{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1134-6HB00-2DA1","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1134-6HB00-2DA1","canonicalUrl":"https://aoctrl.com/siemens/6AG1134-6HB00-2DA1","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1134-6HB00-2DA1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC ET 200SP analog input module, 6AG1134-6HB00-2DA1, 2-channel, 16-bit, 24 V DC","salesMarkdown":"The Siemens 6AG1134-6HB00-2DA1 is a 2-channel analog input module for the ET 200SP distributed I/O system. It handles voltage and current signals across multiple ranges, with 16-bit resolution on the ±10 V range and 16-bit including sign on the ±20 mA range. Oversampling is supported on both channels, and isochronous mode enables time-synchronized acquisition for motion or high-speed processes. The module occupies 15 mm on the DIN rail and requires a BU type A0 or A1 base unit. Supply is 24 V DC with typical power draw of 0.95 W without sensor supply. Resolution across ranges: the 16-bit ±10 V range and the 16-bit ±20 mA range offer the widest dynamic range. For applications needing channel-by-channel wire-break detection, this only works in 4–20 mA mode. Short-circuit detection is available on voltage ranges and current encoder supply. The module can oversample each cycle with up to 16 values per cycle, and firmware is updatable. Diagnostic alarms, limit value alarms, and group error outputs are built-in. A green LED per channel shows status, and a red LED per channel indicates diagnostics.","metaTitle":"Siemens 6AG1134-6HB00-2DA1 Analog Input Module, 16-bit","metaDescription":"Siemens 6AG1134-6HB00-2DA1 analog input module for ET 200SP; 2 channels, 16-bit resolution, voltage/current ranges, isochronous mode, active production. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"MSI":"No","24 V":"Yes","Depth":"58 mm","Width":"15 mm","title":"6AG1134-6HB00-2DA1","Height":"73 mm","I&M data":"Yes; I&M0 to I&M3","0 to +10 V":"Yes; 15 bit","0 to 20 mA":"Yes; 15 bit","1 V to 5 V":"Yes; 13 bit","Wire-break":"Yes; channel-by-channel, at 4 to 20 mA only","Group error":"Yes","description":"SIPLUS ET 200SP AI 2xU/I 2-, 4-wire HS based on 6ES7134-6HB00-0DA1 with conformal coating, -40…+60 °C, analog input module, suitable for BU type A0, A1, color code CC00, channel diagnostics, 16-bit, +/-0.3%","-5 V to +5 V":"Yes; 15 bit incl. sign","Oversampling":"Yes; 2 channels per module","4 mA to 20 mA":"Yes; 14 bit","Short-circuit":"Yes; channel-by-channel, at 1 to 5 V or for current measuring ranges short-circuit in encoder supply","-10 V to +10 V":"Yes; 16 bit incl. sign","Shielded, Max.":"1 000 m; 200 m for voltage measurement","Parameterizable":"Yes","Weight, approx.":"32 g","lifecycle_stage":"current","-20 mA to +20 mA":"Yes; 16 bit incl. sign","Diagnostic alarm":"Yes","Firmware version":"V2.0","Isochronous mode":"Yes","Power loss, typ.":"0.95 W; without sensor supply","Rated value (DC)":"24 V","Resolution, min.":"50 µs","usable BaseUnits":"BU type A0, A1","Limit value alarm":"Yes; two upper and two lower limit values in each case","FW update possible":"Yes","Overflow/underflow":"Yes","Between The Channels":"Yes","Output current, max.":"20 mA; max. 50 mA per channel for a duration < 10 s","Isolation tested with":"707 V DC (type test)","Measurement principle":"Actual value encryption (successive approximation)","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red DIAG LED","Values per cycle, max.":"16","For Channel Diagnostics":"Yes; red LED","For Voltage Measurement":"Yes","Number of analog inputs":"2; Differential inputs","Measuring range scalable":"No","Short-circuit protection":"Yes","between the inputs (UCM)":"75 V DC/60 V AC","Common mode voltage, max.":"35 V","Between Different Circuits":"75 V DC/60 V AC (base isolation)","Bus cycle time (TDP), min.":"125 µs","Number of smoothing levels":"7; none; 2-/4-/8-/16-/32-/64-fold","Calibration possible in RUN":"No","Reverse polarity protection":"Yes","Input resistance (0 to 10 V)":"75 kΩ","Conversion time (per channel)":"10 µs","Horizontal Installation, Max.":"60 °C; = Tmax; +70 °C with configured empty slots to the left and right of the module","Horizontal Installation, Min.":"-40 °C; = Tmin (incl. condensation/frost)","Input resistance (0 to 20 mA)":"130 Ω","Input resistance (1 V to 5 V)":"75 kΩ","Address space per module, max.":"4 byte; + 1 byte for QI information (32 bytes in the oversampling operating mode)","Analog input with oversampling":"Yes","Common mode interference, min.":"90 dB","Cycle time (all channels), min.":"125 µs","Input resistance (-5 V to +5 V)":"75 kΩ","Input resistance (4 mA to 20 mA)":"130 Ω","Current consumption (rated value)":"39 mA; without sensor supply","Input resistance (-10 V to +10 V)":"75 kΩ","Burden of 2-wire transmitter, max.":"650 Ω","Crosstalk between the inputs, min.":"-50 dB","Reparameterization possible in RUN":"Yes","Input resistance (-20 mA to +20 mA)":"130 Ω","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Between The Channels And Backplane Bus":"Yes","Current, relative to input range, (+/-)":"0.2 %","Voltage, relative to input range, (+/-)":"0.2 %","Filtering and processing time (TCI), min.":"80 µs","Monitoring of the supply voltage (PWR-LED)":"Yes; green PWR LED","Installation altitude above sea level, max.":"5 000 m","For Current Measurement As 2-Wire Transducer":"Yes","For Current Measurement As 4-Wire Transducer":"Yes","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Linearity error (relative to input range), (+/-)":"0.03 %","Temperature error (relative to input range), (+/-)":"0.01 %/K","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resolution with overrange (bit including sign), max.":"16 bit","Color code for module-specific color identification plate":"CC00","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Between The Channels And The Power Supply Of The Electronics":"Yes","Interference voltage suppression for interference frequency f1 in Hz":"No","Permissible Input Current For Current Input (Destruction Limit), Max.":"50 mA","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"30 V","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.1 %","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$342.90","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e51396e92b3a763c69906944371f4bb2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=579075&mlfb=6AG1134-6HB00-2DA1"},"ai":{"faq":[{"question":"What is the MSI (Manufacturer-specific information) value for this module?","answer":"The MSI field is listed as 'No'."},{"question":"Does the module operate on 24 V?","answer":"Yes, the rated value (DC) is 24 V."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1134-6HB00-2DA1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1134-6HB00-2DA1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}