{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY6013-7","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY6013-7","canonicalUrl":"https://aoctrl.com/siemens/5SY6013-7","factsUrl":"https://aoctrl.com/api/mcp/products/5SY6013-7","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY6013-7, miniature circuit breaker compact, 1+N-pole, C 13 A, 6 kA per EN 60898, 230 V AC, 1 MW width.","salesMarkdown":"## What it is and what it does The Siemens 5SY6013-7 is a SENTRON miniature circuit breaker (MCB) in the compact 1+N-pole format — one protected pole plus a switched neutral, rated 13 A at 230 V AC with a C-curve trip characteristic. The C-curve means it trips between 5 and 10 times rated current, which is the standard choice for mixed resistive and moderate inductive loads like lighting circuits, small motors, and general-purpose outlets in residential and light commercial panels. Breaking capacity is 6 kA per EN 60898, which certifies it for fault currents up to that level in a 230 V AC single-phase system. That's adequate for most domestic and small commercial distribution boards where the prospective short-circuit current stays under 6 kA. ## Panel fit and mounting Snaps onto standard DIN rail (35 mm) and occupies one modular width unit (18 mm). Depth is 76 mm, installation depth 70 mm — check gland plate clearance if the panel is shallow. Mounting position is any, so it works upright, sideways, or inverted without derating the thermal trip. IP20 with connected conductors — fine inside a closed enclosure, not for wet or dusty environments. Pollution degree 2 and overvoltage category III are standard for fixed-installation distribution boards. ## Thermal derating and service life Rated 13 A at 30 °C ambient; at 40 °C it derates to 12.35 A, and at 45 °C to 12.09 A. If the panel runs hot — say next to a transformer or in a sealed enclosure — factor that derating into the load calculation. Mechanical service life is 10 000 switching cycles typical, which is fine for a distribution board that sees infrequent manual operation.","metaTitle":"Siemens 5SY6013-7 SENTRON MCB, C 13 A, 6 kA, 1+N","metaDescription":"Siemens 5SY6013-7 SENTRON miniature circuit breaker, 13 A C-curve, 6 kA breaking capacity per EN 60898, 1+N-pole 230 V. Current lifecycle stage. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"76 mm","Width":"18 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Halogen-Free":"Yes","Silicon-Free":"Yes","lifecycle_stage":"current","Fastening Method":"standard rail","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"2","Product Designation":"Miniature circuit breaker","acc. to IEC 81346-2":"F","at AC / rated value":"13 A","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"No","Design Of The Product":"Miniature circuit breaker compact","Energy Limitation Class":"3","at 30 °C / rated value":"13 A","at 40 °C / rated value":"12.35 A","at 45 °C / rated value":"12.09 A","Combined Terminal Bottom":"No","Suitability For Operation":"Residential buildings/infrastructure","Number Of Modular Width Units":"1","Tripping Characteristic Class":"C","acc. to EN 60898 / rated value":"6 kA","Position / Of Power Supply Cord":"Any","Product Feature / Touch Protection":"Yes","Type Of Voltage / Of The Operating Voltage":"AC","vibration resistance / acc. to IEC 60068-2-6":"Yes","insulation voltage (Ui) / at AC / rated value":"250 V","with single-phase operation / at AC / maximum":"250 V","Product Component / Neutral Conductor Switching":"Yes","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=324016&mlfb=5SY6013-7","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SY6013-7/alternatives.json"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 5SY6013-7?","answer":"Pricing and stock are confirmed at quote time. Submit an RFQ through the storefront; the sourcing team will return current availability and a firm price for your quantity."},{"question":"Will 5SY6013-7 drop into a panel that was specified around 5SY6006-7 without rewiring?","answer":"Yes — both are 1+N-pole SENTRON MCBs on the same 18 mm footprint with identical DIN-rail mounting and terminal layout. The difference is the rating: 5SY6006-7 is a 6 A C-curve, while this 5SY6013-7 is 13 A C-curve. No rewiring needed if the circuit load is within the 13 A rating."},{"question":"What compliance documentation does this brand provide for 5SY6013-7?","answer":"The MCB is designed and tested to EN 60898 for breaking capacity, carries a pollution degree 2 and overvoltage category III rating, and is halogen-free and silicon-free. Standard Siemens SENTRON documentation includes the declaration of conformity and CE marking."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY6013-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY6013-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}