{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY6106-8CC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY6106-8CC","canonicalUrl":"https://aoctrl.com/siemens/5SY6106-8CC","factsUrl":"https://aoctrl.com/api/mcp/products/5SY6106-8CC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON miniature circuit breaker, 5SY6106-8CC, 1-pole D-curve, 6 kA per EN 60898, 400 V AC, 18 mm width, halogen-free.","salesMarkdown":"The Siemens SENTRON 5SY6106-8CC is a 1-pole miniature circuit breaker with a D tripping characteristic, rated 6 kA breaking capacity per EN 60898 at 400 V AC. It's built for industrial panel applications where the load draws a heavy start-up surge. That 18 mm width keeps the panel dense — you can pack 16 of these in a standard 300 mm DIN rail section. Rated for a wide ambient temperature range: -40 °C to 75 °C, with humidity derating above 55 °C (max 95% RH at 55 °C, stepping down to 35% at 75 °C). That makes it usable in unheated outdoor cabinets or near hot machinery. Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz — solid for installation on a conveyor line or pump skid. Halogen-free and silicon-free construction reduces corrosion risk in sealed enclosures.","metaTitle":"Siemens SENTRON 5SY6106-8CC MCB, 1P D-Curve, 6 kA, 400 V","metaDescription":"Siemens SENTRON 5SY6106-8CC miniature circuit breaker, 1-pole D-curve, 6 kA breaking capacity per EN 60898, 400 V AC, 18 mm wide, halogen-free. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SY6106-8CC","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Miniature circuit breaker 230/400 V 6kA, 1-pole, D, 6A","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P","Number Of Poles":"1","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","at AC rated value":"400 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"Yes","Combined Terminal Bottom":"Yes","Suitability For Operation":"Mechanical engineering / industry","Neutral Conductor Switching":"No","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"D","according to EN 60898 rated value":"6 kA","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","Type Of Voltage Of The Operating Voltage":"AC","Value Range Of The Supply Voltage Frequency":"50/60 Hz","operating voltage at DC rated value maximum":"72 V","with multi-phase operation at AC rated value":"440 V","with single-phase operation at AC rated value":"440 V","at AC according to UL 1077 and CSA C22.2 No.235":"5 kA","vibration resistance according to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","supply voltage with single-phase operation at AC rated value":"230 V","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.2 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c3e3616ace57468d0fd3043caf9fd7d2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=218355&mlfb=5SY6106-8CC"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SY6106-8CC?","answer":"6 kA per EN 60898 at 400 V AC, and 5 kA per UL 1077 / CSA C22.2 No.235. That covers most branch-circuit protection in industrial control panels up to that fault level."},{"question":"Where can I buy 5SY6106-8CC?","answer":"We source this part to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock or lead-time figures on this page."},{"question":"Will 5SY6106-8CC fit a panel designed for 5SY6332-7CC?","answer":"Both are 1-pole SENTRON MCBs in the same 18 mm width and DIN-rail footprint, so mechanical fit is identical. The difference is the tripping curve — 5SY6106-8CC is D-curve (high inrush), while 5SY6332-7CC is a different characteristic. Check the load type before swapping; if the circuit needs D-curve, this part is a direct drop-in without rewiring."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY6106-8CC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY6106-8CC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}