{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY7416-7","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY7416-7","canonicalUrl":"https://aoctrl.com/siemens/5SY7416-7","factsUrl":"https://aoctrl.com/api/mcp/products/5SY7416-7","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY7416-7, 4-pole miniature circuit breaker, C tripping characteristic, 15 kA (EN 60898-1) / 25 kA (IEC 60947-2) breaking capacity, 400 V AC, halogen-free.","salesMarkdown":"## Siemens 5SY7416-7 — 4-pole C-curve MCB for panel builders The Siemens 5SY7416-7 is a 4-pole miniature circuit breaker from the SENTRON series, with a C tripping characteristic and a rated breaking capacity of 15 kA per EN 60898-1 and 25 kA per IEC 60947-2. It's rated for 400 V AC (440 V multi- or single-phase) and 60 V DC (72 V max). The quick-assembly system and combined top/bottom terminals simplify panel wiring. ## Breaking capacity — what the dual rating means for your panel 15 kA under EN 60898-1; 25 kA under IEC 60947-2 at 400 V AC. Under UL 1077, listed at 5 kA. For DC circuits, it's rated 15 kA at 60 V (72 V max) per IEC 60947-2. That's a solid figure for DC bus protection in drives or battery-backed control circuits, but watch the voltage — DC arcs are harder to extinguish, and this breaker's voltage limit is lower than its AC capability. Certified to IEC / EN 60898-1 and IEC / EN 60947-2, plus UL 1077. Halogen-free and silicon-free. Sealable. That's a factor in selective coordination: a Class 3 MCB upstream of a Class 3 MCB can coordinate without cascading, provided the ratio of ratings is adequate.","metaTitle":"Siemens 5SY7416-7 SENTRON MCB, 4P C-Curve, 15/25 kA","metaDescription":"Siemens 5SY7416-7 SENTRON 4-pole MCB, C characteristic, 15 kA (EN 60898) / 25 kA (IEC 60947-2) breaking capacity. Active production, sourced to order. Request quote.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Miniature Circuit Breakers (MCB)"],"specifications":{"Depth":"76 mm","Width":"72 mm","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC / EN 60898-1, IEC / EN 60947-2 / UL1077","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"4P","Number Of Poles":"4","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","at AC rated value":"400 V","at DC rated value":"60 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"Yes","Energy Limitation Class":"3","Combined Terminal Bottom":"Yes","Suitability For Operation":"Mechanical engineering / industry","Neutral Conductor Switching":"No","Number Of Modular Width Units":"4","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"C","according to EN 60898 rated value":"15 kA","according to IEC 60947-2 rated value":"25 kA","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","Type Of Voltage Of The Operating Voltage":"AC","at DC according to IEC 60947-2 rated value":"15 kA","Value Range Of The Supply Voltage Frequency":"50/60 Hz","operating voltage at DC rated value maximum":"72 V","with multi-phase operation at AC rated value":"440 V","with single-phase operation at AC rated value":"440 V","at AC according to UL 1077 and CSA C22.2 No.235":"5 kA","vibration resistance according to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","supply voltage with single-phase operation at AC rated value":"230 V","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.6 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5ea1a64a7c5847517fd5c336c67e625e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=352184&mlfb=5SY7416-7","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SY7416-7/alternatives.json"},"ai":{"faq":[{"question":"Will 5SY7416-7 drop into a panel specified around 5SY4140-7 without rewiring?","answer":"Both are 4-pole SENTRON MCBs with C-curve and similar breaking capacities, but the 5SY7416-7 has a different order code and may differ in accessory compatibility or internal construction. Physically both occupy 4 modular units (72 mm) on DIN rail, so the footprint is the same — but verify the terminal arrangement and any auxiliary contact fit before assuming a drop-in swap."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY7416-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY7416-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}