{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY5213-7CC11","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY5213-7CC11","canonicalUrl":"https://aoctrl.com/siemens/5SY5213-7CC11","factsUrl":"https://aoctrl.com/api/mcp/products/5SY5213-7CC11","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY5213-7CC11, 2-pole DC miniature circuit breaker, C characteristic, 10 kA breaking capacity at 440 V DC, 2 modular width units.","salesMarkdown":"## DC circuit specifics: polarity and terminal configuration This is a DC-only breaker — the type of voltage is DC, and the manufacturer notes to consider polarity when connecting the supply. Both top and bottom terminals are combined (screw and clamp), accepting a range of conductor sizes typical for 10 A to 16 A DC circuits. No neutral conductor switching; the 2-pole unit switches both lines (L+ and L–) simultaneously. The humidity limits are 95% RH up to 55 °C, derating to 35% RH at 75 °C.","metaTitle":"Siemens SENTRON 5SY5213-7CC11 Miniature Circuit Breaker, 2-P","metaDescription":"Siemens SENTRON 5SY5213-7CC11 2-pole DC miniature circuit breaker, C-tripping characteristic, 10 kA breaking capacity at 440 V DC. Active production. Sourced to order. Request quot","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"36 mm","title":"5SY5213-7CC11","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Circuit breaker Universal current 440 V DC 400 V AC 10kA, 2-pole, C, 13A for railway applications","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","Type Of Voltage":"DC","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","acc. to IEC 81346-2":"F","at DC / rated value":"440 V","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"Yes","Design Of The Product":"For railway applications","Number Of Poles / Note":"2P","acc. to DIN EN 61346-2":"F","at 40 °C / rated value":"11.57 A","at 45 °C / rated value":"10.78 A","at 50 °C / rated value":"9.93 A","at 55 °C / rated value":"9 A","at 60 °C / rated value":"7.96 A","Combined Terminal Bottom":"Yes","Suitability For Operation":"Railway","Number Of Modular Width Units":"2","Tripping Characteristic Class":"C","Position / Of Power Supply Cord":"Consider polarity","Product Feature / Touch Protection":"Yes","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","at DC / acc. to IEC 60947-2 / rated value":"10 kA","vibration resistance / acc. to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","Product Function / Neutral Conductor Switching":"No","operating voltage / at DC / rated value / maximum":"500 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ada5becdae096b446a72e51d8d2564b6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=482810&mlfb=5SY5213-7CC11"},"ai":{"faq":[{"question":"Where can I buy 5SY5213-7CC11 and how do I get a price?","answer":"This part is sourced to order through independent distribution. Submit an RFQ for current availability and pricing."},{"question":"Will 5SY5213-7CC11 drop into a panel that was specified around 5SY5250-7 without rewiring?","answer":"Yes. Both are 2-pole SENTRON 5SY series breakers with the same 36 mm width, 90 mm height, and 76 mm depth. The footprint and DIN-rail clip are identical."},{"question":"What compliance documentation does this brand provide for 5SY5213-7CC11?","answer":"The breaker is designed per IEC 60947-2 for DC applications. It is halogen-free and silicon-free. Specific RoHS, REACH, and UL documentation should be requested at quote time."},{"question":"What is the temperature derating for this DC breaker?","answer":"Rated current is 11.57 A at 40 °C, derating to 10.78 A at 45 °C, 9.93 A at 50 °C, 9 A at 55 °C, and 7.96 A at 60 °C. Size the breaker for the actual ambient temperature inside the enclosure."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY5213-7CC11","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY5213-7CC11 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}