{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1134-4GB11-2AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1134-4GB11-2AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1134-4GB11-2AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1134-4GB11-2AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS 6AG1134-4GB11-2AB0, 2-channel analog input module, 4-20 mA / ±20 mA, 24 V DC, 60 °C, -25 °C, 0.6 W.","salesMarkdown":"## Siemens SIPLUS 6AG1134-4GB11-2AB0 – 2-Channel Analog Input Module This SIPLUS module gives you two analog inputs, configurable for 4 to 20 mA (with 50 Ω burden) or ±20 mA ranges. Rated for 24 V DC from the S7-1200 backplane, pulling just 0.6 W typical. It works across -25 °C to 60 °C ambient, so it fits in unheated cabinets or plant-floor panels without derating. Dimensions are 15 mm wide, 81 mm high, 52 mm deep – slim enough for high-density layouts. Conversion time per channel is 65 ms (55 / 65 ms variant), and the module supports digital filtering in four stages to smooth noisy process values. Parameterizable via the engineering software. Compliance is covered: CE marked and UL approved, so it clears panel certification for export or UL 508A builds. ## Field Wiring and Diagnostics Shielded cable runs up to 200 m are allowed – that sets the maximum distance from the sensor. Wire-break diagnostics are only available when the input is configured to the 4 to 20 mA range; it won't trigger in ±20 mA mode. Group error (SF red LED) and wire-break, overflow/underflow, and group diagnostics can be enabled or disabled individually. The module does not support isochronous mode. Isolation is tested to 500 V DC between channels and the backplane bus.","metaTitle":"Siemens 6AG1134-4GB11-2AB0 Analog Input, 60°C","metaDescription":"Active production. 2 analog inputs, 4-20 mA/±20 mA, 24 V DC. SIPLUS S7-1200 module. -25 to 60°C. Sourced to order. UL, CE. Confirm BOM fit now.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Max.":"60 °C; = Tmax","Min.":"-25 °C; = Tmin","Depth":"52 mm","Width":"15 mm","title":"6AG1134-4GB11-2AB0","Height":"81 mm","Remark":"4 byte","CE mark":"Yes","Step: low":"Yes; 4x cycle time","Step: High":"Yes; 64x cycle time","Step: None":"Yes; 1x cycle time","Wire-break":"Yes; Measuring range 4 to 20 mA only","Group error":"Yes","UL approval":"Yes","description":"SIPLUS ET 200S EM 2AI I-4-wire transducer based on 6ES7134-4GB11-0AB0 with conformal coating, -25…+60 °C,","Step: Medium":"Yes; 32x cycle time","4 mA to 20 mA":"Yes; 50 Ohm","Shielded, Max.":"200 m","Parameterizable":"Yes; In four stages by means of digital filtering","Weight, approx.":"40 g","lifecycle_stage":"current","-20 mA to +20 mA":"Yes; 50 Ohm","Isochronous mode":"No","Power loss, typ.":"0.6 W","Rated value (DC)":"24 V; From power module","Group diagnostics":"Disable / enable","Overflow/underflow":"Disable / enable","Between The Channels":"No","Group error SF (red)":"Yes","Integration time (ms)":"16,7 / 20 ms","Isolation tested with":"500 V DC","Measurement principle":"integrating","Diagnostics wire break":"Disable / enable (only in measuring range 4 to 20 mA)","Number of analog inputs":"2","Conversion time (per channel)":"65 ms; 55 / 65 ms","Address space per module, max.":"4 byte","Cycle time (all channels) max.":"Number of active channels per module x basic conversion time","from backplane bus 3.3 V DC, max.":"10 mA","Between The Channels And Backplane Bus":"Yes","Current, relative to input range, (+/-)":"0.4 %","Between the channels and load voltage L+":"No","from load voltage L+ (without load), max.":"30 mA","Installation altitude above sea level, max.":"5 000 m","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resolution with overrange (bit including sign), max.":"14 bit; ±20 mA: 14 bit, 4 to 20 mA: 13 bit","Interference voltage suppression for interference frequency f1 in Hz":"50 / 60 Hz","Permissible Input Current For Current Input (Destruction Limit), Max.":"40 mA","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$227.33","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e51396e92b3a763c69906944371f4bb2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=124978&mlfb=6AG1134-4GB11-2AB0"},"ai":{"faq":[{"question":"What is the operating temperature range?","answer":"The module is rated for -25 °C to 60 °C ambient."},{"question":"What approvals does it carry?","answer":"CE and UL approvals are listed on the module."},{"question":"Can I run shielded cable up to 200 m?","answer":"Yes, shielded cable length is permitted up to 200 m."},{"question":"Does wire-break detection work in the ±20 mA range?","answer":"No, wire-break diagnostics are only available when the input is set to 4 to 20 mA."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1134-4GB11-2AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1134-4GB11-2AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}