{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1135-6HB00-7CA1","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1135-6HB00-7CA1","canonicalUrl":"https://aoctrl.com/siemens/6AG1135-6HB00-7CA1","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1135-6HB00-7CA1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS 6AG1135-6HB00-7CA1 analog output module, 2 analog outputs, -10 to +10 V 16-bit, 24 V DC, active lifecycle, 58 mm depth.","salesMarkdown":"## Two-Channel Analog Output for ET 200SP The Siemens SIPLUS 6AG1135-6HB00-7CA1 is a 2-channel analog output module for the ET 200SP distributed I/O system. It covers voltage and current ranges with 16-bit resolution on the ±10 V range, 15-bit on 0–10 V and ±20 mA, and 14-bit on 4–20 mA. Jitter is rated at 5 µs, making it suitable for isochronous mode applications. Power consumption is 0.9 W typical. The module mounts on BU type A0 or A1 base units. ## Wiring and Diagnostics Each output channel can be independently configured for voltage or current. Wire-break detection works only on current outputs; short-circuit detection only on voltage outputs. Reaction time is 0.05 ms for resistive, inductive, and capacitive loads (capacitive limited to 20 m cable length and 47 nF). Diagnostic alarm, group error, and channel-specific red LED indicators are included. I&M0–I&M3 data is stored for asset tracking. Isolation is tested at 707 V DC type test.","metaTitle":"Siemens 6AG1135-6HB00-7CA1 SIPLUS 2AO Analog Output, 16-bit","metaDescription":"Siemens 6AG1135-6HB00-7CA1 SIPLUS analog output module with 2 channels, ±10 V 16-bit, 24 V DC. Active lifecycle, 5 µs jitter, I&M data, diagnostic alarms. RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"MSO":"No","Depth":"58 mm","Width":"15 mm","title":"6AG1135-6HB00-7CA1","Height":"73 mm","I&M data":"Yes; I&M0 to I&M3","0 to 10 V":"Yes; 15 bit","0 to 20 mA":"Yes; 15 bit","1 V to 5 V":"Yes; 13 bit","Wire-break":"Yes; channel-by-channel, only for output type \"current\"","Group error":"Yes","description":"SIPLUS ET 200SP AQ 2xU/I HF based on 6ES7135-6HB00-0CA1 with conformal coating, -40…+70 °C, analog output module, suitable for BU type A0, A1, color code CC00, channel diagnostics, 16-bit, +/-0.1%","-5 V to +5 V":"Yes; 15 bit incl. sign","Jitter, max.":"5 µs","Oversampling":"No","4 mA to 20 mA":"Yes; 14 bit","Short-circuit":"Yes; channel-by-channel, only for output type \"voltage\"","-10 V to +10 V":"Yes; 16 bit incl. sign","Shielded, Max.":"1 000 m; 200 m for voltage output","Weight, approx.":"31 g","lifecycle_stage":"current","-20 mA to +20 mA":"Yes; 16 bit incl. sign","Diagnostic alarm":"Yes","Isochronous mode":"Yes","Power loss, typ.":"0.9 W","Rated value (DC)":"24 V","usable BaseUnits":"BU type A0, A1","For Inductive Load":"0.05 ms","For Resistive Load":"0.05 ms","Overflow/underflow":"Yes","For Capacitive Load":"0.05 ms; Max. 47 nF and 20 m cable length","Between The Channels":"No","Diagnostics function":"Yes","Isolation tested with":"707 V DC (type test)","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red DIAG LED","For Channel Diagnostics":"Yes; red LED","Voltages at the outputs":"30 V","Number of analog outputs":"2","Current consumption, max.":"90 mA; 2 channels current output 20 mA","Bus cycle time (TDP), min.":"750 µs","With Current Outputs, Max.":"500 Ω","With Voltage Outputs, Min.":"2 kΩ","Calibration possible in RUN":"Yes","Reverse polarity protection":"Yes","Vertical Installation, Max.":"60 °C; = Tmax","Vertical Installation, Min.":"-40 °C; = Tmin","Horizontal Installation, Max.":"70 °C; = Tmax","Horizontal Installation, Min.":"-40 °C; = Tmin (incl. condensation/frost)","Monitoring the supply voltage":"Yes","Substitute values connectable":"Yes","Address space per module, max.":"4 byte; + 1 byte for QI information","Cycle time (all channels), min.":"750 µs","Current consumption (rated value)":"45 mA; without load","Reparameterization possible in RUN":"Yes","Crosstalk between the outputs, max.":"-50 dB","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Between The Channels And Backplane Bus":"Yes","For Current Output Two-Wire Connection":"Yes","For Voltage Output Two-Wire Connection":"Yes","For Voltage Output Four-Wire Connection":"Yes","Current, relative to output range, (+/-)":"0.1 %","Voltage output, short-circuit protection":"Yes","Voltage, relative to output range, (+/-)":"0.1 %","Execution and activation time (TCO), min.":"500 µs","Monitoring of the supply voltage (PWR-LED)":"Yes; green PWR LED","With Current Outputs, Inductive Load, Max.":"1 mH","Installation altitude above sea level, max.":"5 000 m","Voltage output, short-circuit current, max.":"45 mA","With Voltage Outputs, Capacitive Load, Max.":"1 µF","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Linearity error (relative to output range), (+/-)":"0.03 %","Temperature error (relative to output range), (+/-)":"0.003 %/K","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resolution with overrange (bit including sign), max.":"16 bit","Color code for module-specific color identification plate":"CC00","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Between The Channels And The Power Supply Of The Electronics":"Yes","Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-)":"0.02 %","Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)":"0.03 %","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$243.84","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e51396e92b3a763c69906944371f4bb2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1265790&mlfb=6AG1135-6HB00-7CA1"},"ai":{"faq":[{"question":"What is the MSO (Minimum Separator Overhead) for this module?","answer":"MSO is not supported – listed as No."},{"question":"Does it support diagnostic alarms?","answer":"Yes, it supports diagnostic alarm, group error, and channel diagnostics with red LED indicators."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1135-6HB00-7CA1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1135-6HB00-7CA1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}