{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1132-6HD00-7BB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1132-6HD00-7BB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1132-6HD00-7BB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1132-6HD00-7BB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 6AG1132-6HD00-7BB0 PLC output module, 4 relay outputs, 20 A per module, 24 V DC, 20 mm width, I&M data 0-3, active production.","salesMarkdown":"## Relay output module for tight DIN-rail slots The Siemens 6AG1132-6HD00-7BB0 is a 4-relay output module that fits a 20 mm wide DIN-rail slot — one of the narrowest footprints for a quad relay bank in the S7-1200 ecosystem. It carries a total module current of 20 A, with per-channel limits that derate with ambient temperature: 20 A up to 40 °C, 16 A at 50 °C, and 16 A at 60 °C. Above 60 °C horizontal, each relay is capped at 3 A continuous and the module total drops to 12 A. ## What the ratings mean for your panel The 20 A total module current is the sum of all relay outputs — if you run all four at 5 A each, you're at the limit. The derating above 60 °C is a hard constraint: at 65 °C horizontal, you can only pull 3 A per relay and 12 A total, so plan your load distribution accordingly. The module requires a BU type B0 base unit (sold separately) and draws 100 mA max from the 24 V DC supply without load. Reverse polarity protection is built in, and the supply voltage is monitored via a green PWR LED. I&M data 0 through 3 is supported, meaning the module reports its identity and maintenance history to the controller — useful for asset tracking in larger lines. ## Lifecycle and sourcing reality Sourced and quoted to order against your BOM quantity; availability and current pricing confirmed at RFQ time.","metaTitle":"Siemens 6AG1132-6HD00-7BB0 4-Relay Output Module, 20 A","metaDescription":"Siemens 6AG1132-6HD00-7BB0 PLC output module with 4 relay outputs, 20 A total per module, 24 V DC supply. Active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Width":"20 mm","title":"6AG1132-6HD00-7BB0","I&M data":"Yes; I&M0 to I&M3","description":"***spare part*** SIPLUS ET 200SP RQ 4x120VDC/230VAC/5A based on 6ES7132-6HD00-0BB0 with conformal coating, -40…+70 °C, start up -25 °C, relay module normally open, suitable for BU type B0, color code CC00, module diagnostics","Shielded, Max.":"1 000 m","Weight, approx.":"40 g","lifecycle_stage":"current","Diagnostic alarm":"Yes","Power loss, typ.":"1.5 W","Rated value (DC)":"24 V","Unshielded, Max.":"200 m","usable BaseUnits":"BU type B0","On Lamp Load, Max.":"2 Hz","up to 40 °C, max.":"20 A","up to 50 °C, max.":"16 A","up to 60 °C, max.":"16 A","Between The Channels":"Yes","Isolation tested with":"2 500 V DC (type test)","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red DIAG LED","Number of relay outputs":"4","Current per module, max.":"20 A","Current consumption, max.":"100 mA; without load","With Inductive Load, Max.":"0.5 Hz","With Resistive Load, Max.":"2 Hz","Reverse polarity protection":"Yes","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"-40 °C; = Tmin; Startup @ -25 °C","Horizontal Installation, Max.":"70 °C; = Tmax; > +60 °C max. continuous current per relay 3 A, max. total current module 12 A","Horizontal Installation, Min.":"-40 °C; = Tmin; Startup @ -25 °C","Monitoring the supply voltage":"Yes","Substitute values connectable":"Yes","Address space per module, max.":"1 byte; + 1 byte for QI information","Thermal continuous current, max.":"5 A","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","External Protection For Relay Outputs":"Yes, with 6A","Between The Channels And Backplane Bus":"Yes","Between Backplane Bus And Supply Voltage":"500 V DC","Monitoring of the supply voltage (PWR-LED)":"Yes; green PWR LED","Rated supply voltage of relay coil L+ (DC)":"24 V","Between Channels And Backplane Bus/Supply Voltage":"2 500 V DC","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m)","Color code for module-specific color identification plate":"CC00","Between The Channels And The Power Supply Of The Electronics":"Yes","Current consumption of relays (coil current of all relays), max.":"40 mA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e51396e92b3a763c69906944371f4bb2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=42957&mlfb=6AG1132-6HD00-7BB0"},"ai":{"faq":[{"question":"What base unit does 6AG1132-6HD00-7BB0 require?","answer":"It requires a BU type B0 base unit. The base unit is ordered separately and provides the backplane connection and DIN-rail mounting."},{"question":"What is the maximum current per relay at high ambient temperatures?","answer":"Up to 60 °C horizontal, each relay can carry 5 A continuous (16 A total module). Above 60 °C up to 70 °C, each relay is limited to 3 A and the module total to 12 A."},{"question":"Does 6AG1132-6HD00-7BB0 support I&M data?","answer":"Yes, it supports I&M data 0 through 3, enabling identification and maintenance data exchange with the controller."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1132-6HD00-7BB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1132-6HD00-7BB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}