{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY7513-8","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY7513-8","canonicalUrl":"https://aoctrl.com/siemens/5SY7513-8","factsUrl":"https://aoctrl.com/api/mcp/products/5SY7513-8","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY7 miniature circuit breaker, 2-pole 1P+N, 13 A rated current, D tripping characteristic, 230 V AC, 15 kA (EN 60898) / 25 kA (IEC 60947-2) breaking capacity.","salesMarkdown":"The Siemens 5SY7513-8 is a 2-pole (1P+N) SENTRON miniature circuit breaker rated 13 A with a D tripping characteristic, designed for 230 V AC circuits and suitable for DC applications up to 72 V. It carries a 15 kA breaking capacity per EN 60898 and 25 kA per IEC 60947-2, with a UL 1077 / CSA C22.2 No. 235 rating of 5 kA at AC — giving the site electrical engineer headroom for high-fault panels where selectivity and SCCR coordination matter. The 36 mm width (2 width units) fits standard enclosure cutouts. IP20 with connected conductors; sealable and touch-protected per the product features.","metaTitle":"Siemens 5SY7513-8 SENTRON MCB, 2-pole 1P+N, 13 A D-curve, 15","metaDescription":"Siemens 5SY7513-8 SENTRON miniature circuit breaker, 2-pole 1P+N, 13 A, D tripping characteristic, 15 kA (EN 60898) / 25 kA (IEC 60947-2), 230 V AC, 72 V DC max. Current production","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Solid":"0.75 ... 35 mm²","Width":"36 mm","Height":"90 mm","Sealable":"Yes","Stranded":"0.75 ... 35 mm²","Rated Value":"50/60 Hz","Halogen-Free":"Yes","Silicon-Free":"Yes","Wertebereich":"-40 ... +70 °C","Mounting type":"Quick assembly system","Number of poles":"2","Type of voltage":"AC","lifecycle_stage":"current","Mounting position":"any","Installation depth":"70 mm","Product brand name":"SENTRON","Ambient temperature":"-40 ... +75 °C","Product designation":"Miniature circuit breaker","Protection class IP":"IP20, with connected conductors","at AC / rated value":"230 V","Overvoltage category":"III","Combined Terminal Top":"Yes","Number of width units":"2","Number of poles / Note":"1P+N","acc. to DIN EN 61346-2":"F","acc. to DIN EN 81346-2":"F","Combined Terminal Bottom":"Yes","circuit-breaker / Design":"5SY7","Suitability for operation":"Mechanical engineering / industry","Current / at AC / rated value":"13 A","Tripping characteristic class":"D","at DC / rated value / maximum":"72 V","acc. to EN 60898 / rated value":"15 kA","Position / of power supply cord":"Any","acc. to IEC 60947-2 / rated value":"25 kA","Product feature / Touch protection":"Yes","Influence of the surrounding temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","at DC / acc. to IEC 60947-2 / rated value":"15 kA","at AC / acc. to UL 1077 and CSA C22.2 No.235":"5 kA","Tightening torque / with screw-type terminals":"2.5 ... 3.5 N·m","Product function / neutral conductor switching":"Yes","with single-phase operation / at AC / rated value":"250 V","Mechanical service life (switching cycles) / typical":"10 000","Tightening torque [lbf·in] / with screw-type terminals":"22 ... 31 lbf·in","AWG number / as coded connectable conductor cross section":"18 ... 4"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4b2670b9b51be02e7bb314f54ecd44cd.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=108380&mlfb=5SY7513-8","alternativesUrl":"https://aoctrl.com/api/mcp/products/5SY7513-8/alternatives.json"},"ai":{"faq":[{"question":"Who supplies 5SY7513-8 and how is it quoted for volume purchases?","answer":"This part is supplied through the authorized Siemens channel. For volume or BOM-line requirements, submit an RFQ — availability and current pricing are confirmed at quote time."},{"question":"What is 5SY7513-8's listed depth?","answer":"The overall depth is 76 mm; installation depth is 70 mm."},{"question":"What conductor sizes does 5SY7513-8 accept?","answer":"Both solid and stranded conductors from 0.75 to 35 mm²."},{"question":"What compliance documentation is available for 5SY7513-8?","answer":"The breaker carries approvals per EN 60898 (15 kA), IEC 60947-2 (25 kA), and UL 1077 / CSA C22.2 No. 235 (5 kA). It is halogen-free and silicon-free. Standard RoHS/REACH declarations are provided with the shipment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY7513-8","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY7513-8 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}