{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY5410-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY5410-6","canonicalUrl":"https://aoctrl.com/siemens/5SY5410-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SY5410-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY5410-6, 4-pole miniature circuit breaker, B tripping characteristic, 10 kA breaking capacity per IEC/EN 60898-2, 15 kA per IEC 60947-2, rated AC 400 V / DC 880 V.","salesMarkdown":"## Siemens SENTRON 5SY5410-6 — 4-Pole B-Curve MCB for Universal Current It's rated for universal current (AC/DC), making it suitable for both power-distribution and DC-load circuits in control panels. Breaking capacity is 10 kA per IEC/EN 60898-2 and 15 kA per IEC 60947-2 — the higher figure under 60947-2 matters when the breaker is used as a branch-circuit protective device in an industrial panel, not just a final-subcircuit MCB. Rated operational voltage is 400 V AC (multi-phase or single-phase) and 880 V DC. Maximum DC voltage goes to 1 000 V, but the DC polarity must be observed per the manufacturer's note — the breaker is not polarity-independent on DC. The 10 kA SCCR under EN 60898-2 covers the vast majority of commercial and light-industrial final circuits. The 15 kA rating under IEC 60947-2 gives headroom for higher-fault installations when the breaker is applied as a branch-circuit device per that standard. The 4-pole design switches all live conductors but does not switch the neutral (Neutral Conductor Switching: No). That means the neutral is solidly connected through — fine for TN and TT systems where neutral is bonded to earth; not for IT systems requiring switched neutral. Temperature range is -40 °C to 75 °C, with humidity derating: max 95% RH up to 55 °C, then 55% up to 70 °C, and 35% up to 75 °C. If the panel runs hot and humid, stay below 55 °C to avoid nuisance tripping from condensation. Sealable (yes) — important for installations requiring tamper-proof locking after commissioning. Compliance documentation includes IEC/EN 60898-2 and UL1077 approvals. The dual standard listing means it's accepted in both IEC and UL jurisdictions — useful for export panels or multi-national projects.","metaTitle":"Siemens 5SY5410-6 SENTRON MCB, 4P, B-Curve, 10kA IEC/EN 6089","metaDescription":"Siemens 5SY5410-6 SENTRON miniature circuit breaker, 4-pole, B-curve, 10 kA per IEC/EN 60898-2, 15 kA per IEC 60947-2. Current lifecycle, sourced to order. Request a quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["4-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"72 mm","title":"5SY5410-6","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC / EN 60898-2, UL1077","description":"Circuit breaker Universal current 880 V DC 400 V AC 10kA, 4-pole, B, 10 A max. 1000 V DC","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"4P","Number Of Poles":"4","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","at AC rated value":"400 V","at DC rated value":"880 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"II","Combined Terminal Top":"Yes","Energy Limitation Class":"3","Combined Terminal Bottom":"Yes","Suitability For Operation":"universal current","Neutral Conductor Switching":"No","Number Of Modular Width Units":"4","Position Of Power Supply Cord":"AC as required, observe DC polarity","Tripping Characteristic Class":"B","at DC according to EN 60898-2":"10 kA","according to EN 60898 rated value":"10 kA","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","Type Of Voltage Of The Operating Voltage":"AC/DC","at DC according to IEC 60947-2 rated value":"15 kA","Value Range Of The Supply Voltage Frequency":"50/60 Hz","operating voltage at DC rated value maximum":"1 000 V","with multi-phase operation at AC rated value":"440 V","with single-phase operation at AC rated value":"440 V","vibration resistance according to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.3 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e64042e1dc3e99083f672e98764c35ef.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=353690&mlfb=5SY5410-6"},"ai":{"faq":[{"question":"What compliance documentation does this brand provide for 5SY5410-6 (RoHS, REACH, UL, IEC)?","answer":"The 5SY5410-6 is certified to IEC/EN 60898-2 and UL1077. It is halogen-free and silicon-free. RoHS/REACH declarations are standard with the SENTRON series — request them at quote time if needed for your compliance file."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY5410-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY5410-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}