{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY7113-7CC","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY7113-7CC","canonicalUrl":"https://aoctrl.com/siemens/5SY7113-7CC","factsUrl":"https://aoctrl.com/api/mcp/products/5SY7113-7CC","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY7113-7CC miniature circuit breaker, 1-pole, C tripping characteristic, 25 kA per IEC 60947-2, 400 V AC, 18 mm wide, 1 MW.","salesMarkdown":"The Siemens SENTRON 5SY7113-7CC is a 1-pole miniature circuit breaker with a C tripping characteristic, rated 400 V AC and 25 kA per IEC 60947-2. Under UL 1077 and CSA C22.2 No. 235, the rating is 5 kA — a different standard, not a derating; verify which applies to your installation jurisdiction. The 18 mm width occupies exactly one modular unit on a DIN rail, so it fits standard 18 mm-per-pole panel layouts. Halogen-free and silicon-free construction, which matters in clean-room or semiconductor-adjacent installations where outgassing can contaminate optics or sensitive surfaces. Rated for ambient temperature from -40 °C to 75 °C, with derating on humidity: max 95% RH at 55 °C, tapering to 35% RH at 75 °C. That covers unheated outdoor enclosures and hot machine cabinets. Vibration resistance per IEC 60068-2-6: ±1 mm at 5 to 25 Hz, 50 m/s² at 25 to 150 Hz — adequate for industrial machinery but not for direct mounting on high-vibration equipment without isolation. Snap-on DIN rail mounting via the quick assembly system. Combined terminal top and bottom accept both busbar and conductor connections — no need to remove the busbar to wire the load side.","metaTitle":"Siemens 5SY7113-7CC SENTRON MCB, C-Curve, 1-Pole, 25 kA IEC","metaDescription":"Siemens SENTRON 5SY7113-7CC miniature circuit breaker, 1-pole, C tripping characteristic, 25 kA per IEC 60947-2, 400 V AC, 18 mm wide. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SY7113-7CC","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Miniature circuit breaker 230/400 V 15kA, 1-pole, C, 13A","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P","Number Of Poles":"1","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","at AC rated value":"400 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"Yes","Combined Terminal Bottom":"Yes","Suitability For Operation":"Mechanical engineering / industry","Neutral Conductor Switching":"No","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"C","according to IEC 60947-2 rated value":"25 kA","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","Type Of Voltage Of The Operating Voltage":"AC","Value Range Of The Supply Voltage Frequency":"50/60 Hz","operating voltage at DC rated value maximum":"72 V","with multi-phase operation at AC rated value":"440 V","with single-phase operation at AC rated value":"440 V","at AC according to UL 1077 and CSA C22.2 No.235":"5 kA","vibration resistance according to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","supply voltage with single-phase operation at AC rated value":"230 V","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.4 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/997fc1f409da345ffd93929987d5b03a.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=390790&mlfb=5SY7113-7CC"},"ai":{"faq":[{"question":"How do I get current pricing and availability for 5SY7113-7CC?","answer":"Submit an RFQ through the distributor. Availability and current pricing are confirmed at quote time through independent distribution channels. No stock count or price is published here."},{"question":"Will 5SY7113-7CC drop into a panel specified around 5SY4101-7CV?","answer":"Both are 1-pole SENTRON MCBs with the same 18 mm width and DIN-rail footprint, so mechanical fit is identical. The 5SY7113-7CC carries a C-curve and 25 kA IEC breaking capacity; the 5SY4101-7CV has a different characteristic and rating. Verify the tripping curve and interrupting rating match your coordination study before swapping."},{"question":"What compliance documentation does Siemens provide for 5SY7113-7CC?","answer":"The part is rated per IEC 60947-2 (25 kA) and UL 1077 / CSA C22.2 No. 235 (5 kA). It is halogen-free and silicon-free. Standard Siemens declarations of conformity (CE, UKCA) and material compliance (RoHS, REACH) are available through the manufacturer's documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY7113-7CC","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY7113-7CC when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}