{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY7610-7","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY7610-7","canonicalUrl":"https://aoctrl.com/siemens/5SY7610-7","factsUrl":"https://aoctrl.com/api/mcp/products/5SY7610-7","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY7610-7, 4-pole (3P+N) miniature circuit breaker, C-curve, 15 kA per EN 60898-1 / 30 kA per IEC 60947-2, 400 V AC, 4 MW DIN-rail mount.","salesMarkdown":"## What this 4-pole MCB brings to the panel The Siemens 5SY7610-7 is a 4-pole (3P+N) SENTRON miniature circuit breaker with a C-curve trip characteristic, meaning it's built for moderate inrush loads like motor starters and small transformers where the magnetic trip kicks in at 5–10× rated current. The neutral pole is switched, so you get full isolation on all four poles in a single 4-module-width package — no separate neutral link needed. Breaking capacity is dual-rated: 15 kA per EN 60898-1 and 30 kA per IEC 60947-2, with a DC rating of 15 kA at 60 V per IEC 60947-2 and 5 kA per UL 1077 / CSA C22.2 No.235. DC side is rated at 60 V, max 72 V. Frequency is 50/60 Hz. ## Standards and compliance — what the approvals mean This breaker carries triple certification: IEC / EN 60898-1 (the residential and light-commercial standard for MCBs), IEC / EN 60947-2 (the industrial standard for circuit breakers), and UL 1077 (the supplementary protector standard for North America). That means it's accepted in European, UK, and North American panels — one part number covers multiple regulatory jurisdictions. Halogen-free and silicon-free construction reduces toxic smoke and corrosive byproducts in a fault event — relevant for panels in occupied spaces or sensitive electronics areas. The sealable option lets you lock the toggle position to prevent unauthorized reset after a trip. ## Mounting and integration — DIN-rail fit That 72 mm width equals 4 modular units — a standard 4-pole MCB footprint that drops into any 35 mm DIN-rail panel without surprises. IP20 protection with connected conductors — standard for inside the enclosure; no special sealing required. Combined terminals on both top and bottom accept supply from either end, so you can bus the line side without reconfiguring the breaker.","metaTitle":"Siemens 5SY7610-7 SENTRON MCB, 4P C-curve, 15/30 kA","metaDescription":"Siemens 5SY7610-7 SENTRON miniature circuit breaker, 4-pole 3P+N, C-curve, 15 kA (EN 60898) / 30 kA (IEC 60947-2). Active production. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["4-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"72 mm","title":"5SY7610-7","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","Standard":"IEC / EN 60898-1, IEC / EN 60947-2 / UL1077","description":"Miniature circuit breaker 400 V 15kA, 3+N-pole, C, 10A, D=70 mm","Halogen-Free":"Yes","Silicon-Free":"Yes","Design Of Pole":"3P+N","Number Of Poles":"4","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","at AC rated value":"400 V","at DC rated value":"60 V","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"Yes","Energy Limitation Class":"3","Combined Terminal Bottom":"Yes","Suitability For Operation":"Mechanical engineering / industry","Neutral Conductor Switching":"Yes","Number Of Modular Width Units":"4","Position Of Power Supply Cord":"Any","Tripping Characteristic Class":"C","according to EN 60898 rated value":"15 kA","according to IEC 60947-2 rated value":"30 kA","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","Type Of Voltage Of The Operating Voltage":"AC","at DC according to IEC 60947-2 rated value":"15 kA","Value Range Of The Supply Voltage Frequency":"50/60 Hz","operating voltage at DC rated value maximum":"72 V","with multi-phase operation at AC rated value":"440 V","with single-phase operation at AC rated value":"440 V","at AC according to UL 1077 and CSA C22.2 No.235":"5 kA","vibration resistance according to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","Mechanical Service Life (Operating Cycles) Typical":"10 000","Product Extension Installable Supplementary Devices":"Yes","supply voltage with single-phase operation at AC rated value":"230 V","power loss [W] for rated value of the current at AC in hot operating state per pole":"1.1 W"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9e6a893fd83ab450f8b6d65fdfb33f39.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=108937&mlfb=5SY7610-7"},"ai":{"faq":[{"question":"What is the breaking capacity of the 5SY7610-7?","answer":"The 5SY7610-7 is dual-rated: 15 kA per EN 60898-1 and 30 kA per IEC 60947-2 at 400 V AC. For DC circuits it's rated 15 kA at 60 V per IEC 60947-2, and 5 kA per UL 1077."},{"question":"What standards does the 5SY7610-7 comply with?","answer":"It complies with IEC / EN 60898-1, IEC / EN 60947-2, and UL 1077 / CSA C22.2 No.235. It is also halogen-free and silicon-free, with pollution degree 3 and overvoltage category III ratings."},{"question":"Where can I buy the 5SY7610-7 and get current pricing?","answer":"The 5SY7610-7 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time."},{"question":"Will the 5SY7610-7 drop into a panel specified for the 5SY4140-7?","answer":"Both are 4-pole SENTRON MCBs on the same DIN-rail footprint, so the mechanical fit is the same. The key difference is the 5SY7610-7 carries a C-curve versus whatever curve the 5SY4140-7 variant specifies — verify the trip characteristic matches your coordination study before swapping."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY7610-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY7610-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}