{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1137-6BD00-2BA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1137-6BD00-2BA0","canonicalUrl":"https://aoctrl.com/siemens/6AG1137-6BD00-2BA0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1137-6BD00-2BA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 6AG1137-6BD00-2BA0 IO-Link Master, 4 ports, 24 V DC, 700 mA per channel, width 15 mm, lifecycle current.","salesMarkdown":"The 6AG1137-6BD00-2BA0 is a 4-port IO-Link master module in the Siemens TIA selection, powered at 24 VDC and rated 700 mA per channel for sensor/actuator supply. Transmission rates: 4.8 kBaud (COM1), 38.4 kBaud (COM2), and 230.4 kBaud (COM3). Each port provides diagnostics, short-circuit protection, and wire-break detection, with a green/red LED per channel for status. Digital inputs (DI=Yes) and digital outputs (DQ=Yes, max. 100 mA per channel) are integrated, along with I&M data support for I&M0 to I&M3. ## Integration constraints Isochronous mode and TIO IO-Link IN/OUT are not supported on this module; these features are available only for PROFINET variants with firmware V2.0 or V2.1. The module mounts using BU type A0 base units. Port type B requires a 24 VDC external terminal. Maximum unshielded cable length is 20 m, which also applies to shielded. Power consumption without load is 45 mA max; total output current across all channels is limited to 2.1 A.","metaTitle":"Siemens 6AG1137-6BD00-2BA0 IO-Link Master, 4 ports, 24 VDC","metaDescription":"Active-current 4-port IO-Link master from Siemens, 24 VDC, 700mA per channel, I&M data, diagnostic alarms. Source via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"DI":"Yes","DQ":"Yes; max. 100 mA per channel","Depth":"58 mm","Width":"15 mm","title":"6AG1137-6BD00-2BA0","Height":"73 mm","IO-Link":"Yes","I&M data":"Yes; I&M0 to I&M3","Wire-break":"Yes","Group error":"Yes","Port type A":"Yes","Port type B":"Yes; 24 V DC via external terminal","Rated value":"700 mA; Per channel","description":"SIPLUS ET 200SP CM 4xIO-LINK based on 6ES7137-6BD00-0BA0 with conformal coating, -40…+60 °C, communication module IO-Link master V1.1","Short-circuit":"Yes","TIO IO-Link IN":"No; Only for PROFINET and configuration as version with FW V2.0 or V2.1","Number of ports":"4","TIO IO-Link OUT":"No; Only for PROFINET and configuration as version with FW V2.0 or V2.1","Weight, approx.":"30 g","lifecycle_stage":"current","Cycle time, min.":"2 ms; dynamic, depending on user data length","Diagnostic alarm":"Yes; The port diagnosis is available in the IO-Link mode only.","Isochronous mode":"No; Only for PROFINET and configuration as version with FW V2.0 or V2.1","Power loss, typ.":"1 W","Rated value (DC)":"24 V","Unshielded, Max.":"20 m; Also applies for shielded cables","usable BaseUnits":"BU type A0","Number of outputs":"4","Transmission rate":"4.8 kBaud (COM1); 38.4 kBaud (COM2), 230.4 kBaud (COM3)","Automatic encoding":"Yes","TIO IO-Link IN/OUT":"No; Only for PROFINET and configuration as version with FW V2.0 or V2.1","Between The Channels":"No","IO-Link protocol 1.0":"Yes","IO-Link protocol 1.1":"Yes","Output current, max.":"2.1 A","Isolation tested with":"707 V DC (type test)","Channel status display":"Yes; one green LED for channel status Qn (SIO mode) and port status Cn (IO-Link mode) per channel","For Module Diagnostics":"Yes; green/red DIAG LED","For Channel Diagnostics":"Yes; red Fn LED","Short-circuit protection":"Yes","Current consumption, max.":"45 mA; without load","Via Three-Wire Connection":"Yes","Between Different Circuits":"75 V DC/60 V AC (base isolation)","Reverse polarity protection":"Yes","Vertical Installation, Max.":"50 °C; = Tmax","Vertical Installation, Min.":"-40 °C; = Tmin","Cable length unshielded, max.":"20 m; max.","Horizontal Installation, Max.":"60 °C; = Tmax","Horizontal Installation, Min.":"-40 °C; = Tmin (incl. condensation/frost)","Monitoring the supply voltage":"Yes","Electronic coding element type H":"Yes","Memory size for device parameter":"2 kbyte; for each port","permissible range, lower limit (DC)":"19.2 V; 20.5 V if IO-Link is used, as the supply voltage for IO-Link devices has to be at least 20 V at the master.","permissible range, upper limit (DC)":"28.8 V","Of Which Simultaneously Controllable":"4","Size of process data, input per port":"32 byte; max.","Size of process data, output per port":"32 byte; max.","Between The Channels And Backplane Bus":"Yes","Size of process data, input per module":"144 byte; max.","Size of process data, output per module":"128 byte; max.","Monitoring of the supply voltage (PWR-LED)":"Yes; green PWR LED","Installation altitude above sea level, max.":"5 000 m","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","power supply according to NEC Class 2 required":"No","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","STEP 7 TIA Portal configurable/integrated from version":"see entry ID: 109746275","Color code for module-specific color identification plate":"CC04","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Between The Channels And The Power Supply Of The Electronics":"No","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$275.59","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e51396e92b3a763c69906944371f4bb2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=754490&mlfb=6AG1137-6BD00-2BA0"},"ai":{"faq":[{"question":"What are the key specifications for DI and DQ?","answer":"DI (digital inputs) is supported (Yes). DQ (digital outputs) is supported with a maximum of 100 mA per channel."},{"question":"What transmission rates does this IO-Link master support?","answer":"It supports COM1 (4.8 kBaud), COM2 (38.4 kBaud), and COM3 (230.4 kBaud)."},{"question":"Does this module support I&M data?","answer":"Yes, it supports I&M0 through I&M3 for device identification and asset management."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1137-6BD00-2BA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1137-6BD00-2BA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}