{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1134-6FF00-2AA1","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1134-6FF00-2AA1","canonicalUrl":"https://aoctrl.com/siemens/6AG1134-6FF00-2AA1","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1134-6FF00-2AA1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens ET 200SP analog input module 6AG1134-6FF00-2AA1, 8 x single-ended, 0..10 V / ±10 V, 15/16 bit resolution, 15 mm width, 24 V DC, active lifecycle.","salesMarkdown":"## 8 single-ended analog inputs, ±10 V or 0–10 V, 15/16 bit The Siemens 6AG1134-6FF00-2AA1 is an 8-channel analog input module for the ET 200SP system, accepting 0 to +10 V with 15-bit resolution or –10 to +10 V with 16-bit including sign. Each channel is single-ended, one AI per three terminals, so watch your common reference. Input resistance sits at 100 kΩ for the 0–10 V range. Conversion time per channel is configurable: 180 ms with smoothing, down to a fast 0.625 ms (67.5 ms for the full set at 180 ms setting). Four smoothing levels (none, 4/8/16 times) are parameterizable. For applications needing noise rejection over speed, the slower settings clean up the signal. Diagnostics are built in: a group error signal, diagnostic alarm, and monitoring of the 24 V DC supply with reverse polarity protection. Each channel's status shows via a green LED; a separate green/red DIAG LED covers module health. ## Panel integration – BaseUnit, space, and wiring Width is 15 mm, depth 58 mm, height 73 mm. Mounts onto a usable BaseUnit of type A0 or A1 (sold separately). When calculating ET 200SP station fill, budget 15 mm per analog module plus the BaseUnit width. Power draw: 25 mA max current consumption from the backplane, typical power loss 0.7 W. Maximum shielded cable length is 200 m – fine for most in-cabinet or local field wiring. The module supports I&M data (I&M0 to I&M3), firmware update capability, and is parameterizable. Operating temperature range: –40 °C to +60 °C horizontally installed; can stretch to +70 °C if empty slots are configured on either side. Derating applies beyond 60 °C, but the extra thermal margin helps in crowded cabinets.","metaTitle":"Siemens 6AG1134-6FF00-2AA1 Analog Input, 8-ch, 15/16 bit","metaDescription":"Active Siemens 6AG1134-6FF00-2AA1 analog input module for ET 200SP. 8 single-ended channels, 0–10 V (15 bit) and ±10 V (16 bit). 15 mm width, 24 V DC, diagnostics. Sourced to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"MSI":"No","Depth":"58 mm","Width":"15 mm","title":"6AG1134-6FF00-2AA1","Height":"73 mm","I&M data":"Yes; I&M0 to I&M3","0 to +10 V":"Yes; 15 bit","Wire-break":"No","Group error":"Yes","description":"SIPLUS ET 200SP AI 8xU Basic, based on 6ES7134-6FF00-0AA1 with conformal coating, -40…+60 °C, analog input module, suitable for BU type A0, A1, color code CC02, module diagnostics, 16 bit","Oversampling":"No","Short-circuit":"No","-10 V to +10 V":"Yes; 16 bit incl. sign","Shielded, Max.":"200 m","Parameterizable":"Yes","Weight, approx.":"31 g","lifecycle_stage":"current","Diagnostic alarm":"Yes","Isochronous mode":"No","Power loss, typ.":"0.7 W","Rated value (DC)":"24 V","usable BaseUnits":"BU type A0, A1","Limit value alarm":"No","FW update possible":"Yes","Overflow/underflow":"Yes","Between The Channels":"No","Diagnostics function":"Yes","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red DIAG LED","For Channel Diagnostics":"No","For Voltage Measurement":"Yes","Number of analog inputs":"8; Single-ended","Measuring range scalable":"No","Current consumption, max.":"25 mA","Number of smoothing levels":"4; None; 4/8/16 times","Calibration possible in RUN":"No","Reverse polarity protection":"Yes","Input resistance (0 to 10 V)":"100 kΩ","Conversion time (per channel)":"180 / 60 / 50 / 0.625 (67.5 / 22.5 / 18.75) ms","Horizontal Installation, Max.":"60 °C; = Tmax; +70 °C with configured empty slots to the left and right of the module","Horizontal Installation, Min.":"-40 °C; = Tmin (incl. condensation/frost)","Monitoring the supply voltage":"Yes","Address space per module, max.":"16 byte","Cycle time (all channels), min.":"1 ms; per channel","Input resistance (-10 V to +10 V)":"100 kΩ","Integration time, parameterizable":"Yes","Crosstalk between the inputs, min.":"-50 dB","Reparameterization possible in RUN":"Yes","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Between The Channels And Backplane Bus":"Yes","Voltage, relative to input range, (+/-)":"0.3 %","Monitoring of the supply voltage (PWR-LED)":"Yes; green PWR LED","Installation altitude above sea level, max.":"5 000 m","For Current Measurement As 4-Wire Transducer":"No","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Linearity error (relative to input range), (+/-)":"0.02 %","Temperature error (relative to input range), (+/-)":"0.009 %/K","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resolution with overrange (bit including sign), max.":"16 bit","Color code for module-specific color identification plate":"CC02","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Between The Channels And The Power Supply Of The Electronics":"No","Interference voltage suppression for interference frequency f1 in Hz":"16.67 / 50 / 60 / 4 800 (16.67 / 50 / 60)","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"30 V","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.05 %","Series mode interference (peak value of interference < rated value of input range), min.":"70 dB; With conversion time 67.5 / 22.5 / 18.75 ms: 40 dB","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$278.13","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e51396e92b3a763c69906944371f4bb2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=803928&mlfb=6AG1134-6FF00-2AA1"},"ai":{"faq":[{"question":"What BaseUnit does this module require?","answer":"It is compatible with BaseUnits type A0 or A1. The module itself is 15 mm wide, so plan its slot width accordingly."},{"question":"Does the module support diagnostics?","answer":"Yes, it reports a group error, supports diagnostic alarms, monitors the supply voltage, and has green channel status LEDs plus a green/red DIAG LED for module diagnostics."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1134-6FF00-2AA1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1134-6FF00-2AA1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}