{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY7132-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY7132-6","canonicalUrl":"https://aoctrl.com/siemens/5SY7132-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SY7132-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY7132-6, 1-pole miniature circuit breaker, B characteristic, 15 kA (EN 60898) / 25 kA (IEC 60947-2), 400 V AC, 1 MW unit.","salesMarkdown":"It's rated 15 kA breaking capacity per EN 60898-1 and 25 kA per IEC 60947-2, so in a panel you get the higher fault-interrupt rating for industrial coordination studies while still meeting the residential/commercial standard. The B curve means it trips at 3–5× rated current — good for resistive or lighting loads where you don't want nuisance trips from motor inrush. Mounts in any position — no derating needed for horizontal or upside-down orientation. Combined terminal top and bottom means you can feed from either direction without swapping the breaker. Certified to IEC/EN 60898-1 and IEC/EN 60947-2 for the 15/25 kA ratings respectively, plus UL 1077 and CSA C22.2 No. 235 for the 5 kA North American supplementary protector rating. Energy limitation class 3 — fast enough for most downstream coordination needs. Supply frequency 50/60 Hz, operating voltage 400 V AC single-phase or 440 V multi-phase.","metaTitle":"Siemens 5SY7132-6 SENTRON MCB, 1P B-Curve, 15/25 kA","metaDescription":"Siemens 5SY7132-6 SENTRON miniature circuit breaker, 1-pole, B characteristic, 15 kA (EN 60898) / 25 kA (IEC 60947-2). Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"18 mm","title":"5SY7132-6","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC / EN 60898-1, IEC / EN 60947-2 / UL1077","description":"Miniature circuit breaker 230/400 V 15kA, 1-pole, B, 32 A, D=70 mm","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P","Number Of Poles":"1","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","at AC rated value":"400 V","at DC rated value":"60 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"Yes","Energy Limitation Class":"3","Combined Terminal Bottom":"Yes","Suitability For Operation":"Mechanical engineering / industry","Neutral Conductor Switching":"No","Number Of Modular Width Units":"1","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"B","according to EN 60898 rated value":"15 kA","according to IEC 60947-2 rated value":"25 kA","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","Type Of Voltage Of The Operating Voltage":"AC","at DC according to IEC 60947-2 rated value":"15 kA","Value Range Of The Supply Voltage Frequency":"50/60 Hz","operating voltage at DC rated value maximum":"72 V","with multi-phase operation at AC rated value":"440 V","with single-phase operation at AC rated value":"440 V","at AC according to UL 1077 and CSA C22.2 No.235":"5 kA","vibration resistance according to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","supply voltage with single-phase operation at AC rated value":"230 V","power loss [W] for rated value of the current at AC in hot operating state per pole":"2.6 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e1e5a026980d06a9fcdc4b4b1e5bce74.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=483292&mlfb=5SY7132-6"},"ai":{"faq":[{"question":"Where can I buy 5SY7132-6?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time."},{"question":"Will 5SY7132-6 drop into a panel specified around 5SY4116-6CC without rewiring?","answer":"Both are 1-pole SENTRON MCBs in 18 mm width with the same DIN-rail mounting, so the mechanical fit is identical. The 5SY7132-6 carries a B curve and higher breaking capacities (15/25 kA vs whatever the 5SY4116-6CC is rated); verify the tripping characteristic matches your coordination study before swapping."},{"question":"What compliance documentation does Siemens provide for 5SY7132-6?","answer":"The part carries IEC/EN 60898-1, IEC/EN 60947-2, UL 1077, and CSA C22.2 No. 235 certifications. It's halogen-free and silicon-free. Standard Siemens declaration of conformity and CE/UKCA documentation is available with the shipment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY7132-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY7132-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}