{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY6208-7CC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY6208-7CC","canonicalUrl":"https://aoctrl.com/siemens/5SY6208-7CC","factsUrl":"https://aoctrl.com/api/mcp/products/5SY6208-7CC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY6208-7CC, miniature circuit breaker, 2-pole, C-curve 8 A, 6 kA breaking capacity per EN 60898, AC 440 V, 50/60 Hz, 2 MW, IP20, sealable.","salesMarkdown":"The Siemens 5SY6208-7CC is a SENTRON 2-pole miniature circuit breaker (MCB) with a C-curve trip characteristic, rated 8 A at 40 °C and 6 kA breaking capacity per EN 60898. This is the part you grab for a panel that needs a 2-module-width (36 mm) MCB — quick-assembly mounting, snaps onto DIN rail, any orientation accepted. The 8 A rating is the continuous current at 40 °C ambient — push it to 45 °C and you're down to 7 A; at 55 °C, 6.25 A. The derating curve is published, so don't just look at the 35 °C value (8 A) when the panel runs hot. Pollution degree 3 (conductive pollution, dry or temporary condensation) means it's fine inside a typical IP54 panel. ## Integration note — panel fit 2 modular width units (36 mm wide, 90 mm tall, 76 mm deep to the front of the housing, 70 mm installation depth behind the panel). Combined terminals top and bottom — same clamp accepts your incoming and outgoing conductors. Sealable, so you can lock the toggle position for tamper-proof circuits. Mounting position any; supply cord position any.","metaTitle":"Siemens 5SY6208-7CC SENTRON MCB, C-Curve 8A 2P 6kA","metaDescription":"Siemens SENTRON 5SY6208-7CC miniature circuit breaker, 2-pole C-curve 8 A, 6 kA per EN 60898, 440 V AC. Current production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"36 mm","title":"5SY6208-7CC","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Miniature circuit breaker 400 V 6kA, 2-pole, C, 8A","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"2P","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","at AC / rated value":"8 A","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"Yes","Energy Limitation Class":"3","according to EN 61346-2":"F","at 35 °C / rated value":"8 A","at 40 °C / rated value":"7.35 A","at 45 °C / rated value":"7 A","at 50 °C / rated value":"6.63 A","at 55 °C / rated value":"6.25 A","Combined Terminal Bottom":"Yes","according to IEC 81346-2":"F","Suitability For Operation":"Mechanical engineering / industry","Neutral Conductor Switching":"No","Number Of Modular Width Units":"2","Tripping Characteristic Class":"C","Position / Of Power Supply Cord":"Any","according to EN 60898 / rated value":"6 kA","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","Type Of Voltage / Of The Operating Voltage":"AC","Value Range / Of The Supply Voltage Frequency":"50/60 Hz","with multi-phase operation / at AC / rated value":"440 V","operating voltage / at DC / rated value / maximum":"72 V","vibration resistance / according to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","with single-phase operation / at AC / rated value":"440 V","Mechanical Service Life (Switching Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4bdadef3b3094c0cf79b3e74a53b0a28.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=37908&mlfb=5SY6208-7CC"},"ai":{"faq":[{"question":"What is 5SY6208-7CC's listed depth (76 mm) on this component line?","answer":"The housing depth is 76 mm, with an installation depth of 70 mm behind the panel face. That's the dimension you need for enclosure depth clearance."},{"question":"What is 5SY6208-7CC's listed width (36 mm) on this component line?","answer":"Width is 36 mm, which equals 2 modular width units on standard DIN-rail. That's the space it occupies in your enclosure layout."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY6208-7CC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY6208-7CC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}