{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY6413-7","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY6413-7","canonicalUrl":"https://aoctrl.com/siemens/5SY6413-7","factsUrl":"https://aoctrl.com/api/mcp/products/5SY6413-7","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY6413-7, 4-pole miniature circuit breaker, C-curve, 13 A rated, 6 kA (EN 60898) / 15 kA (IEC 60947-2) breaking capacity, IP20.","salesMarkdown":"The Siemens 5SY6413-7 is a SENTRON 4-pole miniature circuit breaker with C-curve tripping, rated 13 A at 35 °C. It carries a dual breaking capacity: 6 kA per EN 60898 and 15 kA per IEC 60947-2 (also 15 kA at DC per IEC 60947-2). That dual rating means it meets the standard for residential/commercial panelboards (EN 60898) while also qualifying for industrial control panels where higher fault current and DC capability are required — one part covers both worlds. Rated current is 13 A at 35 °C, but the breaker is thermally sensitive: it derates to 12.38 A at 40 °C, 12.05 A at 45 °C, 11.73 A at 50 °C, and 11.38 A at 55 °C. Mounting position any, so it fits vertical or horizontal busbars. IP20 with connected conductors — protected against finger touch but not water ingress. Suitable for mechanical engineering and industry per the manufacturer's listing.","metaTitle":"Siemens 5SY6413-7 SENTRON MCB, 4P C-Curve 13A, 6kA/15kA","metaDescription":"Siemens 5SY6413-7 SENTRON 4-pole MCB, C-curve 13A, 6kA (EN 60898) / 15kA (IEC 60947-2). Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"76 mm","Width":"72 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC / EN 60898-1, IEC / EN 60947-2 / UL1077","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"4P","Number Of Poles":"4","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","at AC rated value":"13 A","at DC rated value":"60 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"Yes","at 35 °C rated value":"13 A","at 40 °C rated value":"12.38 A","at 45 °C rated value":"12.05 A","at 50 °C rated value":"11.73 A","at 55 °C rated value":"11.38 A","Energy Limitation Class":"3","Combined Terminal Bottom":"Yes","Suitability For Operation":"Mechanical engineering / industry","Neutral Conductor Switching":"No","Number Of Modular Width Units":"4","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"C","according to EN 60898 rated value":"6 kA","according to IEC 60947-2 rated value":"15 kA","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","Type Of Voltage Of The Operating Voltage":"AC","at DC according to IEC 60947-2 rated value":"15 kA","Value Range Of The Supply Voltage Frequency":"50/60 Hz","operating voltage at DC rated value maximum":"72 V","with multi-phase operation at AC rated value":"440 V","with single-phase operation at AC rated value":"440 V","at AC according to UL 1077 and CSA C22.2 No.235":"5 kA","vibration resistance according to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","supply voltage with single-phase operation at AC rated value":"230 V","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.4 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6345afa99d751baa2569fe5c1e836088.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=500535&mlfb=5SY6413-7","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SY6413-7/alternatives.json"},"ai":{"faq":[{"question":"What is the breaking capacity of the 5SY6413-7?","answer":"It is dual-rated: 6 kA according to EN 60898, and 15 kA according to IEC 60947-2 (AC and DC). The higher IEC rating applies in industrial panels where the fault current is calculated per IEC 60947-2."},{"question":"What is the C-curve tripping characteristic?","answer":"C-curve means the magnetic trip operates at 5 to 10 times the rated current (13 A), so it handles moderate inrush from motor starters and transformers without nuisance tripping, while still protecting against short circuits."},{"question":"Where can I buy the 5SY6413-7?","answer":"The 5SY6413-7 is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY6413-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY6413-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}