{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1136-6RA00-2BF0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1136-6RA00-2BF0","canonicalUrl":"https://aoctrl.com/siemens/6AG1136-6RA00-2BF0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1136-6RA00-2BF0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS S7-1200 digital output module, 1 relay output (2 NO contacts), 24 V DC rated supply, 230 V AC switching, 5 A at 40 °C, 90 g.","salesMarkdown":"## Relay Output Module for S7-1200 SIPLUS Line The Siemens 6AG1136-6RA00-2BF0 is a SIPLUS S7-1200 digital output module with one relay output, two normally open contacts. It switches resistive or inductive loads up to 230 V AC (rated switching voltage) and 24 V DC, with a minimum switching current of 1 mA. Supply is 24 V DC, typical power loss 1 W. The module carries I&M data (I&M0–I&M3) and firmware update capability. Diagnostics are supported, with channel status and a combined green/red DIAG LED. ## Temperature Derating – What the Ratings Mean Horizontal installation supports up to 60 °C standard, 70 °C with empty left/right slots. Vertical installation max is 50 °C. Minimum ambient for both is -30 °C (including condensation/frost). ## Safety and Isolation Module is SIL 3, isolation tested at 2 545 V DC for 2 s, relay output rated B300 and R300, and channel-to-channel isolation for SELV/PELV only.","metaTitle":"Siemens 6AG1136-6RA00-2BF0 Relay Output Module, 1 Relay 2NO","metaDescription":"SIPLUS S7-1200 relay output module, 24 V DC, 1 relay 2NO, 5 A at 40°C, current production. SIL 3, diagnostics, isolated. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Depth":"58 mm","Width":"20 mm","title":"6AG1136-6RA00-2BF0","Height":"73 mm","Inputs":"1 byte","RUN LED":"Yes; green/red DIAG LED","I&M data":"Yes; I&M0 to I&M3","description":"SIPLUS ET 200SP F-RQ DC 24V/24-230V AC/5A based on 6ES7136-6RA00-0BF0 with conformal coating, -30…+60 °C, 20 mm overall width, 1 relay output (2 NO) summation output current 5 A, load voltage 24 V DC and 24... 230 V AC, can be used up to PL e (ISO 13849-1: 2008)/ SIL 3 (IEC 61508: 2010) if controlled by F-DQ (e.g. 6AG1136-6DB00-2CA0)","Shielded, Max.":"500 m; for load contacts","Weight, approx.":"90 g","lifecycle_stage":"current","Power loss, typ.":"1 W","Rated value (DC)":"24 V","Unshielded, Max.":"300 m; for load contacts","usable BaseUnits":"BU type F0","FW update possible":"Yes","On Lamp Load, Max.":"25 W","up to 40 °C, max.":"5 A; note derating data in the manual","up to 50 °C, max.":"3 A; note derating data in the manual","up to 60 °C, max.":"3 A; note derating data in the manual","up to 70 °C, max.":"3 A; note derating information in the manual; only with configured slots to the left and right of the module","Between The Channels":"Yes; for SELV / PELV only","Diagnostics function":"Yes","Overvoltage category":"3","Isolation tested with":"2 545 V DC/2 s (routine test)","SIL acc. to IEC 61508":"SIL 3","Channel status display":"Yes; green LED","Type of digital output":"Relays","Number of relay outputs":"1; 2 NO contacts","Switching current, min.":"1 mA","Number of digital outputs":"1","With Inductive Load, Max.":"see additional description in the manual","With Resistive Load, Max.":"see additional description in the manual","Control cable (input), max.":"10 m","Controlling a digital input":"Yes","Vertical Installation, Max.":"50 °C; = Tmax","Vertical Installation, Min.":"-30 °C; = Tmin","Rated switching voltage (AC)":"230 V","Rated switching voltage (DC)":"24 V","Horizontal Installation, Max.":"60 °C; = Tmax; +70 °C with configured empty slots to the left and right of the module","Horizontal Installation, Min.":"-30 °C; = Tmin (incl. condensation/frost)","Relay approved acc. to UL 508":"Yes; Pilot Duty B300, R300","Suitable for safety functions":"Yes","Thermal continuous current, max.":"5 A","Category according to ISO 13849-1":"4","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","External Protection For Relay Outputs":"yes; 6 A, see data in manual","Between The Channels And Backplane Bus":"Yes","Power available from the backplane bus":"100 mW","Performance level according to ISO 13849-1":"PLe","Rated supply voltage of relay coil L+ (DC)":"24 V","Installation altitude above sea level, max.":"2 000 m","Limitation of inductive shutdown voltage to":"No","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Switching current after exceeding 300 mA, max.":"5 A","Switching current after exceeding 300 mA, min.":"10 mA","Low demand mode: PFDavg in accordance with SIL2":"< 1.00E-04, function test 1x per year","Low demand mode: PFDavg in accordance with SIL3":"< 1.00E-05, function test 1x per month","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)","High demand/continuous mode: PFH in accordance with SIL2":"< 1.00E-08 1/h, function test 1x per year","High demand/continuous mode: PFH in accordance with SIL3":"< 6.00E-09 1/h, function test 1x per month","Color code for module-specific color identification plate":"CC42","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Between The Channels And The Power Supply Of The Electronics":"Yes","Current consumption of relays (coil current of all relays), max.":"70 mA","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e51396e92b3a763c69906944371f4bb2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=752578&mlfb=6AG1136-6RA00-2BF0"},"ai":{"faq":[{"question":"Does this module support diagnostics?","answer":"Yes, diagnostics are supported, including channel status display and a DIAG LED. I&M data up to I&M3 is available."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1136-6RA00-2BF0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1136-6RA00-2BF0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}