{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1136-6AA00-2CA1","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1136-6AA00-2CA1","canonicalUrl":"https://aoctrl.com/siemens/6AG1136-6AA00-2CA1","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1136-6AA00-2CA1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS ET 200SP AI 4xI 2-/4-wire HF, 4 analog inputs, 0/4-20 mA, 24 V DC, SIL 3, 15 mm, life cycle current.","salesMarkdown":"Siemens 6AG1136-6AA00-2CA1 is a SIPLUS ET 200SP analog input module with four channels for 4 to 20 mA current signals. It runs on 24 V DC supply with min. L+ margin of –1.5 V, rated SIL 3, 15 mm wide, and fits on BU type A0 or A1. These channels are parameterizable for conversion speed (1× to 64× oversampling) and include wire-break detection on the 4 to 20 mA range. Short-circuit protection and a diagnostic alarm come standard, so you get a clean signal or a clear fault flag. And the sigma-delta measurement principle keeps noise out of the conversion — it's the right architecture for a plant floor with drives and contactors nearby. ## Signal integrity and diagnostics Shielded cable runs up to 1 000 m are supported. The module's green RUN LED and red ERROR LED give a quick status check, and diagnostic alarms indicate channel faults including wire-break. Lifecycle stage is marked as current — SIPLUS modules are typically produced in active runs for harsh-environment applications. No last-time-buy or phase-out flags here. That means you can spec this line into a BOM freeze without worrying about an imminent EOL. Sourcing is handled via RFQ against your exact quantity; we can quote firm lead times for this active code.","metaTitle":"Siemens 6AG1136-6AA00-2CA1 SIPLUS ET 200SP AI 4xI, SIL 3","metaDescription":"SIPLUS analog input module, 4 channels, 0/4-20 mA, 24V supply, SIL 3, 15mm wide. Active production. Source via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"24 V":"Yes; min. L+ (-1.5 V)","Depth":"58 mm","Width":"15 mm","title":"6AG1136-6AA00-2CA1","Height":"73 mm","Inputs":"14 byte; S7-300/400F CPU, 13 byte","Outputs":"5 byte; S7-300/400F CPU, 4 byte","RUN LED":"Yes; green LED","I&M data":"Yes; I&M0 to I&M3","ERROR LED":"Yes; red LED","Step: low":"Yes; 2x / 4x conversion cycle time","0 to 20 mA":"Yes","Step: High":"Yes; 32x / 64x conversion cycle time","Step: None":"Yes; 1x conversion cycle time","Wire-break":"Yes; Measuring range 4 to 20 mA only","description":"SIPLUS ET 200SP F-AI 4xI 2-/4-wire HF based on 6ES7136-6AA00-0CA1 with conformal coating, -30…+60 °C, fail-safe analog inputs up to PL e (ISO 13849) up to SIL 3 (IEC 61508)","Step: Medium":"Yes; 8x / 16x conversion cycle time","4 mA to 20 mA":"Yes","Short-circuit":"Yes","Shielded, Max.":"1 000 m","Parameterizable":"Yes","Weight, approx.":"48 g","lifecycle_stage":"current","Diagnostic alarm":"Yes","Power loss, typ.":"2 W","Rated value (DC)":"24 V","usable BaseUnits":"BU type A0, A1","Limit value alarm":"Yes","FW update possible":"Yes","Between The Channels":"No","Output current, max.":"300 mA; total current of all encoders/channels","Integration time (ms)":"20 / 16,667","Isolation tested with":"707 V DC (type test)","Measurement principle":"Sigma Delta","SIL acc. to IEC 61508":"SIL 3","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; green/red LED","For Channel Diagnostics":"Yes; red LED","For current measurement":"4","Number of analog inputs":"4","Short-circuit protection":"Yes","between the inputs (UCM)":"10 Vpp","Current consumption, max.":"0.4 A","Number of smoothing levels":"7","Calibration possible in RUN":"No","Reverse polarity protection":"Yes","Vertical Installation, Max.":"50 °C; = Tmax","Vertical Installation, Min.":"-30 °C; = Tmin","Horizontal Installation, Max.":"60 °C; = Tmax; +70 °C with configured empty slots to the left and right of the module","Horizontal Installation, Min.":"-30 °C; = Tmin (incl. condensation/frost)","Input resistance (0 to 20 mA)":"125 Ω","Monitoring the supply voltage":"Yes","Common mode interference, min.":"70 dB","Electronic coding element type F":"Yes","Input resistance (4 mA to 20 mA)":"125 Ω","Category according to ISO 13849-1":"Cat. 4","Current consumption (rated value)":"0.38 A","Integration time, parameterizable":"Yes","Burden of 2-wire transmitter, max.":"650 Ω","Reparameterization possible in RUN":"No","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Between The Channels And Backplane Bus":"Yes","Power available from the backplane bus":"70 mW","Current, relative to input range, (+/-)":"0.1 %","Monitoring of the supply voltage (PWR-LED)":"Yes; green PWR LED","Performance level according to ISO 13849-1":"PLe","Installation altitude above sea level, max.":"4 000 m","For Current Measurement As 2-Wire Transducer":"Yes","For Current Measurement As 4-Wire Transducer":"Yes","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Low demand mode: PFDavg in accordance with SIL3":"< 5.00E-05","Linearity error (relative to input range), (+/-)":"0.1 %","Temperature error (relative to input range), (+/-)":"0.023 %/K","Ambient air temperature-barometric pressure-altitude":"Restrictions for installation altitudes > 2 000 m, see entry ID: 109771992","Resolution with overrange (bit including sign), max.":"16 bit","High demand/continuous mode: PFH in accordance with SIL3":"< 1.00E-09 1/h","Color code for module-specific color identification plate":"CC00","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Between The Channels And The Power Supply Of The Electronics":"Yes","Interference voltage suppression for interference frequency f1 in Hz":"50 / 60 Hz","Permissible Input Current For Current Input (Destruction Limit), Max.":"35 mA","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.1 %","Series mode interference (peak value of interference < rated value of input range), min.":"40 dB","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e51396e92b3a763c69906944371f4bb2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1268276&mlfb=6AG1136-6AA00-2CA1"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1136-6AA00-2CA1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1136-6AA00-2CA1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}