{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1134-4JB51-7AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1134-4JB51-7AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1134-4JB51-7AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1134-4JB51-7AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 6AG1134-4JB51-7AB0 analog input module, 4 inputs Pt100/Ni100, 24 VDC backplane power, 0.6 W, 15 x 81 x 52 mm.","salesMarkdown":"The Siemens 6AG1134-4JB51-7AB0 is a four-channel analog input module designed for resistance thermometers. It accepts Pt100 and Ni100 sensors in both standard and climatic ranges, and two of the four inputs support 3- or 4-wire connection to cancel lead resistance. Conversion time per channel is 66 or 80 ms depending on the diagnostic wire-break test being active. Cycle time for all active channels equals the number of channels times the basic conversion time, up to a maximum of 8 bytes of address space. Digital filtering is parameterizable in four steps: 1x, 4x, 32x, or 64x cycle time. Integration time is selectable at 16,7 ms or 20 ms, matching 60 Hz or 50 Hz line frequencies. Diagnostics cover wire-break, overflow/underflow, and group error (SF red). Each diagnostic group can be disabled or enabled individually. The module carries CE marking. Isolation is tested at 500 V DC. Reverse polarity protection is built in. Maximum shielded cable length is 200 m.","metaTitle":"Siemens 6AG1134-4JB51-7AB0 Analog Input, 4 ch, Pt100/Ni100,","metaDescription":"Siemens 6AG1134-4JB51-7AB0 analog input module, 4 RTD channels, temperature range -25 to 70 °C, 0.6 W, active production. CE marked. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Max.":"70 °C; = Tmax","Min.":"-25 °C; = Tmin","Depth":"52 mm","Width":"15 mm","title":"6AG1134-4JB51-7AB0","Height":"81 mm","Ni 100":"Yes; Standard/climate","Pt 100":"Yes; Standard/climate","CE mark":"Yes","Step: low":"Yes; 4x cycle time","Step: High":"Yes; 64x cycle time","Step: None":"Yes; 1x cycle time","Wire-break":"Yes","Group error":"Yes","description":"SIPLUS ET 200S EM 2AI RTD based on 6ES7134-4JB51-0AB0 with conformal coating, -25…+70 °C,","Step: Medium":"Yes; 32x cycle time","0 To 150 Ohms":"Yes","0 To 300 Ohms":"Yes","0 To 600 Ohms":"Yes","Shielded, Max.":"200 m","Parameterizable":"Yes; In four stages by means of digital filtering","Weight, approx.":"40 g","lifecycle_stage":"current","Isochronous mode":"No","Power loss, typ.":"0.6 W","Rated value (DC)":"24 V; From power module","Group diagnostics":"Disable / enable","Overflow/underflow":"Disable / enable","Between The Channels":"No","Group error SF (red)":"Yes","Integration time (ms)":"16,7 / 20 ms","Isolation tested with":"500 V DC","Measurement principle":"integrating","Diagnostics wire break":"Disable / enable","Number of analog inputs":"4; 2 for 3 or 4-wire connection","Input resistance (Ni 100)":"2 000 kΩ","Input resistance (Pt 100)":"2 000 kΩ","For Resistance Thermometer":"Pt100 (standard, climatic range), Ni100 (standard, climatic range)","Reverse polarity protection":"Yes","Conversion time (per channel)":"66 / 80 ms; additional conversion time for diagnostic wire break test","Address space per module, max.":"8 byte","Cycle time (all channels) max.":"Number of active channels per module x basic conversion time","Input resistance (0 to 150 ohms)":"2 000 kΩ","Input resistance (0 to 300 ohms)":"2 000 kΩ","Input resistance (0 to 600 ohms)":"2 000 kΩ","Integration time, parameterizable":"Yes","from backplane bus 3.3 V DC, max.":"10 mA","Between The Channels And Backplane Bus":"Yes","Between the channels and load voltage L+":"Yes","from load voltage L+ (without load), max.":"30 mA","Installation altitude above sea level, max.":"5 000 m","Product Function / Supply Voltage For Transmitters":"Yes","For Resistance Measurement With Two-Wire Connection":"Yes","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","For Resistance Measurement With Four-Wire Connection":"Yes","Resolution with overrange (bit including sign), max.":"16 bit; 150 ohms: 14 bit; 300, 600 ohms: 15 bit, Pt100, Ni100: 16 bit","For Resistance Measurement With Three-Wire Connection":"Yes","Technical unit for temperature measurement adjustable":"No","Resistance thermometer, relative to input range, (+/-)":"0.4 %","Constant measurement current for resistance-type transmitter, typ.":"1.67 mA","Interference voltage suppression for interference frequency f1 in Hz":"50 / 60 Hz","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"9 V","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$400.05","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e51396e92b3a763c69906944371f4bb2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=154281&mlfb=6AG1134-4JB51-7AB0"},"ai":{"faq":[{"question":"What is the temperature range for the 6AG1134-4JB51-7AB0?","answer":"The ambient operating and storage temperature range is -25 °C to 70 °C."},{"question":"What compliance markings does this module carry?","answer":"The module bears the CE mark."},{"question":"Can the input filtering be adjusted?","answer":"Yes, the module has parameterizable digital filtering in four stages: 1x, 4x, 32x, or 64x cycle time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1134-4JB51-7AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1134-4JB51-7AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}