{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1132-6BD20-7BA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1132-6BD20-7BA0","canonicalUrl":"https://aoctrl.com/siemens/6AG1132-6BD20-7BA0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1132-6BD20-7BA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS 6AG1132-6BD20-7BA0 ET 200SP digital output module, 4 x PNP source outputs, rated 2 A, with wire-break and short-circuit diagnostics, extended temperature -40 to 70 °C, horizontal.","salesMarkdown":"## 4-channel PNP output slice for ET 200SP, SIPLUS rated The Siemens 6AG1132-6BD20-7BA0 is a SIPLUS ET 200SP digital output module offering 4 source (PNP) outputs, each rated at 2 A for signal '1'. It fits a 15 mm slice on a BU type A0 BaseUnit, drawing about 1 W from the backplane bus. Key diagnostics include wire-break detection per channel, group error reporting, short-circuit protection with a response threshold of 2.8 to 5.2 A, and supply-voltage monitoring. This makes it suited for maintaining batch traceability in a brewery or distillery where a lost feedback loop from a valve or pump could break a CIP cycle. ## Extended temperature range with condensation tolerance A valuable spec for a brewmaster's grain receival pit or a cold-storage fermentation hall where moisture hangs in the air and standard electronics may fail. ## Current derating above 60 °C — plan your thermal headroom Above 60 °C the number of simultaneously controllable outputs is reduced: either 2 x 0.25 A or 4 x 0.125 A, with a total current cap of 0.5 A. At lower temperatures full 2 A per channel is available, but if the cabinet sees warm surfaces from neighbouring drives, use the derated values for your load calculations. ## Integration note on switching frequencies and cable lengths Maximum resistive load switching frequency is 100 Hz; inductive loads are limited to 2 Hz. For incandescent lamp loads it's 10 Hz. Cable run: shielded up to 1 000 m, unshielded 200 m. Verified 0-to-1 transition within 50 µs, 1-to-0 within 100 µs. Isolation tested at 707 V DC between circuits (75 V DC / 60 V AC between different circuits).","metaTitle":"Siemens SIPLUS 6AG1132-6BD20-7BA0 ET 200SP DQ4, 4 PNP 2A, -4","metaDescription":"SIPLUS ET 200SP digital output module, 4 PNP source outputs, rated 2 A per channel. Wire-break & short-circuit detection. Active production. Temp range -40 to 70 °C, condensation t","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Depth":"58 mm","Width":"15 mm","title":"6AG1132-6BD20-7BA0","Height":"73 mm","Wire-break":"Yes","Group error":"Yes","Lower Limit":"12 Ω","Upper Limit":"3 400 Ω","description":"SIPLUS ET 200SP DQ 4x24VDC/2A Standard based on 6ES7132-6BD20-0BA0 with conformal coating, -40…+70 °C, digital output module, suitable for BU type A0, color code CC02, channel diagnostics,","For Uprating":"No","Short-circuit":"Yes","Shielded, Max.":"1 000 m","Weight, approx.":"30 g","lifecycle_stage":"current","\"0\" To \"1\", Max.":"50 µs","\"1\" To \"0\", Max.":"100 µs","Power loss, typ.":"1 W","Rated value (DC)":"24 V","Unshielded, Max.":"200 m","usable BaseUnits":"BU type A0","On Lamp Load, Max.":"10 Hz","Isolation tested with":"707 V DC","Type of digital output":"Source output (PNP, current-sourcing)","Response threshold, typ.":"2.8 to 5.2 A","Short-circuit protection":"Yes","Number of digital outputs":"4; > +60 °C number of simultaneously controllable outputs max. 2x 0.25 A or max. 4x 0.125 A, max. total current 0.5 A","With Inductive Load, Max.":"2 Hz","With Resistive Load, Max.":"100 Hz","Between Different Circuits":"75 V DC/60 V AC","For Signal \"1\" Rated Value":"2 A","Controlling a digital input":"Yes","Vertical Installation, Max.":"50 °C; = Tmax","Vertical Installation, Min.":"-40 °C; = Tmin","Horizontal Installation, Max.":"70 °C; = Tmax; > +60 °C number of simultaneously controllable outputs max. 2x 0.25 A or max. 4x 0.125 A, max. total current 0.5 A","Horizontal Installation, Min.":"-40 °C; = Tmin (incl. condensation/frost)","Monitoring the supply voltage":"Yes","Suitable for safety functions":"No","Address space per module, max.":"32 byte","For Redundant Control Of A Load":"Yes","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Installation altitude above sea level, max.":"5 000 m","Limitation of inductive shutdown voltage to":"Typ. L+ (-50 V)","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e51396e92b3a763c69906944371f4bb2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=514757&mlfb=6AG1132-6BD20-7BA0"},"ai":{"faq":[{"question":"What is the width and depth of this module?","answer":"Width 15 mm, depth 58 mm, height 73 mm — it occupies a single 15 mm wide slot on the ET 200SP BaseUnit (BU type A0)."},{"question":"What are the key output ratings for this module?","answer":"Four PNP source outputs (sourcing), each rated 2 A at 24 V DC (permissible range 19.2 to 28.8 V DC). Short-circuit protection and wire-break detection are built in. The response threshold for overload is 2.8 to 5.2 A."},{"question":"Does this module support safety functions or redundant control?","answer":"It is not suitable for safety functions, but it does support redundant control of a load, meaning you can parallel two outputs to drive a single valve or solenoid with increased availability."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1132-6BD20-7BA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1132-6BD20-7BA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}