{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY6510-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY6510-6","canonicalUrl":"https://aoctrl.com/siemens/5SY6510-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SY6510-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY6510-6, 2-pole (1P+N) miniature circuit breaker, B-curve, 6 kA per IEC 60898-1 / 15 kA per IEC 60947-2, 230 V AC, 60 V DC, 2 MW width, IP20.","salesMarkdown":"## What this MCB does in the panel It switches both phase and neutral, with the neutral pole switching but not protected — a common configuration for single-phase sub-circuits where you want a single-width disconnect on the neutral without an overcurrent element. For a conveyor zone-control panel feeding solenoid valves and photoeyes, B-curve avoids nuisance trips on small transformer inrush while still clearing a hard short fast. The 15 kA rating at 230 V AC gives headroom on most 400/230 V distribution boards — you can place this downstream of a transformer or upstream in a sub-panel without worrying about the interrupting rating being the weak link in the coordination study. Occupies 2 modular width units (36 mm) on a standard DIN rail, with a depth of 76 mm and an installation depth of 70 mm — the extra 6 mm accounts for the terminal screws protruding past the rail. Height is 90 mm. The quick-assembly fastening method means it snaps onto the rail without tools and clips off with a screwdriver slot — no captive screws to lose during panel build. Sealable so the panel builder can lock the toggle position with a wire seal or padlock hasp for lockout/tagout compliance. Dual-certified to IEC 60898-1 and IEC 60947-2 / UL 1077 — covers both the European installation standard and the North American supplementary-protector standard. Halogen-free and silicon-free. Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz — survives the shake of a conveyor drive or compressor skid.","metaTitle":"Siemens 5SY6510-6 SENTRON MCB, 2-Pole B-Curve, 6kA IEC","metaDescription":"Siemens 5SY6510-6 SENTRON miniature circuit breaker, 2-pole 1P+N, B-curve, 6 kA per IEC 60898-1 / 15 kA per IEC 60947-2. Current production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"36 mm","title":"5SY6510-6","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC / EN 60898-1, IEC / EN 60947-2 / UL1077","description":"Miniature circuit breaker 230 V 6kA, 1+N-pole B, 10A, D=70 mm","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","at AC rated value":"230 V","at DC rated value":"60 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"Yes","Energy Limitation Class":"3","Combined Terminal Bottom":"Yes","Suitability For Operation":"Mechanical engineering / industry","Neutral Conductor Switching":"Yes","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"B","according to EN 60898 rated value":"6 kA","according to IEC 60947-2 rated value":"15 kA","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","Type Of Voltage Of The Operating Voltage":"AC","at DC according to IEC 60947-2 rated value":"15 kA","Value Range Of The Supply Voltage Frequency":"50/60 Hz","operating voltage at DC rated value maximum":"72 V","with single-phase operation at AC rated value":"250 V","at AC according to UL 1077 and CSA C22.2 No.235":"5 kA","vibration resistance according to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","supply voltage with single-phase operation at AC rated value":"230 V","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.3 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$13.97","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9b375270422d3c4b45d594515196e573.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=422729&mlfb=5SY6510-6"},"ai":{"faq":[{"question":"What compliance documentation does Siemens provide for 5SY6510-6?","answer":"The 5SY6510-6 is certified to IEC 60898-1, IEC 60947-2, UL 1077, and CSA C22.2 No.235. It is halogen-free and silicon-free. Standard documentation includes the declaration of conformity, CE marking, and UKCA marking — available on request with the RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY6510-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY6510-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}