{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1134-4LB02-2AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1134-4LB02-2AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1134-4LB02-2AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1134-4LB02-2AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 6AG1134-4LB02-2AB0 analog input module, 2 AI, voltage ranges ±10 V, ±5 V, 1-5 V, isochronous mode, 15 mm wide, active production.","salesMarkdown":"The 6AG1134-4LB02-2AB0: Two-channel analog voltage input for S7-1200 systems. Covers ±10 V, ±5 V, and 1 to 5 V ranges with 800 kΩ input resistance per channel. Conversion time runs 0.04 ms per channel without noise suppression; enable noise suppression and it stretches to 17/20 ms per channel. Isochronous mode is available for deterministic cyclic I/O. Module draws 0.85 W typical, 10 mA from the backplane. The 800 kΩ input resistance across all voltage ranges means minimal loading on the signal source – a thermocouple signal conditioner or 0-10 V transducer won't see a droop. Conversion time of 0.04 ms per channel (without noise suppression) is fast enough for most motion-control loops; if you need noise rejection on a long signal run, the per-channel 17/20 ms setting filters line-frequency ripple. Group diagnostics can be disabled to suppress nuisance alarms on unused channels. Reverse polarity protection on the 24 V DC supply prevents smoke when wiring up a new panel. No channel-to-channel isolation, but the design allows increased permissible potential difference between inputs – handy when one sensor floats higher than the rest. Parameterizable cycle time stages (1x, 4x, 16x, 32x) let you trade speed for filtering without a firmware change.","metaTitle":"Siemens 6AG1134-4LB02-2AB0 Analog Input, 2 AI, ±10V, 60°C","metaDescription":"Siemens 6AG1134-4LB02-2AB0 analog input module, 2 channels voltage ranges ±10V/±5V/1-5V, isochronous mode, 15 mm wide, active production. Sourced to order. RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Max.":"60 °C; = Tmax","Min.":"-25 °C; = Tmin","Depth":"52 mm","Width":"15 mm","title":"6AG1134-4LB02-2AB0","Height":"81 mm","Remark":"12 bytes, 4 bytes in compatibility mode","CE mark":"Yes","Step: low":"Yes; 4x","1 V to 5 V":"Yes","Step: High":"Yes; 32x","Step: None":"Yes; 1x","Wire-break":"Yes; Measuring range 1 to 5 V only","Group error":"Yes","description":"SIPLUS ET 200S EM 2AI HF based on 6ES7134-4LB02-0AB0 with conformal coating, -25…+60 °C, 2 AI U High Feature for ET 200S, 15 mm width, cycle time per module: 0.5 ms, +/-10 V; 15 bit+sign, +/-5 V; 15 bit+sign, 1..5 V; 15 bit, operational limit +/-0.1% with SF LED (group fault)","-5 V to +5 V":"Yes","Step: Medium":"Yes; 16x","-10 V to +10 V":"Yes","Shielded, Max.":"200 m","Parameterizable":"Yes; In 4 stages: 1x, 4x, 16x, 32x cycle time","Weight, approx.":"45 g","lifecycle_stage":"current","Isochronous mode":"Yes","Power loss, typ.":"0.85 W","Rated value (DC)":"24 V","Group diagnostics":"Disable / enable","Hardware interrupt":"Yes","Overflow/underflow":"Disable / enable","Between The Channels":"No; however, increased permissible potential difference between the inputs.","Group error SF (red)":"Yes","Isolation tested with":"500 V DC","For Voltage Measurement":"Yes","Number of analog inputs":"2","Reverse polarity protection":"Yes","Conversion time (per channel)":"0.04 ms; Without noise suppression 17/20 ms per channel with error","Input resistance (1 V to 5 V)":"800 kΩ","Address space per module, max.":"4 byte","Cycle time (all channels) max.":"0.5 ms; 0.5 ms for 2 channels without noise suppression, 18 / 21 ms per channel with noise suppression","Input resistance (-5 V to +5 V)":"800 kΩ","Input resistance (-10 V to +10 V)":"800 kΩ","Integration time, parameterizable":"Yes","from backplane bus 3.3 V DC, max.":"10 mA","Between The Channels And Backplane Bus":"Yes","Voltage, relative to input range, (+/-)":"0.05 %; 0.1% without interference frequency suppression","Between the channels and load voltage L+":"Yes","from load voltage L+ (without load), max.":"55 mA","Installation altitude above sea level, max.":"5 000 m","Product Function / Supply Voltage For Transmitters":"No","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resolution with overrange (bit including sign), max.":"16 bit; 0 to 5 V: 15 bit, ±10 V: 16 bit, ±5 V: 16 bit","Interference voltage suppression for interference frequency f1 in Hz":"60 / 50 Hz / no","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"35 V; 35 V continuous; 75 V for max. 1 ms","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$402.59","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e51396e92b3a763c69906944371f4bb2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=370931&mlfb=6AG1134-4LB02-2AB0"},"ai":{"faq":[{"question":"What is the maximum operating temperature for this module?","answer":"Rated for up to 60 °C ambient operating temperature."},{"question":"What is the minimum operating temperature?","answer":"Rated for down to -25 °C ambient operating temperature."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1134-4LB02-2AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1134-4LB02-2AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}