{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1134-6JD00-2DA1","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1134-6JD00-2DA1","canonicalUrl":"https://aoctrl.com/siemens/6AG1134-6JD00-2DA1","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1134-6JD00-2DA1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS ET 200SP analog input module, 8-channel thermocouple/voltage, 16-bit signed, MSI enabled, 24 VDC, 0.9 W.","salesMarkdown":"## Module identity and key ratings The 6AG1134-6JD00-2DA1: Each channel is independently configurable, enabling a mix of thermocouple types and voltage inputs within the same module. The module includes diagnostic alarms, wire-break detection per channel, and limit-value alarms (two upper and two lower) — useful for process monitoring without extra programming. ## Fit for the BOM line This is the ruggedized SIPLUS version — same electrical functionality as the standard ET 200SP AI but qualified for extended temperature and aggressive atmospheres. If your application calls for the standard version, the 6AG1 prefix signals the tougher variant. Supported thermocouple types include B, C, E, J, K, L, N, R, S, T, and U — all with 16-bit signed resolution. Voltage inputs span ±1 V down to ±50 mV, suitable for shunt-equipped current sensors or millivolt transducers. ## Integration dimensions Width is 15 mm, depth 58 mm, height 73 mm — occupies a single slot on the ET 200SP base unit (BU type A0 or A1). Uses a 2-wire connection; shielded cable up to 200 m for voltage, 100 m for thermocouples. Power consumption is 0.9 W typical from the 24 VDC backplane, so total PSU budget remains low even in multi-module racks. MSI is supported (I&M0 to I&M3) for electronic nameplate and maintenance tracking — useful for asset management in large installations.","metaTitle":"Siemens 6AG1134-6JD00-2DA1 SIPLUS 8AI TC/Voltage, 16-bit","metaDescription":"Active production, thermocouple module for ET 200SP, 8 channels, 16-bit signed, MSI enabled, 24 VDC, 0.9 W. Source via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"MSI":"Yes","Depth":"58 mm","Width":"15 mm","title":"6AG1134-6JD00-2DA1","Height":"73 mm","Type B":"Yes; 16 bit incl. sign","Type C":"Yes; 16 bit incl. sign","Type E":"Yes; 16 bit incl. sign","Type J":"Yes; 16 bit incl. sign","Type K":"Yes; 16 bit incl. sign","Type L":"Yes; 16 bit incl. sign","Type N":"Yes; 16 bit incl. sign","Type R":"Yes; 16 bit incl. sign","Type S":"Yes; 16 bit incl. sign","Type T":"Yes; 16 bit incl. sign","Type U":"Yes; 16 bit incl. sign","I&M data":"Yes; I&M0 to I&M3","Step: low":"Yes","Step: High":"Yes","Step: None":"Yes","Wire-break":"Yes; channel by channel","Group error":"Yes","description":"SIPLUS ET 200SP AI 4xTC HS based on 6ES7134-6JD00-0DA1 with conformal coating, -40…+60 °C, analog input module, suitable for BU type A0, A1, color code CC00, channel diagnostics, 16 bit, +/-0.1%,","-1 V to +1 V":"Yes; 16 bit incl. sign","Oversampling":"No","Step: Medium":"Yes","Shielded, Max.":"200 m; 100 m for thermocouples","Parameterizable":"Yes","Weight, approx.":"33 g","lifecycle_stage":"current","-50 mV to +50 mV":"Yes; 16 bit incl. sign","-80 mV to +80 mV":"Yes; 16 bit incl. sign","Diagnostic alarm":"Yes","Isochronous mode":"No","Power loss, typ.":"0.9 W","Rated value (DC)":"24 V","usable BaseUnits":"BU type A0, A1","2-Wire Connection":"BU type A0, A1","Limit value alarm":"Yes; two upper and two lower limit values in each case","-250 mV to +250 mV":"Yes; 16 bit incl. sign","Automatic encoding":"Yes","FW update possible":"Yes","Overflow/underflow":"Yes; channel by channel","Between The Channels":"No","Diagnostics function":"Yes","Isolation tested with":"707 V DC (type test)","Measurement principle":"integrating (Sigma-Delta)","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red LED","For Channel Diagnostics":"Yes; red LED","For Voltage Measurement":"Yes","Number of analog inputs":"4","Type TXK/TXK(L) to GOST":"Yes; 16 bit incl. sign","Measuring range scalable":"Yes","between the inputs (UCM)":"60 V DC","Common mode voltage, max.":"60 V; DC","Current consumption, max.":"50 mA","Input resistance (Type