{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1124-0QC02-4AX0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1124-0QC02-4AX0","canonicalUrl":"https://aoctrl.com/siemens/6AG1124-0QC02-4AX0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1124-0QC02-4AX0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC HMI, 6AG1124-0QC02-4AX0, features S7-1200/1500 connectivity, PROFINET IRT, MODBUS TCP/IP, MPI, USB, aluminum enclosure, -20 to 60 °C.","salesMarkdown":"The 6AG1124-0QC02-4AX0: The aluminum housing and -20 to 60 °C ambient range allow installation in unheated cabinets or near equipment that raises enclosure temperature, without the derating common to plastic bezel HMIs. ## Communication and Connectivity PROFINET IRT is supported as of WinCC V12; earlier engineering systems revert to RT. For fieldbuses, the panel includes MPI, TCP/IP, MODBUS, and PROFINET RT/IRT. Additional Siemens protocols—DCP, MRP, RDB, CSS, CSV, XML—are built in, eliminating external gateways for line diagnostics and configuration. No CAN interface is present. A USB port is on board for data export, log transfer, or firmware updates. SNMP and LLDP enable network management. Ethernet-based protocols include HTML, HTTP, HTTPS, and DHCP client. ## Software and Runtime Compatibility Engineered in TIA Portal with WinCC Comfort/Advanced, the panel runs WinAC and LOGO! Soft Comfort, supports ActiveX controls and HTML pages, and includes alarms, arrays, icons, and printer output. No Java VM or buzzer. Operator interaction includes hardware buttons, touch sliders, and a speaker for audio feedback. Flash storage retains recipes and logs.","metaTitle":"Siemens 6AG1124-0QC02-4AX0 HMI, -20 to 60°C","metaDescription":"Siemens SIMATIC HMI 6AG1124-0QC02-4AX0. Supports S7-1200/1500, PROFINET IRT, MODBUS, MPI, TCP/IP, USB. Aluminum housing, -20 to 60°C. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["HMI Operator Interfaces"],"specifications":{"CAN":"No","CSS":"Yes","CSV":"Yes","DCP":"Yes","IRT":"Yes; As of WinCC V12","MPI":"Yes","MRP":"Yes","RAM":"Yes","RDB":"Yes","TXT":"Yes","USB":"Yes","XML":"Yes","DHCP":"Yes","HTML":"Yes","HTTP":"Yes","LLDP":"Yes","Max.":"60 °C","Min.":"-20 °C","SNMP":"Yes","Flash":"Yes","HTTPS":"Yes","Icons":"Yes","LOGO!":"Yes","WinAC":"Yes","title":"6AG1124-0QC02-4AX0","Alarms":"Yes","Arrays":"Yes","Buzzer":"No","MODBUS":"Yes","S7-200":"Yes","TCP/IP":"Yes","Buttons":"Yes","Java VM":"No","Plastic":"No","Printer":"Yes","S7-1200":"Yes","S7-1500":"Yes","Sliders":"Yes","Speaker":"Yes","Active X":"Yes","Aluminum":"Yes","Ethernet":"Yes","Hardcopy":"Yes","Info LED":"No","PROFIBUS":"Yes","PROFINET":"Yes","SIMOTION":"No; With WinCC, subsequent version","Switches":"Yes","Error LED":"No","IP (rear)":"IP20","Libraries":"Yes","Power LED":"No","Retentive":"Yes; Back-up duration typically 6 weeks","SINUMERIK":"Yes; with SINUMERIK option package","User view":"Yes","Alarm view":"Yes","Bar graphs":"Yes","I/O fields":"Yes","JavaScript":"Yes","PDF Viewer":"Yes","S7-300/400":"Yes","Simulation":"Yes","Structures":"Yes","Trend view":"Yes","US English":"Yes","USB Mini B":"1; 5-pole","USB memory":"Yes","Windows CE":"Yes","EtherNet/IP":"Yes","Memory card":"Yes","Pocket Word":"Yes","Proprietary":"No","Recipe view":"Yes","System keys":"No","Text fields":"Yes","Web browser":"Yes","description":"***spare part*** SIPLUS HMI TP1500 Comfort based on 6AV2124-0QC02-0AX0 with conformal coating, 0...+50 °C,","Limit values":"Yes","Media Player":"Yes","Multiplexing":"Yes","Pocket Excel":"Yes","Display width":"331.2 mm","Keys with LED":"No","OPC UA Client":"Yes","OPC UA Server":"Yes","Overall depth":"75 mm","SIMATIC Logon":"Yes","Display height":"207 mm","Network camera":"Yes","Processor type":"X86","Software clock":"No","Status/control":"Yes","Synchronizable":"Yes","F(X) Trend View":"Yes","Graphic display":"Yes","MPI/PROFIBUS DP":"Yes","Message archive":"Yes","Mitsubishi (FX)":"Yes","Number of users":"50","Screen diagonal":"15.4 in","Stainless steel":"No","Task-Controlled":"Yes","Time-Controlled":"Yes","lifecycle_stage":"current","Date/time fields":"Yes","Modicon (Modbus)":"Yes","Number of colors":"16 777 216","Numeric keyboard":"Yes","OMRON (FINS TCP)":"No","Rated value (DC)":"24 V","Sm@rtClient view":"Yes","Design of display":"TFT","Device switchover":"Yes","Geometric objects":"Yes","IP (at the front)":"IP65","Message indicator":"Yes","Mounting position":"vertical","Number of recipes":"500","Recipe management":"Yes","Backlight dimmable":"Yes; 0-100 %","Report (shift log)":"Yes","Sequential archive":"Yes","Short-term archive":"Yes","Allen Bradley (DF1)":"Yes","Pointer instruments":"Yes","SIMATIC WinCC Audit":"Yes","System messages HMI":"Yes","Analog/digital clock":"Yes","Acknowledgment groups":"Yes","Alphanumeric Keyboard":"Yes","Languages per project":"32","Number of user groups":"50","Number of user rights":"32","Process value archive":"Yes","Suited for indoor use":"Yes","Design as touch screen":"Yes","Mitsubishi (MC TCP/IP)":"Yes","Mounting cutout, width":"396 mm","Number of bit messages":"6 000","OMRON (LINK/Multilink)":"Yes","Password export/import":"Yes","Suited for outdoor use":"No","Type of supply voltage":"DC","WinCC flexible Compact":"No","Backup/Restore manually":"Yes","Data records per recipe":"1 000","Entries per data record":"2 000","Height of housing front":"310 mm","Modicon (Modbus TCP/IP)":"Yes","Mounting cutout, height":"291 mm","Number of SD card slots":"2","Number of alarm classes":"32","Number of function keys":"0","System diagnostics view":"Yes","WinCC flexible Advanced":"No","WinCC flexible Standard":"No","Active power input, typ.":"36 W","Electronic print to file":"Yes; PDF, HTML","Number of USB interfaces":"2; USB 2.0","Permanent window/default":"Yes","Recipe memory expandable":"Yes","WinCC Basic (TIA Portal)":"No","With software interfaces":"No","Number of analog messages":"200","S7 alarm number procedure":"Yes","SIMATIC WinCC Sm@rtServer":"Yes","STEP 7 Basic (TIA Portal)":"No","Hardware clock (real-time)":"Yes","Number of other interfaces":"0","Weight (without packaging)":"5.2 kg","Width of the housing front":"415 mm","WinCC Comfort (TIA Portal)":"Yes; V11 SP2 or higher","Allen Bradley (EtherNet/IP)":"Yes","At maximum tilt angle, max.":"40 °C; = Tmax","At maximum tilt angle, min.":"0 °C; = Tmin","Number of RS 232 interfaces":"0","Number of RS 422 interfaces":"1","Number of RS 485 interfaces":"1; RS 422 / 485 combined","Starting current inrush I2t":"0.5 A²·s","WinCC Advanced (TIA Portal)":"Yes; V11 SP2 or higher","Backup/Restore automatically":"Yes","Enclosure Type 4 at the front":"Yes","MTBF backlighting (at 25 °C)":"80 000 h","Number of archives per device":"50","Number of configurable images":"750","Number of entries per archive":"50 000","Number of parallel interfaces":"0","Using External Storage Medium":"No","Wall mounting/direct mounting":"No","Enclosure Type 4x at the front":"Yes","Industrial Ethernet status LED":"3","Memory available for user data":"24 Mbyte","Number of Visual Basic Scripts":"Yes","Number of variables per device":"4 096","Number of variables per screen":"400","Process value display (output)":"Yes","Size of internal recipe memory":"4 Mbyte","For vertical installation, max.":"40 °C; = Tmax","For vertical installation, min.":"0 °C; = Tmin","Number of entries per text list":"500","Symbolic I/O fields (text list)":"Yes","WinCC Professional (TIA Portal)":"Yes; V11 SP2 or higher","Number of 20 mA interfaces (TTY)":"0","Number of characters per message":"80","Number of text lists per project":"500","STEP 7 Professional (TIA Portal)":"No","Current consumption (rated value)":"1.5 A","Number of function keys with LEDs":"0","Supports protocol for PROFINET IO":"Yes","Graphic I/O fields (graphics list)":"Yes","Number of online/runtime languages":"32","Number of entries per graphics list":"500","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Mounting in portrait format possible":"Yes","Number of complex objects per screen":"40","Number of graphics lists per project":"500","Number of process values per message":"8","Mounting in landscape format possible":"Yes","Process value default (input) possible":"Yes","Number of industrial Ethernet interfaces":"3","Number of ports of the integrated switch":"2","Limit class A, for use in industrial areas":"Yes","Direct keys (touch buttons as S7 input I/O)":"40","Installation altitude above sea level, max.":"5 000 m","Limit class B, for use in residential areas":"No","SIMATIC HMI MM memory card: Multi Media Card":"Yes","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Alarm system (incl. buffer and acknowledgment)":"Yes","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","SIMATIC HMI SD memory card: Secure Digital memory card":"Yes","System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... )":"Yes","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Maximum Permissible Angle Of Inclination Without External Ventilation":"35°","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$5,002.00 – $7,573.52","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/89e4a52718c564616ec3859ccbe89b58.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=295052&mlfb=6AG1124-0QC02-4AX0"},"ai":{"faq":[{"question":"What communication protocols does the 6AG1124-0QC02-4AX0 support?","answer":"PROFINET IRT (as of WinCC V12), MPI, MODBUS, TCP/IP, HTTP, HTTPS, SNMP, LLDP, DHCP, DCP, MRP, RDB, CSS, CSV, and XML. CAN is not supported."},{"question":"What ambient temperature range does the HMI handle?","answer":"-20 to 60 °C."},{"question":"Does it have a USB port?","answer":"Yes, a USB port is provided."},{"question":"Does the panel include a speaker or buzzer?","answer":"It has a speaker for audio feedback, but no buzzer."},{"question":"What Siemens PLCs can connect directly?","answer":"S7-1200, S7-1500, and S7-200 via MPI or PROFINET."},{"question":"Does the 6AG1124-0QC02-4AX0 have a metal enclosure?","answer":"Yes, it uses an aluminum housing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1124-0QC02-4AX0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1124-0QC02-4AX0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}