{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY7510-7","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY7510-7","canonicalUrl":"https://aoctrl.com/siemens/5SY7510-7","factsUrl":"https://aoctrl.com/api/mcp/products/5SY7510-7","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON, 5SY7510-7, miniature circuit breaker, 2-pole (1P+N), C characteristic, 15 kA (EN 60898) / 30 kA (IEC 60947-2), 230 V AC, 36 mm wide.","salesMarkdown":"## Integrator's spec recap — 5SY7510-7 That neutral-switching feature matters for installations where an isolated neutral is required after the breaker opens, typical in single-phase sub-distribution or machine supply panels where you want both conductors positively disconnected. The breaker is rated for 230 V AC and carries a 15 kA breaking capacity per EN 60898, with a higher 30 kA rating per IEC 60947-2 for industrial panel duty where the prospective fault current is higher. For DC circuits it is rated 60 V at 15 kA per IEC 60947-2. Certified to IEC / EN 60898-1 and IEC / EN 60947-2, plus UL 1077. Halogen-free and silicon-free construction. Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz. The sealable design allows lockout-tagout application. Energy limitation class 3.","metaTitle":"Siemens 5SY7510-7 MCB, C-curve 2-pole 1P+N, 15/30 kA","metaDescription":"Siemens SENTRON 5SY7510-7 miniature circuit breaker, 2-pole (1P+N), C characteristic, 15 kA per EN 60898, 30 kA per IEC 60947-2. Current production. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"36 mm","title":"5SY7510-7","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC / EN 60898-1, IEC / EN 60947-2 / UL1077","description":"Miniature circuit breaker 230 V 15kA, 1+N-pole, C, 10A, D=70 mm","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"1P+N","Number Of Poles":"2","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","at AC rated value":"230 V","at DC rated value":"60 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"Yes","Energy Limitation Class":"3","Combined Terminal Bottom":"Yes","Suitability For Operation":"Mechanical engineering / industry","Neutral Conductor Switching":"Yes","Number Of Modular Width Units":"2","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"C","according to EN 60898 rated value":"15 kA","according to IEC 60947-2 rated value":"30 kA","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","Type Of Voltage Of The Operating Voltage":"AC","at DC according to IEC 60947-2 rated value":"15 kA","Value Range Of The Supply Voltage Frequency":"50/60 Hz","operating voltage at DC rated value maximum":"72 V","with single-phase operation at AC rated value":"250 V","at AC according to UL 1077 and CSA C22.2 No.235":"5 kA","vibration resistance according to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","supply voltage with single-phase operation at AC rated value":"230 V","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.1 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/28d57a55582c6b21f3f6807376876906.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=152467&mlfb=5SY7510-7"},"ai":{"faq":[{"question":"What is the breaking capacity of 5SY7510-7?","answer":"15 kA per EN 60898 and 30 kA per IEC 60947-2. At DC (60 V) it is rated 15 kA per IEC 60947-2. Under UL 1077 it carries 5 kA."},{"question":"Will 5SY7510-7 drop into a panel specified around 5SY4140-7 without rewiring?","answer":"The 5SY7510-7 is a 2-pole (1P+N) breaker with neutral switching, while the 5SY4140-7 is a 1-pole design. Both share the same 36 mm width per pole (2 MW for the 2-pole) and DIN-rail mounting, but the neutral-switching requirement and pole count differ — verify the panel's wiring diagram before substituting."},{"question":"Where can I buy 5SY7510-7 and how is it quoted?","answer":"Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY7510-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY7510-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}