{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1134-4GD00-2AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1134-4GD00-2AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1134-4GD00-2AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1134-4GD00-2AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS ET 200SP 6AG1134-4GD00-2AB0 analog input module, 4 AI 4-20 mA, 24 V from power module, -25…70 °C, 7 byte address space.","salesMarkdown":"The Siemens 6AG1134-4GD00-2AB0 is a SIPLUS variant of the ET 200SP analog input module with 4 channels for 4-20 mA signals, rated for extended ambient temperatures from -25 °C to 70 °C, and carrying current lifecycle status for OEM and MRO sourcing. It accepts 4-20 mA into 25 Ohm burden, integrates over programmable time windows (16,67 or 20 ms), and has a max cycle time of 33–40 ms across all channels. The -25 °C to 70 °C range is the SIPLUS differentiator versus the standard ET 200SP AI (0–60 °C). If your panel lives in a refrigerated warehouse, freezer tunnel, or outdoor cabinet in a cold climate, this module avoids derating. The 4-20 mA signal into 25 Ohm means the loop power supply must provide sufficient voltage above the module's burden. Most 2-wire transmitters can handle that, but verify compliance voltage for long cable runs. Short-circuit proof at approx. 200 mA per module: if a field wire shorts to ground, the module limits current and reports the fault via group error SF (red LED). It does not isolate between channels, so a single short can disrupt all four inputs unless your wiring separates the loops. Wire-break detection is active only in the 1–5 V measuring range (remark: yes, but for 4-20 mA the break is implied by going below 4 mA – the module flags that as overflow/underflow, not a separate break alarm). Keep that in mind when configuring the input range in your PLC hardware config. ## Integrator notes: mounting and wiring Shielded cable runs up to 200 m are approved; connect the shield at the module side only (no shield on the field end) to avoid ground loops. The internal filter is integrating, so fast transients couple partly through – use twisted-pair cable in high-EMI environments. Isochronous mode is not supported (= No). If your controller demands deterministic cyclic data with zero jitter, this module is not for that use case. ## Sourcing reality: active, orderable, region-agnostic No functional second-source exists: the listed peer MPNs (6ES7136-6AB00-0CA1, 6AG1212-1AE40-2XB0, 6AG1212-1AE40-4XB0) are not analog input modules but other S7 family products. You cannot drop this into a slot meant for a standard ET 200SP AO or CPU without rewiring and reconfiguration. Compliance: CE marked. Isolation tested at 500 V DC. RoHS/REACH/UL are not explicitly in the listed specs – your compliance team should request the Siemens Certificate of Compliance with the RFQ if needed.","metaTitle":"Siemens 6AG1134-4GD00-2AB0 SIPLUS AI 4xI 4-20mA, -25..70°C","metaDescription":"Active Siemens SIPLUS analog input module, 4 inputs 4-20 mA, 24V, -25 to 70°C, 7 byte address space. Source via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Max.":"70 °C; = Tmax","Min.":"-25 °C; = Tmin","Depth":"52 mm","Width":"15 mm","title":"6AG1134-4GD00-2AB0","Height":"81 mm","Remark":"7 byte","CE mark":"Yes","Step: low":"Yes; 4x cycle time","Step: High":"Yes; 32x cycle time","Step: None":"Yes; 1x cycle time","Wire-break":"Yes; Measuring range 1 to 5 V only","Group error":"Yes","description":"SIPLUS ET 200S EM 4 AI I 2-wire based on 6ES7134-4GD00-0AB0 with conformal coating, -25…+70 °C, electronic module 4-20 mA; 13 bit 15 mm width, for 2-wire transmitter cycle time 40 ms/module with SF LED (group fault)","Step: Medium":"Yes; 16x cycle time","4 mA to 20 mA":"Yes; Into 25 Ohm","Shielded, Max.":"200 m","Parameterizable":"Yes; in 4 stages","Weight, approx.":"40 g","lifecycle_stage":"current","Isochronous mode":"No","Power loss, typ.":"0.6 W","Rated value (DC)":"24 V; From power module","Group diagnostics":"1","Overflow/underflow":"1","Short-Circuit Proof":"Yes; approx. 200 mA for module","Between The Channels":"No","Group error SF (red)":"Yes","Integration time (ms)":"16,67 / 20 ms","Isolation tested with":"500 V DC","Measurement principle":"integrating","Diagnostics wire break":"1","Number of analog inputs":"4","Reverse polarity protection":"Yes","Address space per module, max.":"8 byte","Cycle time (all channels) max.":"40 ms; 33 to 40 ms","Integration time, parameterizable":"Yes","from backplane bus 3.3 V DC, max.":"10 mA","Between The Channels And Backplane Bus":"Yes","Current, relative to input range, (+/-)":"0.3 %","Between the channels and load voltage L+":"No","from load voltage L+ (without load), max.":"125 mA","Installation altitude above sea level, max.":"5 000 m","Product Function / Supply Voltage For Transmitters":"Yes","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resolution with overrange (bit including sign), max.":"13 bit; 4 to 20 mA: 13 bit","Interference voltage suppression for interference frequency f1 in Hz":"50 / 60 Hz","Permissible Input Current For Current Input (Destruction Limit), Max.":"30 mA; limited electronically","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$290.83","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e51396e92b3a763c69906944371f4bb2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=237175&mlfb=6AG1134-4GD00-2AB0"},"ai":{"faq":[{"question":"What compliance documentation does this module carry?","answer":"CE mark is stated. Isolation tested with 500 V DC. RoHS, REACH, and UL are not explicitly listed in the provided specification; we can request the manufacturer's declaration upon RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1134-4GD00-2AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1134-4GD00-2AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}