{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY6210-6CC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY6210-6CC","canonicalUrl":"https://aoctrl.com/siemens/5SY6210-6CC","factsUrl":"https://aoctrl.com/api/mcp/products/5SY6210-6CC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY6 series miniature circuit breaker, 2-pole, B tripping characteristic, 10 A rated current, 6 kA breaking capacity at 400 V AC, 36 mm wide.","salesMarkdown":"The Siemens 5SY6210-6CC is a 2-pole miniature circuit breaker from the SENTRON 5SY6 series, designed for 400 V AC systems with a B tripping characteristic and a rated current of 10 A. Breaking capacity is 6 kA per EN 60898 at 400 V AC, and 5 kA per UL 1077 and CSA C22.2 No. 235 — enough for most secondary distribution panels in industrial environments. The 2-pole configuration (2P) switches both phase and neutral; no integral neutral switching (confirms neutral is not switched internally). Rated for any mounting position, with IP20 protection when conductors are connected. ## Integration and compliance notes Halogen-free and silicon-free construction suits sealed enclosures or clean-room adjacent panels where outgassing matters. Sealable for tamper-evident applications. Energy limiting class 3 — the MCB limits let-through energy well, aiding downstream coordination. Rated frequency 50/60 Hz. The part carries the designation code 5SY6CC and is listed for mechanical engineering and industry applications.","metaTitle":"Siemens 5SY6210-6CC SENTRON MCB, 2P B-Char 10A, 6kA","metaDescription":"Siemens 5SY6210-6CC SENTRON 2-pole miniature circuit breaker, B-curve, 10 A rated current, 6 kA breaking capacity per EN 60898, 400 V AC. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"36 mm","title":"5SY6210-6CC","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Rated Value":"50/60 Hz","description":"Miniature circuit breaker 400 V 6kA, 2-pole, B, 10 A","Halogen-Free":"Yes","Silicon-Free":"Yes","Mounting type":"Quick assembly system","Number of poles":"2","Type of voltage":"AC","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Degree of pollution":"3","Product designation":"Miniature circuit breaker","Protection class IP":"IP20, with connected conductors","at AC / rated value":"400 V","Overvoltage category":"III","Combined Terminal Top":"Yes","Energy limiting class":"3","Number of width units":"2","Number of poles / Note":"2P","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","Combined Terminal Bottom":"Yes","circuit-breaker / Design":"5SY6CC","Suitability for operation":"Mechanical engineering / industry","Tripping characteristic class":"B","at DC / rated value / maximum":"72 V","acc. to EN 60898 / rated value":"6 kA","Position / of power supply cord":"Any","Product feature / Touch protection":"Yes","Operating current / at AC / rated value":"10 A","Influence of the surrounding temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","at AC / acc. to UL 1077 and CSA C22.2 No.235":"5 kA","Product function / neutral conductor switching":"No","with multi-phase operation / at AC / rated value":"440 V","with single-phase operation / at AC / rated value":"440 V","Mechanical service life (switching cycles) / typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f91c568fd6a2f9555a5ad3fc77c375bd.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=2168&mlfb=5SY6210-6CC"},"ai":{"faq":[{"question":"Where can I buy the 5SY6210-6CC?","answer":"This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."},{"question":"What are the key ratings for this MCB?","answer":"Rated current 10 A, B tripping characteristic, 2-pole, 400 V AC, breaking capacity 6 kA per EN 60898 and 5 kA per UL 1077/CSA C22.2 No. 235."},{"question":"Will the 5SY6210-6CC fit in a panel designed for the 5SY3132-6?","answer":"Both are 2-pole, 36 mm wide SENTRON MCBs with the same DIN-rail mounting and terminal layout, so they share the same panel footprint. However, the 5SY3132-6 has a different tripping characteristic and current rating — verify the BOM specs before substitution."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY6210-6CC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY6210-6CC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}