{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1010-1AU00-4AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1010-1AU00-4AA0","canonicalUrl":"https://aoctrl.com/siemens/6AG1010-1AU00-4AA0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1010-1AU00-4AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 6AG1010-1AU00-4AA0 PLC, 4 digital inputs, relay output, 110-240 VAC 50/60 Hz, screw and snap-on mounting, 45 x 111 x 124 mm.","salesMarkdown":"## What this PLC handles at the panel The 6AG1010-1AU00-4AA0: Rated supply 110-240 VAC at 50/60 Hz, so it runs straight off a standard control transformer without a separate 24 VDC power supply — one less rail to wire. Four digital inputs and a relay output with current ratings from 0.25 A at 125 VDC up to 6 A at 120 VAC, covering pilot-duty solenoids, contactor coils, and indicator loads in a small machine section. ## Wiring and environment Terminals accept 1x 0.5-4.0 mm² or 2x 0.5-2.5 mm² solid wire — enough for a daisy-chained supply or dual-signal return without a separate junction point. ## Built-in control functions Includes direct start, reverse starting, Dahlander circuit, valve control, slide control, and current detection — the logic for a reversing motor or a two-speed winding is already in the firmware, no extra ladder blocks needed. Test function and I&M3 comment support mean a technician can force outputs and read the module identity over the bus during commissioning without a laptop at the cabinet.","metaTitle":"Siemens 6AG1010-1AU00-4AA0 PLC, 4 DI, Relay Out, 110-240 VAC","metaDescription":"Siemens 6AG1010-1AU00-4AA0 PLC with 4 digital inputs, relay output, rated 110-240 VAC 50/60 Hz. Current lifecycle active. Quoted to order. Request RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Depth":"124 mm","Solid":"1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)","Width":"45 mm","title":"6AG1010-1AU00-4AA0","Height":"111 mm","at 24 V":"2 A","at 60 V":"0.55 A","at 120 V":"6 A","at 125 V":"0.25 A","at 230 V":"3 A","1 Maximum":"2 000 m","2 Maximum":"3 000 m","3 Maximum":"4 000 m; max. +40 °C (no protective separation)","at 50 °C":"6 A","at 60 °C":"5 A","Web Server":"No","Rated Value":"110 ... 240 V","description":"SIPLUS SIMOCODE pro V basic unit 2 based on 3UF7010-1AU00-0 with conformal coating, -25…+60 °C, PROFIBUS DP interface 12 Mbps, RS-485; 4 I/3 O freely parameterizable US: 110-240 V AC/DC; input for thermistor connection; monostable relay outputs; expandable by expansion modules","Control Unit":"Yes","Direct Start":"Yes","Relay Output":"Yes","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","Digital Input":"Yes","Initial Value":"0.85","Shared Device":"No","Slide Control":"Yes","Test Function":"Yes","Valve Control":"Yes","During Storage":"-40 ... +80 °C","I&M3 - comment":"Yes","lifecycle_stage":"current","During Operation":"-25 ... +60 °C","During Transport":"-40 ... +80 °C","Fastening Method":"screw and snap-on mounting","Full-Scale Value":"1.1","Number Of Inputs":"4","Reverse Starting":"Yes","Bus Communication":"Yes","Current Detection":"Yes","Dahlander circuit":"Yes","Mounting Position":"any","Number Of Outputs":"3","Voltage Detection":"Yes","analog I/O module":"Yes","at DC rated value":"110 ... 240 V","Product Brand Name":"SIPLUS","Star-Delta Circuit":"Yes","Switching Behavior":"monostable","Asymmetry Detection":"Yes","Overload Protection":"Yes","Password Protection":"Yes","Product Designation":"Motor management system","protection class IP":"IP20","Diagnostics Function":"Yes","Maintenance Function":"Yes","Vibration Resistance":"1-6 Hz / 15 mm; 6-500 Hz / 2 g","at 50 Hz rated value":"110 ... 240 V","at 60 Hz rated value":"110 ... 240 V","for AWG cables solid":"1x (20 ... 12), 2x (20 ... 14)","Design Of The Product":"basic unit 2","Overvoltage Detection":"Yes","Transfer Rate Maximum":"12 Mbit/s","according to PROFIBUS":"1","Ground Fault Detection":"Yes","Parameterizable Inputs":"Yes","Undervoltage Detection":"Yes","Active Power Monitoring":"Yes","Circuit Breaker Control":"Yes","Parameterizable Outputs":"Yes","Phase Failure Detection":"Yes","Power Factor Monitoring":"Yes","for AWG cables stranded":"1x (20 ... 14), 2x (20 ... 16)","Current Measuring Module":"Yes","I&M2 - installation date":"Yes","type 1 acc. to IEC 61131":"Yes","Control Unit With Display":"Yes","Data Acquisition Function":"Yes","For Thermistor Connection":"1","With Condensation Maximum":"100 %; RH incl. condensation/frost (no commissioning in bedewed state)","protocol is supported NTP":"No","Phase Sequence Recognition":"Yes","protocol is supported LLDP":"No","protocol is supported SNMP":"No","Blocking Current Evaluation":"Yes","Dahlander reversing circuit":"Yes","according to IEC 60068-2-27":"15g / 11 ms","protocol is supported HTTPS":"No","Pole-Changing Switch Circuit":"Yes","Star-Delta Reversing Circuit":"Yes","Type Of Input Characteristic":"Type 1 in accordance with EN 61131-2","fail-safe digital I/O module":"Yes","Overcurrent Detection 1 Phase":"Yes","Substance Prohibitance (Date)":"05/01/2012","Temperature Monitoring Module":"Yes","supports PROFIenergy shutdown":"No","Ground-Fault Monitoring Module":"Yes","Parameterizable Overload Relay":"Yes","Undercurrent Detection 1 Phase":"Yes","Input For Thermistor Connection":"Yes","Number Of Semiconductor Outputs":"0","Release Value Of Thermoresistor":"1 500 ... 