{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1132-6HD01-7BB1","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1132-6HD01-7BB1","canonicalUrl":"https://aoctrl.com/siemens/6AG1132-6HD01-7BB1","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1132-6HD01-7BB1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 6AG1132-6HD01-7BB1 digital output module, 8 relay outputs, 20 A at 40 °C, 230 V AC / 24 V DC, 20 mm wide, for SIMATIC S7-1200.","salesMarkdown":"## Panel fit and output capacity The 6AG1132-6HD01-7BB1: This is an 8-channel relay output module for the SIMATIC S7-1200 system — 20 mm wide, 73 mm tall, 58 mm deep. It snaps onto the standard DIN rail in the same footprint as the CPU and other signal modules, so it shares the backplane bus without extra wiring for the I/O data. Each relay output is rated 20 A continuous up to 40 °C, derating to 16 A at 50 °C and 60 °C. That current capacity is unusual for a compact S7-1200 module — it directly drives small motors, contactor coils, or valve solenoids without an interposing relay. The outputs accept both AC (230 V rated) and DC (24 V rated) loads, with channel-to-channel isolation and a tested isolation voltage of 2,500 V DC. This means mixed-voltage wiring in the same module is safe — one channel can switch a 24 V DC pilot light while another switches a 230 V AC contactor. ## Sourcing and lifecycle for the BOM line It uses the type B0 or base unit (BU) for the S7-1200 system, which is the same mechanical interface as the standard 6ES7132-6HD01-0BB0. The 6AG1 prefix indicates the SIPLUS variant, rated for extended temperature range and harsh environments — confirm the base unit part number separately if you are replacing a standard module. ## Diagnostics and wiring notes The module provides a diagnostic alarm and a green/red DIAG LED for module-level fault indication, plus a green LED per channel for status. That is enough to isolate a failed output without a handheld meter — the DIAG LED flashes on a short-circuit or wire-break condition. Power dissipation is 1.5 W typical — negligible for cabinet thermal budgeting, but worth noting if the module sits in a sealed enclosure with other high-current relay modules. The unshielded cable run is limited to 200 m; shielded cable extends that to 1,000 m.","metaTitle":"Siemens 6AG1132-6HD01-7BB1 Digital Output Module, 20 A Relay","metaDescription":"Siemens 6AG1132-6HD01-7BB1 digital output module, 8 relay outputs, rated 20 A at 40 °C, 230 V AC / 24 V DC. Active production, sourced per RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"DQ":"Yes","MSO":"No","PWM":"No","Depth":"58 mm","Width":"20 mm","title":"6AG1132-6HD01-7BB1","Height":"73 mm","Inputs":"+ 1 byte for QI information","Outputs":"1 byte","I&M data":"Yes; I&M0 to I&M3","Wire-break":"No","description":"SIPLUS ET 200SP RQ 4x 120V DC..230VAC/5A ST based on 6ES7132-6HD01-0BB1 with conformal coating, -40…+70 °C, relay module normally open, suitable for BU type B0 or B1, module diagnostics","For Uprating":"No","Oversampling":"No","Short-circuit":"No","Shielded, Max.":"1 000 m","Current-sinking":"Yes","For Logic Links":"Yes","Weight, approx.":"40 g","lifecycle_stage":"current","Current-sourcing":"Yes","Diagnostic alarm":"Yes","Isochronous mode":"No","Power loss, typ.":"1.5 W","Rated value (AC)":"230 V","Rated value (DC)":"24 V","Unshielded, Max.":"200 m","usable BaseUnits":"BU type B0, B1","Automatic encoding":"Yes","FW update possible":"No","On Lamp Load, Max.":"2 Hz","up to 40 °C, max.":"20 A","up to 50 °C, max.":"16 A; in all other mounting positions","up to 60 °C, max.":"16 A","Between The Channels":"Yes","Diagnostics function":"Yes","Isolation tested with":"2 500 V DC (type test)","Redundancy capability":"Yes","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red DIAG LED","Type of digital output":"Relays","For Channel Diagnostics":"No","Number of relay outputs":"4","Switching current, min.":"100 mA; 5 V DC","Current per module, max.":"20 A","Short-circuit protection":"No","Current per channel, max.":"5 A","Mechanical coding element":"Yes","Number of digital outputs":"4","With Inductive Load, Max.":"2 A; see additional description in the manual","With Resistive Load, Max.":"5 A; see additional description in the manual","Reverse polarity protection":"Yes","Vertical Installation, Max.":"50 °C; in all other mounting positions","Vertical Installation, Min.":"-40 °C; in all other mounting positions","Rated switching voltage (AC)":"24V AC to 230V AC","Rated switching voltage (DC)":"24 V DC to 120 V DC","Horizontal Installation, Max.":"70 °C; = Tmax; see Derating BasedOn (e.g. manual), additionally Tmax > 60 °C max. continuous current of 3 A per relay","Horizontal Installation, Min.":"-40 °C; = Tmin (incl. condensation/frost)","Monitoring the supply voltage":"Yes","Substitute values connectable":"Yes","Suitable for safety functions":"No","DQ with energy-saving function":"No","For Redundant Control Of A Load":"Yes","Digital outputs, parameterizable":"Yes","Number of operating cycles, max.":"7 000 000; see additional description in the manual","Thermal continuous current, max.":"5 A; Max. 1 385 VA, 150 W","Current consumption (rated value)":"55 mA; without load","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","External Protection For Relay Outputs":"Yes, with 6A","Between The Channels And Backplane Bus":"Yes","Between Backplane Bus And Supply Voltage":"707 V DC (type test)","Monitoring of the supply voltage (PWR-LED)":"Yes; green PWR LED","Rated supply voltage of relay coil L+ (DC)":"24 V","Installation altitude above sea level, max.":"3 000 m","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Between Channels And Backplane Bus/Supply Voltage":"2 500 V DC","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 1 K/100 m) at 795 hPa ... 701 hPa (+2 000 m ... +3 000 m)","Color code for module-specific color identification plate":"CC40","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Between The Channels And The Power Supply Of The Electronics":"Yes","Current consumption of relays (coil current of all relays), max.":"40 mA","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$250.58","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e51396e92b3a763c69906944371f4bb2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1116058&mlfb=6AG1132-6HD01-7BB1"},"ai":{"faq":[{"question":"What is the maximum current per channel on this relay output module?","answer":"Each relay output is rated 20 A at 40 °C, derating to 16 A at 50 °C and 60 °C. The rating applies to all mounting positions at 50 °C and above."},{"question":"What base unit does 6AG1132-6HD01-7BB1 require?","answer":"It uses the type B0 or base unit (BU) from the S7-1200 system. The base unit is ordered separately and provides the terminal connections for field wiring."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1132-6HD01-7BB1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1132-6HD01-7BB1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}