B)":"1 MΩ","Input resistance (Type C)":"1 MΩ","Input resistance (Type E)":"1 MΩ","Input resistance (Type K)":"1 MΩ","Input resistance (Type L)":"1 MΩ","Input resistance (Type N)":"1 MΩ","Input resistance (Type R)":"1 MΩ","Input resistance (Type S)":"1 MΩ","Input resistance (Type T)":"1 MΩ","Input resistance (Type U)":"1 MΩ","Input resistance (type J)":"1 MΩ","Internal Comparison Point":"Yes; with BaseUnit type A1","Mechanical coding element":"Yes","Number of smoothing levels":"4; None; 4/8/16 times","Calibration possible in RUN":"Yes","Fixed Reference Temperature":"Yes","Reverse polarity protection":"Yes","Vertical Installation, Max.":"50 °C; = Tmax","Vertical Installation, Min.":"-40 °C; = Tmin (incl. condensation/frost)","Conversion time (per channel)":"180/60/50/1.25 ms","Horizontal Installation, Max.":"60 °C; = Tmax; +70 °C with configured empty slots to the left and right of the module","Horizontal Installation, Min.":"-40 °C; = Tmin (incl. condensation/frost)","Monitoring the supply voltage":"Yes","Address space per module, max.":"16 byte; + 1 byte for QI information","Common mode interference, min.":"90 dB","Reference channel of the group":"Yes","Cycle time (all channels), min.":"5 ms; Sum of the basic conversion times and additional processing times (depending on the parameterization of the active channels)","Input resistance (-1 V to +1 V)":"1 MΩ","Reference channel of the module":"No","Current consumption (rated value)":"37 mA","Integration time, parameterizable":"Yes","Type of mechanical coding element":"Type A","Crosstalk between the inputs, min.":"-70 dB","Number of reference channel groups":"4; Group 0 to 3","Reparameterization possible in RUN":"Yes","Input resistance (-50 mV to +50 mV)":"1 MΩ","Input resistance (-80 mV to +80 mV)":"1 MΩ","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Input resistance (-250 mV to +250 mV)":"1 MΩ","Between The Channels And Backplane Bus":"Yes","PROFIBUS from GSD version/GSD revision":"One GSD file each, Revision 3 and 5 and higher","PROFINET from GSD version/GSD revision":"GSDML V2.3","Voltage, relative to input range, (+/-)":"0.05 %; 0.2 % when SFU OFF","Input resistance (Type TXK/TXK(L) to GOST)":"1 MΩ","Monitoring of the supply voltage (PWR-LED)":"Yes; green PWR LED","Installation altitude above sea level, max.":"5 000 m","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Additional Processing Time For Wire-Break Check":"1 ms","Linearity error (relative to input range), (+/-)":"0.01 %","Temperature error (relative to input range), (+/-)":"0.005 %/K","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resolution with overrange (bit including sign), max.":"16 bit","Technical unit for temperature measurement adjustable":"Yes; °C/°F/K","Color code for module-specific color identification plate":"CC00","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Between The Channels And The Power Supply Of The Electronics":"Yes","Interference voltage suppression for interference frequency f1 in Hz":"16.6 / 50 / 60 Hz / off","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"30 V","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.03 %","Series mode interference (peak value of interference < rated value of input range), min.":"70 dB","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e51396e92b3a763c69906944371f4bb2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1542933&mlfb=6AG1134-6JD00-2DA1"},"ai":{"faq":[{"question":"What thermocouple types does this module support?","answer":"It supports types B, C, E, J, K, L, N, R, S, T, and U — all with 16-bit signed resolution."},{"question":"What is the physical size of this module?","answer":"Width 15 mm, depth 58 mm, height 73 mm. It fits any ET 200SP base unit type A0 or A1."},{"question":"Does it include diagnostic capabilities?","answer":"Yes — diagnostic alarms, wire-break detection per channel, and limit-value alarms with two upper and two lower thresholds."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1134-6JD00-2DA1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1134-6JD00-2DA1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}