{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1132-4HB13-2AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1132-4HB13-2AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1132-4HB13-2AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1132-4HB13-2AB0","rawCanonicalId":null},"summary":{"shortDescription":"SIPLUS ET 200S EM 2DQ RLY 5A, 6AG1132-4HB13-2AB0, 2 relay outputs 5 A, conformally coated for -40 to +60 °C, 15 mm wide.","salesMarkdown":"This 6AG1132-4HB13-2AB0 is a SIPLUS ET 200S electronic module carrying two relay outputs, each rated 5 A for signal '1' and 5 A thermal continuous current. It is the conformally coated, extended-temperature variant (−40 to +60 °C) of the standard 6ES7132-4HB13-0AB0. Dimensions are 15 mm wide × 81 mm high × 52 mm deep, mounting as a standard ET 200S electronic module. Reverse polarity protection is built in on the backplane side, but the relay outputs themselves lack short-circuit protection — an external fuse or breaker per channel is required for the load circuit. No diagnostic function is present; status indication is a green LED per output. On CPU/master STOP the module can substitute a value (0 or 1, configurable) or keep the last state, which matters for fail-safe system design. Galvanic isolation exists between channels and backplane bus as well as between channels and load voltage L+, enabling mixed-load wiring in the same assembly.","metaTitle":"Siemens 6AG1132-4HB13-2AB0 SIPLUS 2DO Relay, 5A, -40/+60°C","metaDescription":"Active production. SIPLUS ET 200S EM 2DQ RLY 5A with conformal coating, -40 to +60°C. 2 relay outputs, 5A thermal continuous. 15mm width. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Max.":"60 °C; = Tmax","Min.":"-40 °C; = Tmin","Depth":"52 mm","Width":"15 mm","title":"6AG1132-4HB13-2AB0","Height":"81 mm","description":"SIPLUS ET 200S EM 2DQ RLY 5 A based on 6ES7132-4HB13-0AB0 with conformal coating, -40…+60 °C, 24 V-48 V DC/5 A, 24 V-230 V AC/5 A 15 mm width,substitute value output 5 units per packing unit","With Packing":"2 bit","Shielded, Max.":"1 000 m","Weight, approx.":"50 g","lifecycle_stage":"current","Power loss, typ.":"0.6 W","Rated value (DC)":"24 V; From power module","Unshielded, Max.":"600 m","On Lamp Load, Max.":"2 Hz","Between The Channels":"Yes","Diagnostics function":"No","Type of digital output":"Relays","Short-circuit protection":"No","Number of digital outputs":"2","With Inductive Load, Max.":"0.5 Hz","With Resistive Load, Max.":"2 Hz","For Signal \"1\" Rated Value":"5 A","Controlling a digital input":"Yes","Response to CPU/master STOP":"Substitute a value/keep last value","Reverse polarity protection":"Yes","Substitute values connectable":"Yes; 0/1","Address space per module, max.":"1 byte","Thermal continuous current, max.":"5 A","from backplane bus 3.3 V DC, max.":"10 mA","For Signal \"1\" Minimum Load Current":"8 mA","Between The Channels And Backplane Bus":"Yes","Status indicator digital output (green)":"Yes","Between the channels and load voltage L+":"Yes","from load voltage L+ (without load), max.":"30 mA","Installation altitude above sea level, max.":"2 000 m","Limitation of inductive shutdown voltage to":"No","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e51396e92b3a763c69906944371f4bb2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1480759&mlfb=6AG1132-4HB13-2AB0"},"ai":{"faq":[{"question":"What is the operating temperature range of this module?","answer":"The module is rated for −40 to +60 °C ambient (vertical and horizontal mounting same range) with derating above 40 °C for vertical installation."},{"question":"Does this module have short-circuit protection?","answer":"No, short-circuit protection is not provided on the outputs. An external fuse or circuit breaker must be used on each load circuit."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1132-4HB13-2AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1132-4HB13-2AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}