{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1134-6PA00-7BD0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1134-6PA00-7BD0","canonicalUrl":"https://aoctrl.com/siemens/6AG1134-6PA00-7BD0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1134-6PA00-7BD0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS S7-1200 analog input module, 6AG1134-6PA00-7BD0, 58 mm depth, 20 mm width, 100-240 VAC, ±1% accuracy on power, current, voltage.","salesMarkdown":"Siemens 6AG1134-6PA00-7BD0 is a SIPLUS S7-1200 analog input module dedicated to electrical energy measurement — voltage, current, frequency, active and reactive power, all with ±1% accuracy. It's the module for submetering or power-quality monitoring inside a SIMATIC rack. Power for the module comes directly from the voltage measurement channel L1, so no separate 24 VDC supply is needed — just the 100-240 VAC line being measured. That simplifies wiring in retrofit panels. Width is 20 mm, depth 58 mm — it takes one base unit slot (BU type D0). Horizontal mounting (standard) lets the module run up to 70 °C ambient; above 60 °C, limit load current to 1 A per phase. Vertical installation caps at 50 °C. Cold start from -40 °C is fine, but below -25 °C the supply voltage must be at least 110 V AC. ## What you get out of it Parameter length per module is 44 bytes (32 input, 12 output). Supports cyclic and acyclic measurement, diagnostic and channel alarms. I&M data included. No isochronous mode — this is for monitoring, not motion control. One thing to note: zero-point suppression is set at 50 mA, meaning currents below that threshold are reported as zero — fine for submetering but if you need to log micro-loads, account for that floor. Voltage measurement handles sinusoidal or distorted waveforms from 45 to 65 Hz. Accuracy for power, current, and voltage is ±1.0%.","metaTitle":"Siemens 6AG1134-6PA00-7BD0 S7-1200 Analog Input, 58 mm depth","metaDescription":"Siemens SIPLUS S7-1200 analog input module for energy monitoring. Active lifecycle. 100-240 VAC, ±1% accuracy, 20 mm wide. Sourced per RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Depth":"58 mm","Width":"20 mm","title":"6AG1134-6PA00-7BD0","Height":"73 mm","I&M data":"Yes","description":"***spare part*** SIPLUS ET 200SP AI Energy Meter based on 6ES7134-6PA00-0BD0 with conformal coating, -40…+70 °C, start up -25 °C, analog input module, suitable for BU type D0, color code CC00, channel diagnostics","Surge strength":"10 A; for 1 minute","Weight, approx.":"45 g","lifecycle_stage":"current","Diagnostic alarm":"Yes","Isochronous mode":"No","Parameter length":"44 byte","Rated value (AC)":"100 - 240 V AC","usable BaseUnits":"BU type D0","Limit value alarm":"No","Mounting position":"Horizontal","Cyclic Measurement":"Yes","Energy measurement":"Yes","Acyclic Measurement":"Yes","Current measurement":"Yes","Voltage measurement":"Yes","Frequency measurement":"Yes","Channel status display":"Yes","Curve shape of voltage":"Sinusoidal or distorted","For Module Diagnostics":"Yes","Zero point suppression":"50 mA","For Channel Diagnostics":"Yes","Active power measurement":"Yes","Design of the power supply":"Supply via voltage measurement channel L1","Reactive power measurement":"Yes","For Measured Variable Power":"±1.0%","Frequency measurement, max.":"65 Hz","Frequency measurement, min.":"45 Hz","Power consumption per phase":"20 mW","Vertical Installation, Max.":"50 °C; = Tmax","Vertical Installation, Min.":"-40 °C; = Tmin; Startup @ -25 °C","For Measured Variable Current":"±1.0%","For Measured Variable Voltage":"±1.0%","Horizontal Installation, Max.":"70 °C; = Tmax; > +60 °C max. permissible current 1 A per phase","Horizontal Installation, Min.":"-40 °C; = Tmin; < -25 °C min. permissible supply voltage 110 V AC","Address space per module, max.":"44 byte; 32 byte input / 12 byte output","Permissible Range, Lower Limit":"47 Hz","Permissible Range, Upper Limit":"63 Hz","Buffering of measured variables":"No","Cycle time (all channels), typ.":"50 ms","For Measured Variable Active Power":"±1.0%","Type of measured value acquisition":"seamless","permissible range, lower limit (AC)":"90 V","permissible range, upper limit (AC)":"264 V","For Measured Variable Reactive Power":"±1.0%","measurable relative current (AC), max.":"100 %; Relative to the secondary rated current; 1 A, 5 A","measurable relative current (AC), min.":"5 %; Relative to the secondary rated current; 1 A, 5 A","For Measured Variable Total Active Energy":"Class 1 acc. to IEC 62053-21:2003","Monitoring of the supply voltage (PWR-LED)":"Yes","Burden power current transformer x/1A, min.":"1.25 VA","Burden power current transformer x/5A, min.":"1.5 VA","For Measured Variable Total Reactive Energy":"Class 2 acc. to IEC 62053-23:2003","Installation altitude above sea level, max.":"3 000 m","Measuring procedure for current measurement":"TRMS","Measuring procedure for voltage measurement":"TRMS","Measurement category for voltage measurement":"CAT III acc. to IEC 61010 Part 1","Reference condition for measurement accuracy":"Symmetric load, rated current: 20-100%, 50 Hz; active power: LF = 1, reactive power: LF = 0","Continuous current with AC, maximum permissible":"5 A","Power consumption without expansion module, typ.":"0.6 VA","Measurable line voltage between the line conductors":"400 V","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... Tmax -5K) at 795 hPa ... 701 hPa (+2 000 m ... +3 000 m)","Relative Symmetrical Tolerance Of The Supply Voltage":"10 %","Resolution with overrange (bit including sign), max.":"24 bit; Sigma-delta converter, 1.024 MHz","STEP 7 TIA Portal configurable/integrated from version":"see entry ID: 109746275","Color code for module-specific color identification plate":"CC00","Measurable line voltage between the line conductors, max.":"460 V","Measurable line voltage between the line conductors, min.":"155 V","Rated value short-time withstand current restricted to 1 s":"100 A","Measurable line voltage between phase and neutral conductor":"230 V","Apparent power consumption per phase for measuring range 5 A":"0.6 VA","Cable length (terminal-transformer) dependent on Zn and Imax":"200 m","Measurable line voltage between phase and neutral conductor, max.":"264 V","Measurable line voltage between phase and neutral conductor, min.":"90 V"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e51396e92b3a763c69906944371f4bb2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=424064&mlfb=6AG1134-6PA00-7BD0"},"ai":{"faq":[{"question":"What temperature range does it support in horizontal mounting?","answer":"Rated -40 °C to 70 °C horizontal, but above 60 °C the per-phase current is limited to 1 A."},{"question":"Does it need a separate power supply?","answer":"No, it's powered through the L1 voltage measurement channel at 100-240 VAC."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1134-6PA00-7BD0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1134-6PA00-7BD0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}