{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY7213-6","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY7213-6","canonicalUrl":"https://aoctrl.com/siemens/5SY7213-6","factsUrl":"https://aoctrl.com/api/mcp/products/5SY7213-6","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON miniature circuit breaker, 5SY7213-6, 2-pole, B characteristic, 15 kA (EN 60898) / 25 kA (IEC 60947-2), 400 V AC.","salesMarkdown":"## Siemens 5SY7213-6 SENTRON MCB — 2-pole B-curve for industrial panel protection Breaking capacity is 15 kA per EN 60898-1 and 25 kA per IEC 60947-2, with a 5 kA rating under UL 1077 / CSA C22.2 No. 235 for North American panels. ## Breaking capacity and standard compliance This breaker is certified to both IEC/EN 60898-1 and IEC/EN 60947-2, plus UL 1077. The 15 kA rating under 60898-1 covers the residential and light commercial duty cycle; the 25 kA rating under 60947-2 is the figure that matters for industrial coordination studies where higher fault current is expected. At DC (60–72 V) it interrupts 15 kA per IEC 60947-2. The 5 kA UL 1077 rating means it qualifies as a supplementary protector in North American control panels — not a branch-circuit rated device under UL 489, so verify your local code before specifying it as the sole overcurrent device on a feeder. ## Environmental and installation notes Rated for ambient temperatures from -40 °C to 75 °C, with humidity derating above 55 °C (max 95% RH at 55 °C, tapering to 35% at 75 °C).","metaTitle":"Siemens 5SY7213-6 SENTRON MCB, 2P B-Curve, 15/25 kA","metaDescription":"Siemens 5SY7213-6 SENTRON miniature circuit breaker, 2-pole, B characteristic, 15 kA (EN 60898) / 25 kA (IEC 60947-2). Active production, sourced to order. Quoted against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["2-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"36 mm","title":"5SY7213-6","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC / EN 60898-1, IEC / EN 60947-2 / UL1077","description":"Miniature circuit breaker 400 V 15kA, 2-pole, B, 13 A, D=70 mm","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"2P","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","at AC rated value":"400 V","at DC rated value":"60 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"Yes","Energy Limitation Class":"3","Combined Terminal Bottom":"Yes","Suitability For Operation":"Mechanical engineering / industry","Neutral Conductor Switching":"No","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"B","according to EN 60898 rated value":"15 kA","according to IEC 60947-2 rated value":"25 kA","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","Type Of Voltage Of The Operating Voltage":"AC","at DC according to IEC 60947-2 rated value":"15 kA","Value Range Of The Supply Voltage Frequency":"50/60 Hz","operating voltage at DC rated value maximum":"72 V","with multi-phase operation at AC rated value":"440 V","with single-phase operation at AC rated value":"440 V","at AC according to UL 1077 and CSA C22.2 No.235":"5 kA","vibration resistance according to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","supply voltage with single-phase operation at AC rated value":"230 V","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.7 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4b90e321a8311c371c7b2063e016b988.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=426559&mlfb=5SY7213-6"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SY7213-6?","answer":"15 kA per EN 60898-1, 25 kA per IEC 60947-2 at 400 V AC, and 15 kA at 60–72 V DC per IEC 60947-2. Under UL 1077 it is rated 5 kA."},{"question":"Where can I buy 5SY7213-6?","answer":"The part is sourced to order against an RFQ through independent distribution. Submit a request for quote — availability and current pricing are confirmed at quote time."},{"question":"What compliance documentation does the 5SY7213-6 carry?","answer":"It is certified to IEC/EN 60898-1, IEC/EN 60947-2, and UL 1077 / CSA C22.2 No. 235. The housing is halogen-free and silicon-free."},{"question":"Will 5SY7213-6 drop into a panel specified for 5SY7210-7CC?","answer":"Both are 2-pole SENTRON MCBs on a 36 mm footprint with the same DIN-rail mounting, so the mechanical fit is identical. The difference is the tripping characteristic: 5SY7213-6 is B-curve (3–5× In), while 5SY7210-7CC carries a different characteristic. Verify the required curve for your circuit before substituting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY7213-6","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY7213-6 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}