{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1134-6GD00-7BA1","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1134-6GD00-7BA1","canonicalUrl":"https://aoctrl.com/siemens/6AG1134-6GD00-7BA1","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1134-6GD00-7BA1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 6AG1134-6GD00-7BA1, ET 200SP analog input module, 4 AI, 24 V DC, I&M data, ±20 mA, BaseUnits A0/A1, current production.","salesMarkdown":"## Siemens 6AG1134-6GD00-7BA1: 4-Channel Analog Input Module, Current Production Diagnostic capabilities include a group error LED, per-channel status LEDs, diagnostic alarm, and overflow/underflow detection. Short-circuit protection is built in for 2-wire mode, covering encoder supply shorts to ground or an input to the encoder supply. I&M data (I&M0 through I&M3) is supported for asset management. The module is parameterizable, with up to four smoothing levels (none, 4x, 8x, 16x) and measurement based on an integrating Sigma-Delta principle. ## Mounting and Layout with BaseUnits A0/A1 This module occupies a 15 mm wide slot and mates with BaseUnits type A0 or A1, common in ET 200SP distributed I/O systems. Depth is 58 mm, height 73 mm, allowing dense packing on standard DIN rails. Shielded cable runs up to 1 000 m are supported. Typical power dissipation is 0.85 W without encoder supply voltage, maximum current draw is 37 mA without sensor supply, and short-circuit protection covers the encoder supply to ground or an input to the encoder supply with a max. 50 mA per channel for a duration < 10 s. Isolation is tested at 707 V DC type test, with a common-mode voltage limit of 10 V DC between inputs.","metaTitle":"Siemens 6AG1134-6GD00-7BA1 4AI Analog Input Module, Active","metaDescription":"Active production Siemens 6AG1134-6GD00-7BA1 4-channel analog input module for 24V systems. I&M data, wire-break detection, ±20mA input. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"MSI":"No","24 V":"Yes","Depth":"58 mm","Width":"15 mm","title":"6AG1134-6GD00-7BA1","Height":"73 mm","I&M data":"Yes; I&M0 to I&M3","0 to 20 mA":"Yes","Wire-break":"Yes; at 4 to 20 mA","Group error":"Yes","description":"***SPARE PART*** SIPLUS ET 200SP, Analog input module, AI 4XI 2-/4-wire Standard, -40...+70°C with conformal coating based on 6ES7134-6GD00-0BA1. suitable for BU type A0, A1, Color code CC03, Module diagnostics, 16 bit, +/-0.3%","Oversampling":"No","4 mA to 20 mA":"Yes","Short-circuit":"Yes; 2-wire mode: Short-circuit of the encoder supply to ground or of an input to the encoder supply","Shielded, Max.":"1 000 m","Parameterizable":"Yes","Weight, approx.":"31 g","lifecycle_stage":"current","-20 mA to +20 mA":"Yes","Diagnostic alarm":"Yes","Isochronous mode":"No","Power loss, typ.":"0.85 W; Without encoder supply voltage","Rated value (DC)":"24 V","usable BaseUnits":"BU type A0, A1","Limit value alarm":"No","Overflow/underflow":"Yes","Between The Channels":"Yes; channel group-specific between 2-wire current input group and 4-wire voltage input group","Diagnostics function":"Yes","Output current, max.":"20 mA; max. 50 mA per channel for a duration < 10 s","Isolation tested with":"707 V DC (type test)","Measurement principle":"integrating (Sigma-Delta)","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red LED","For Channel Diagnostics":"No","For Voltage Measurement":"No","Number of analog inputs":"4; > 60 °C max. 1x ±20 mA permissible","Measuring range scalable":"No","Short-circuit protection":"Yes","between the inputs (UCM)":"10 V DC","Common mode voltage, max.":"10 V","Current consumption, max.":"37 mA; without sensor supply","Number of smoothing levels":"4; None; 4/8/16 times","Calibration possible in RUN":"No","Reverse polarity protection":"Yes","Vertical Installation, Max.":"50 °C; = Tmax","Vertical Installation, Min.":"-40 °C; = Tmin","Conversion time (per channel)":"180 / 60 / 50 ms","Horizontal Installation, Max.":"70 °C; = Tmax; > 60 °C max. 1x ±20 mA permissible","Horizontal Installation, Min.":"-40 °C; = Tmin","Input resistance (0 to 20 mA)":"100 Ω; + approx. 0.7 V diode forward voltage in 2-wire operation","Monitoring the supply voltage":"Yes","Address space per module, max.":"8 byte; + 1 byte for QI information","Common mode interference, min.":"90 dB","Cycle time (all channels), min.":"Sum of the basic conversion times and additional processing times (depending on the parameterization of the active channels)","Input resistance (4 mA to 20 mA)":"100 Ω; + approx. 0.7 V diode forward voltage in 2-wire operation","Integration time, parameterizable":"Yes","Burden of 2-wire transmitter, max.":"650 Ω","Crosstalk between the inputs, min.":"50 dB; Applies to up to ±5 V overvoltage in other channels","Reparameterization possible in RUN":"Yes","Input resistance (-20 mA to +20 mA)":"100 Ω","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Between The Channels And Backplane Bus":"Yes","Current, relative to input range, (+/-)":"0.3 %","Monitoring of the supply voltage (PWR-LED)":"Yes; green LED","Installation altitude above sea level, max.":"5 000 m","For Current Measurement As 2-Wire Transducer":"Yes","For Current Measurement As 4-Wire Transducer":"Yes","Linearity error (relative to input range), (+/-)":"0.01 %","Temperature error (relative to input range), (+/-)":"0.005 %/K","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resolution with overrange (bit including sign), max.":"16 bit","Color code for module-specific color identification plate":"CC03","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Between The Channels And The Power Supply Of The Electronics":"Yes; only for 4-wire transducer","Interference voltage suppression for interference frequency f1 in Hz":"16.6 / 50 / 60 Hz","Permissible Input Current For Current Input (Destruction Limit), Max.":"50 mA","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.05 %","Series mode interference (peak value of interference < rated value of input range), min.":"70 dB","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e51396e92b3a763c69906944371f4bb2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=315088&mlfb=6AG1134-6GD00-7BA1"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1134-6GD00-7BA1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1134-6GD00-7BA1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}