1 650 Ω","Current/Voltage Measuring Module":"Yes","Input For Ground Fault Detection":"No","Response Value Of Thermoresistor":"3 400 ... 3 800 Ω","protocol is supported Modbus RTU":"No","protocol is supported EtherNet/IP":"No","I&M0 - device-specific information":"Yes","protocol is supported OPC UA Server":"No","Input For Analog Temperature Sensors":"No","Surge Voltage Resistance Rated Value":"4 000 V","supports PROFIenergy measured values":"No","EMC immunity according to IEC 60947-1":"corresponds to degree of severity 3","Product Function Soft Starter Control":"Yes","at the Ethernet interface Autosensing":"No","Pole-Changing Switch Reversing Circuit":"Yes","Wire Length For Digital Signals Maximum":"300 m","at the Ethernet interface Autocrossover":"No","due to burst according to IEC 61000-4-4":"2 kV (power ports) / 1 kV (signal ports)","reference code according to IEC 81346-2":"F","Finely Stranded With Core End Processing":"1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)","Monitoring Of Number Of Start Operations":"Yes","protocol is supported PROFIsafe protocol":"Yes","Evaluation Of Thermistor Motor Protection":"Yes","Touch Protection Against Electrical Shock":"finger-safe","at the Ethernet interface Autonegotiation":"No","control supply voltage 1 at DC rated value":"240 V","protocol is supported PROFIBUS DP protocol":"Yes","protocol is supported PROFINET IO protocol":"No","Tightening Torque With Screw-Type Terminals":"0.8 ... 1.2 N·m","Buffering Time In The Event Of Power Failure":"0 s","is supported PROFINET system redundancy (S2)":"No","Design Of Short-Circuit Protection Per Output":"Fuse links: gG 6 A, quick-response 10 A (IEC 60947-5-1), miniature circuit-breaker C char.: 1.6 A (IEC 60947-5-1) or 6 A (I_K < 500 A)","Type Of Voltage Of The Control Supply Voltage":"AC/DC","With Conductor Cross-Section = 0.5 Mm2 Maximum":"50 m","With Conductor Cross-Section = 1.5 Mm2 Maximum":"150 m","With Conductor Cross-Section = 2.5 Mm2 Maximum":"250 m","Electrical Endurance (Operating Cycles) Typical":"100 000","input voltage at digital input at DC rated value":"24 V","EMC emitted interference according to IEC 60947-1":"class A","Mechanical Service Life (Operating Cycles) Typical":"10 000 000","electrostatic discharge according to IEC 61000-4-2":"6 kV contact discharge / 8 kV air discharge","I&M1 - higher level designation/location designation":"Yes","contact rating of auxiliary contacts according to UL":"B300 / R300","Tightening Torque [Lbf·In] With Screw-Type Terminals":"7 ... 10.3 lbf·in","product function is supported Device Level Ring (DLR)":"No","protocol is supported Media Redundancy Protocol (MRP)":"No","Number Of Outputs As Contact-Affected Switching Element":"3","protocol is supported Address Resolution Protocol (ARP)":"No","conducted HF interference emissions according to CISPR11":"corresponds to degree of severity A","field-bound HF interference emission according to CISPR11":"corresponds to degree of severity A","Number Of Digital Inputs With A Common Reference Potential":"4","Type Of Electrical Connection Of The Communication Interface":"9-pin SUB-D socket (12 Mbit) / screw terminal (1.5 Mbit)","type of connectable conductor cross-sections for PROFIBUS wire":"2x 0.34 mm², AWG 22","insulation voltage with degree of pollution 3 at AC rated value":"300 V","Product Component Removable Terminal For Auxiliary And Control Circuit":"Yes","Ambient Condition Relating To Ambient Temperature - Air Pressure - Installation Altitude":"-25 ... +60°C at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // -25 ... +50°C at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // -25 ... +40°C at 658 hPa ... 540 hPa (+3500 m ... +5000 m)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,336.36","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/935f9567c2de656cae20293967c5d8db.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=314955&mlfb=6AG1010-1AU00-4AA0"},"ai":{"faq":[{"question":"Does 6AG1010-1AU00-4AA0 have a web server?","answer":"No, the web server function is not available on this module."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1010-1AU00-4AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1010-1AU00-4AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}