearance — no special deep-box required. Mounting position is any, which simplifies layout in tight gland-plate areas. The IP20 rating (with connected conductors) is standard for enclosed distribution boards; if the breaker sees washdown or outdoor exposure, it needs a higher-rated enclosure around it. ## Panel integration notes Snap-on mounting to 35 mm DIN rail per EN 60715, with a quick-assembly system that latches without tools. The combined top and bottom terminals accept both busbar and conductor connections — handy for daisy-chaining multiple breakers in a distribution board. Touch protection is built into the terminal design (fingertip-safe per VDE). The sealable feature allows a lead seal or lockout tag to prevent unauthorized reset — useful on safety-critical or revenue-metered circuits. Halogen-free and silicon-free construction means no corrosive off-gassing in a confined panel.","metaTitle":"Siemens 5SY5113-7 SENTRON MCB, 13 A, 1P, C-Curve, 10 kA","metaDescription":"Siemens 5SY5113-7 SENTRON miniature circuit breaker, 13 A rated, 1-pole, C characteristic, 10 kA breaking capacity per EN 60898. Active production, sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SY5113-7","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Circuit breaker Universal current 220 V DC 230/400 V AC 10kA, 1-pole, C, 13A","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"1","Type Of Voltage":"AC/DC","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","acc. to IEC 81346-2":"F","at AC / rated value":"13 A","at DC / rated value":"220 V","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"Yes","Number Of Poles / Note":"1P","acc. to DIN EN 61346-2":"F","Energy Limitation Class":"3","at 40 °C / rated value":"12.38 A","at 45 °C / rated value":"12.05 A","at 50 °C / rated value":"11.73 A","at 55 °C / rated value":"11.38 A","at 60 °C / rated value":"11.02 A","Combined Terminal Bottom":"Yes","Suitability For Operation":"universal current","at DC / acc. to EN 60898-2":"10 kA","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","acc. to EN 60898 / rated value":"10 kA","Position / Of Power Supply Cord":"AC as required, observe DC polarity","Product Feature / Touch Protection":"Yes","Supply Voltage Frequency / Rated Value":"50/60 Hz","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","at DC / acc. to IEC 60947-2 / rated value":"15 kA","vibration resistance / acc. to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","Product Function / Neutral Conductor Switching":"No","with multi-phase operation / at AC / rated value":"440 V","operating voltage / at DC / rated value / maximum":"250 V","with single-phase operation / at AC / rated value":"440 V","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/3ef68afd8e372842b7e883dbad5be1db.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=220644&mlfb=5SY5113-7"},"ai":{"faq":[{"question":"What is the 5SY5113-7's breaking capacity?","answer":"The 5SY5113-7 has a 10 kA breaking capacity per EN 60898 at AC, and 10 kA per EN 60898-2 at 220 V DC."},{"question":"How do I get pricing and availability for the 5SY5113-7?","answer":"Pricing and availability are confirmed at quote time against an RFQ. Submit a request through the storefront for current lead time and price."},{"question":"What is the width and depth of the 5SY5113-7?","answer":"The 5SY5113-7 is 18 mm wide (1 modular unit) and 76 mm deep, with a 70 mm installation depth."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY5113-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY5113-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}