{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"60387","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"60387","canonicalUrl":"https://aoctrl.com/schneider/60387","factsUrl":"https://aoctrl.com/api/mcp/products/60387","rawCanonicalId":null},"summary":{"shortDescription":"Multi9 - C60 UL489 - MCB - 3P - 3 A - D Curve - 240 V - 10 kA - tunnel/ring","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Color":"Gray","Depth":"2.9 in (73 mm)","Range":"Multi9","Width":"2.1 in (54 mm)","Category":"00915-C60N MINIATURE CIRCUIT BREAKER-UL489","Standards":"GB 14048.2 EN/IEC 60947-2 UL 489 CSA C22.2 No 5","Curve code":"D","9 Mm Pitches":"6","Control Type":"Toggle","Network type":"AC","Product name":"Multi9 C60","Mounting Mode":"Clip-on","Tropicalisation":"2 IEC 60068-1","lifecycle_stage":"unknown","Limitation class":"3 EN/IEC 60947-2","Local signalling":"ON/OFF indication","Mounting Support":"DIN rail","Pollution degree":"3 EN/IEC 60947-2","Breaking capacity":"6 kA Icu 440 V AC EN/IEC 60947-2 10 kA Icu 415 V AC EN/IEC 60947-2 20 kA Icu 240 V AC EN/IEC 60947-2 6 kA Icu 440 V AC GB 14048.2 10 kA Icu 415 V AC GB 14048.2 20 kA Icu 240 V AC GB 14048.2 10 kA AIR 240 V AC UL 489 10 kA AIR 240 V AC CSA C22.2 No 5.2","Device short name":"C60 UL489","Network Frequency":"50/60 Hz","Poles description":"3P","Relative humidity":"95 % 131 °F (55 °C)","Tightening torque":"22.1 lbf.in (2.5 N.m) top 17.7 lbf.in (2 N.m) bottom","Device Application":"Distribution","Line Rated Current":"3 A 77 °F (25 °C)","Operating altitude":"6561.68 ft (2000 m)","Overvoltage category":"IV","Trip unit technology":"Thermal-magnetic","Electrical durability":"10000 cycles","Mechanical durability":"20000 cycles","Nbr. of units in pkg.":"1","Wire stripping length":"0.6 in (14 mm) for top connection","Connections - terminals":"Ring terminal bottom) Tunnel type terminal top) 0.004...0.04 in² (2.5...25 mm²) AWG 14...AWG 4) - rigid","IP degree of protection":"IP40 (modular enclosure) conforming to IEC 60529 IP10 conforming to IEC 60529","Magnetic tripping limit":"12 x In +/- 20 % AC","Provision for padlocking":"Padlockable","Number of protected poles":"3","Product or Component Type":"Miniature circuit-breaker","Suitability for isolation":"Yes EN/IEC 60947-2","Contact position indicator":"Yes","[Ui] rated insulation voltage":"500 V AC EN/IEC 60947-2","[Ue] rated operational voltage":"415 V AC 240 V AC 440 V AC","Ambient Air Temperature for Storage":"-40...176 °F (-40...80 °C)","Ambient air temperature for operation":"-22...158 °F (-30...70 °C)","[Uimp] rated impulse withstand voltage":"6 kVEN/IEC 60947-2"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/60387/multi9-c60-ul489-mcb-3p-3-a-d-curve-240-v-10-ka-tunnel-ring/","alternativesUrl":"https://aoctrl.com/api/mcp/products/60387/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/60387","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/60387 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}