{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY6002-7CC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY6002-7CC","canonicalUrl":"https://aoctrl.com/siemens/5SY6002-7CC","factsUrl":"https://aoctrl.com/api/mcp/products/5SY6002-7CC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON miniature circuit breaker, 5SY6002-7CC, 1P+N, 230V AC, 6kA, C-curve, 2A, DIN rail, 18mm wide.","salesMarkdown":"## Integrator note — 5SY6002-7CC The Siemens SENTRON 5SY6002-7CC is a 1P+N miniature circuit breaker with a C tripping characteristic, rated 2 A at 230 V AC and a 6 kA breaking capacity per IEC/EN 60898-1. The 1P+N design switches both phase and neutral, with neutral switching confirmed, making it suitable for single-phase final subcircuits where isolating the neutral is required. Snaps onto DIN rail per, occupying 1 modular width unit (18 mm wide per). Height is 90 mm. Mounting position is any, which simplifies layout in crowded enclosures. ## Environmental and derating Operating temperature range is -25 °C to +45 °C at up to 85% relative humidity, derating to 43% rF between 45 °C and 60 °C. Storage range is wider: -40 °C to +75 °C. Vibration resistance per IEC 60068-2-6 is confirmed. Mechanical service life is 4000 operating cycles typical.","metaTitle":"Siemens SENTRON 5SY6002-7CC MCB, 1P+N, C-curve, 2A, 6kA","metaDescription":"Siemens SENTRON 5SY6002-7CC miniature circuit breaker, 1P+N, 230V AC, 6kA breaking capacity, C characteristic, 2A rated current. DIN rail mount, 18mm wide. Active production. Quote","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SY6002-7CC","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC/EN60898-1, GB/T10963.1","description":"CIRCUIT BREAKER, 1MW 230V, 6KA, 1+N-POLE, C, 2A","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","lifecycle_stage":"current","Fastening Method":"DIN rail","Mounting Position":"any","at AC rated value":"230 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"No","Design Of The Product":"Miniature circuit breaker compact","Energy Limitation Class":"3","Combined Terminal Bottom":"No","Suitability For Operation":"Residential buildings/infrastructure","Neutral Conductor Switching":"Yes","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"C","according to EN 60898 rated value":"6 kA","Ambient Temperature During Operation":"-25...45°C: max. 85%rF, 45 60°C: max. 43%rF","Type Of Voltage Of The Operating Voltage":"AC","insulation voltage (Ui) at AC rated value":"250 V","with single-phase operation at AC maximum":"250 V","Value Range Of The Supply Voltage Frequency":"50/60 Hz","vibration resistance according to IEC 60068-2-6":"Yes","Mechanical Service Life (Operating Cycles) Typical":"4 000","Product Extension Installable Supplementary Devices":"Yes","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.3 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0ef89eddd74cb993c6961d50c747f3b2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=752834&mlfb=5SY6002-7CC"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SY6002-7CC?","answer":"The breaking capacity is 6 kA per IEC/EN 60898-1. This is the standard rating for residential and light commercial distribution boards."},{"question":"What is the width of 5SY6002-7CC?","answer":"The width is 18 mm, which is 1 modular width unit. It occupies a single pole space on the DIN rail."},{"question":"What is the depth of 5SY6002-7CC?","answer":"The overall depth is 76 mm. The installation depth (behind the panel face) is 70 mm."},{"question":"Will 5SY6002-7CC drop into a panel specified for 5SY6002-7KL?","answer":"Both are 1-pole SENTRON MCBs with the same 18 mm width and DIN rail mount, so the mechanical fit is identical. The 5SY6002-7CC is 1P+N (switched neutral) while the 5SY6002-7KL is a single-pole (1P) device — verify whether the panel wiring expects a switched neutral or a solid neutral bar before substituting."},{"question":"How do I get current pricing and availability for 5SY6002-7CC?","answer":"Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through our independent distribution network."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY6002-7CC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY6002-7CC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}