{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1052-2MD00-7BA8","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1052-2MD00-7BA8","canonicalUrl":"https://aoctrl.com/siemens/6AG1052-2MD00-7BA8","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1052-2MD00-7BA8","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS LOGO! 12/24RCEO logic module, 12/24 V DC supply, 8 digital inputs (4 analog-capable), 4 relay outputs, Ethernet with web server, -40 to +70 °C, conformal coated.","salesMarkdown":"## What the -40 to +70 °C range means for deployment The 6AG1052-2MD00-7BA8 operates from -40 to +70 °C with conformal coating. The conformal coating protects against condensation, coolant mist, and oil droplets in the air — a common requirement in machine-tool and packaging-line environments where the standard module would fail from creepage tracking. ## I/O count and analog capability The module provides 8 digital inputs, of which 4 can be configured in analog mode (0 to 10 V). This means a single unit can handle four 0-10 V sensors (pressure transducers, potentiometers, level sensors) without an additional analog expansion module — saving a DIN-rail slot and the cost of a separate I/O block. The 4 relay outputs are rated 10 A resistive and 3 A inductive per channel. The inductive rating matters for driving small contactors, solenoid valves, or motor starters directly; the resistive rating covers heater contactors and indicator loads. Note that short-circuit protection is external — each output circuit needs its own fuse or breaker. ## Ethernet, web server, and data logging built in The 6AG1052-2MD00-7BA8 includes an integrated Ethernet port with a web server and data-logging function. That means you can monitor the module's I/O states, change parameters, and retrieve logged data through a standard browser without a programming cable or dedicated HMI — useful for remote cabinets or commissioning checks. The logic module is programmable with LOGO! Soft Comfort V8 or higher, and older projects are executable. The 400-block memory handles small machine sequences. ## DIN-rail footprint and power supply The 90 mm height and 58 mm depth fit standard 120 mm deep enclosures. The 12/24 V DC supply range (10.8 to 28.8 V DC) means it runs on the same 24 V DC bus as sensors and actuators — no separate power rail needed. A 480-hour power reserve keeps the real-time clock and retentive data alive during a mains outage — enough to bridge a weekend shutdown without battery replacement. No stock-holding claim; each order is sourced per the BOM quantity.","metaTitle":"Siemens 6AG1052-2MD00-7BA8 SIPLUS LOGO!, -40 to 70°C","metaDescription":"Siemens SIPLUS LOGO! 12/24RCEO logic module. 8 DI (4 AI), 4 relay DO, Ethernet, web server. -40 to +70°C, conformal coated. Active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Max.":"70 °C","Min.":"-40 °C","Depth":"58 mm","Width":"71.5 mm","title":"6AG1052-2MD00-7BA8","Height":"90 mm","Number":"190","12 V DC":"Yes","24 V DC":"Yes","CE mark":"Yes","Mounting":"on 35 mm DIN rail, 4 spacing units wide","description":"SIPLUS LOGO! 12/24RCEO -40...+70°C start up -25°C with conformal coating based on 6ED1052-2md00-0BA8. logic module PS/I/O: 12/DC 24V/relay 8 DI (4AI)/4 DO, without display, Memory 400 blocks, modular expandable, Ethernet integr. web server, data log, standard microSD card for LOGO! SOFT Comfort V8 or higher older projects executable","Power reserve":"480 h","Marine approval":"No","lifecycle_stage":"current","At cold restart, min.":"0 °C","according to VDE 0631":"Yes","Number of digital inputs":"8; Of which 4 can be used in analog mode (0 to 10 V)","Short-circuit protection":"No; external fusing necessary","Number of digital outputs":"4; Relays","With Inductive Load, Max.":"3 A","With Resistive Load, Max.":"10 A","permissible range, lower limit (DC)":"10.8 V","permissible range, upper limit (DC)":"28.8 V","developed in accordance with IEC 61131":"Yes","Installation altitude above sea level, max.":"5 000 m","Limit class B, for use in residential areas":"Yes","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","for signal \"1\" permissible range for 0 to 55 °C, max.":"10 A","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2eee7cfcfcdcb38b0735033ecfb3ad0f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=603562&mlfb=6AG1052-2MD00-7BA8"},"ai":{"faq":[{"question":"Does 6AG1052-2MD00-7BA8 have Ethernet and web server?","answer":"Yes, the module includes an integrated Ethernet port with a web server and data-logging function. It can be monitored and configured through a standard browser without additional software or HMI hardware."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1052-2MD00-7BA8","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1052-2MD00-7BA8 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}