{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"5SY8540-7","brand":"Siemens","brandSlug":"siemens","productSlug":"5SY8540-7","canonicalUrl":"https://aoctrl.com/siemens/5SY8540-7","factsUrl":"https://aoctrl.com/api/mcp/products/5SY8540-7","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SENTRON 5SY8540-7 miniature circuit breaker, 2-pole (1P+N), C characteristic, 40 A rated current at 45 °C, 25 kA breaking capacity per IEC 60947-2, 230 V AC, 50/60 Hz.","salesMarkdown":"## What it is and what it does The Siemens 5SY8540-7 is a SENTRON miniature circuit breaker (MCB) with two poles configured as 1P+N — it switches the line and the neutral together, which matters for circuits where the neutral must be isolated on a fault. Rated 40 A at 45 °C with a C tripping characteristic, it handles moderate inrush from motor starters or lighting banks without nuisance trips, while still clearing overloads and short-circuits. The breaking capacity is 25 kA per IEC 60947-2 at 230 V AC, and 15 kA for DC circuits per the same standard; under UL 1077 it's rated 5 kA. ## Where it fits Two modular-width units (36 mm wide) snap onto a DIN rail; mounting position is any, and installation depth is 70 mm plus the breaker body depth of 76 mm. IP20 with connected conductors — fine inside a panel, not for washdown or outdoor exposure. Terminals accept top and bottom combined entry, and the unit is sealable for tamper-proofing after commissioning. ## What the ratings mean for a panel The 25 kA IEC breaking capacity at 230 V AC gives headroom on most commercial and light industrial panels where the prospective short-circuit current stays under that level; the 5 kA UL 1077 rating tells you it's accepted in North American supplementary-protection applications. C-curve means magnetic trip between 5 and 10 times In. Temperature derating is built in: 40 A at 45 °C, 39 A at 50 °C, 38 A at 55 °C — if your panel ambient runs hot, factor that down. Rated for overvoltage category III and pollution degree 3, so it's suited for fixed installations inside an enclosure, not for outdoor or wet locations. Halogen-free and silicon-free construction — relevant if the panel is in a clean room or a zone with sensitive electronics where outgassing matters.","metaTitle":"Siemens 5SY8540-7 SENTRON MCB, 2-Pole C 40 A, 25 kA","metaDescription":"Siemens 5SY8540-7 SENTRON miniature circuit breaker, 2-pole 1P+N, C-curve 40 A, 25 kA IEC breaking capacity, 230 V AC, IP20. Current production, available to order. Sourced and quo","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["1-Pole MCB (DIN Rail)"],"specifications":{"Depth":"76 mm","Width":"36 mm","title":"5SY8540-7","Height":"90 mm","Maximum":"75 °C","Minimum":"-40 °C","Sealable":"Yes","description":"Miniature circuit breaker 230 V D=70 mm 25 kA according to EN 60947-2, 1P+N, C40","Halogen-Free":"Yes","Silicon-Free":"Yes","Number Of Poles":"2","Type Of Voltage":"AC","lifecycle_stage":"current","Fastening Method":"Quick assembly system","Mounting Position":"any","Installation Depth":"70 mm","Product Brand Name":"SENTRON","Degree Of Pollution":"3","Product Designation":"Miniature circuit breaker","acc. to IEC 81346-2":"F","at AC / rated value":"230 V","protection class IP":"IP20, with connected conductors","Overvoltage Category":"III","Combined Terminal Top":"Yes","Number Of Poles / Note":"1P+N","acc. to DIN EN 61346-2":"F","at 45 °C / rated value":"40 A","at 50 °C / rated value":"39 A","at 55 °C / rated value":"37.96 A","Combined Terminal Bottom":"Yes","Suitability For Operation":"Mechanical engineering / industry","Number Of Modular Width Units":"2","Tripping Characteristic Class":"C","Position / Of Power Supply Cord":"Any","acc. to IEC 60947-2 / rated value":"25 kA","Product Feature / Touch Protection":"Yes","Supply Voltage Frequency / Rated Value":"50/60 Hz","Influence Of The Surrounding Temperature":"max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C","at DC / acc. to IEC 60947-2 / rated value":"15 kA","at AC / acc. to UL 1077 and CSA C22.2 No.235":"5 kA","vibration resistance / acc. to IEC 60068-2-6":"±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz","Product Function / Neutral Conductor Switching":"Yes","operating voltage / at DC / rated value / maximum":"72 V","with single-phase operation / at AC / rated value":"250 V","Mechanical Service Life (Operating Cycles) / Typical":"10 000"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/29f5a3f2f119a13d523e0342c87e9702.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=483229&mlfb=5SY8540-7"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/5SY8540-7","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/5SY8540-7 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}