{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1153-2BA02-2XY0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1153-2BA02-2XY0","canonicalUrl":"https://aoctrl.com/siemens/6AG1153-2BA02-2XY0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1153-2BA02-2XY0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 6AG1153-2BA02-2XY0 PROFIBUS DP interface module, SIMATIC ET 200M, 244 bytes I/O, 12 Mbit/s, -40 to 70 °C, IP20, RS485.","salesMarkdown":"The 6AG1153-2BA02-2XY0: The I2t of 0.1 A²·s is a fuse-selection number for the module's internal protection — keep that in mind if you're coordinating the backplane supply. Power loss is 5.5 W typ, and the module draws max 600 mA from the 5 VDC backplane. The 9-pin sub-D connector is the standard PROFIBUS plug. SYNC and FREEZE capability is there for deterministic update of I/O groups. Automatic baud detection up to 12 Mbit/s saves configuration guesswork. Width is 40 mm, depth 117 mm, height 125 mm — it takes one slot in the ET 200M rack. Accepts PROFIBUS cables with the standard 9-pin D-sub; no TCP/IP on-board. For configuration: work with STEP 7 / COM PROFIBUS or any GSD-file-compatible tool using the SI04801.GSG file. Time stamp resolution is 0.466 ns per RFC 1119, and you can trigger on rising or falling edges.","metaTitle":"Siemens 6AG1153-2BA02-2XY0 PROFIBUS DP Module, 12 Mbit/s, -4","metaDescription":"Siemens 6AG1153-2BA02-2XY0 PROFIBUS DP interface module for ET 200M. 244 bytes I/O, 12 Mbit/s, -40 to 70°C, IP20. UL, FM, CE, railway certified. Active production. Sourced to order","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"I2t":"0.1 A²·s","Max.":"70 °C","Min.":"-40 °C","Depth":"117 mm","Width":"40 mm","title":"6AG1153-2BA02-2XY0","Height":"125 mm","Inputs":"244 byte","STEP 7":"Yes; STEP 7 / COM PROFIBUS / non-Siemens tools via GSD file","TCP/IP":"No","CE mark":"Yes","Outputs":"244 byte","Accuracy":"1 ms; 1 ms at up to 8 modules; 10 ms at up to 12 modules","EN 50155":"Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B","GSD file":"SI04801.GSG","FM approval":"Yes; CofC 3028431","KC approval":"Yes","Time format":"RFC 1119","UL approval":"Yes; File E239877","description":"***Spare part*** SIPLUS ET 200M IM 153-2 -25...+60°C according to EN 50155 with conformal coating based on 6ES7153-2BA02-0XB0","SYNC capability":"Yes","Time resolution":"0.466 ns","Weight, approx.":"360 g","lifecycle_stage":"current","Power loss, typ.":"5.5 W","Rated value (DC)":"5 V","FREEZE capability":"Yes","Inrush current, typ.":"3 A","EAC (formerly Gost-R)":"Yes","Isolation tested with":"500V AC for 1 minute","RCM (formerly C-TICK)":"Yes","Transmission procedure":"RS 485","IP degree of protection":"IP20","Transmission rate, max.":"12 Mbit/s","Design of the connection":"9-pin sub D socket","Current consumption, max.":"600 mA","Number of message buffers":"15","Automatic Baud Rate Search":"Yes","Messages per message buffer":"20","Potential separation exists":"Yes","Time stamp on signal change":"rising / falling edge as signal entering or exiting","Number of node addresses, max.":"1 to 125 permitted","for backplane bus (5 V DC), max.":"1.5 A","Bus protocol/transmission protocol":"PROFIBUS DP to EN 50170","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","Output current of the interface, max.":"70 mA","Automatic Detection Of Transmission Rate":"Yes","Mains/voltage failure stored energy time":"5 ms","Number of stampable digital inputs, max.":"128; Max. 128 signals/station; max. 32 signals/slot","Number of modules per DP slave interface, max.":"12","Direct data exchange (slave-to-slave communication)":"Yes; Sender","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","External Protection For Power Supply Lines (Recommendation)":"2,5 A","Time interval for transmitting the message buffer if a message is present":"1 000 ms"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$632.46","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a8a36b8f10a30a3bcb80310048e52ad2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=107498&mlfb=6AG1153-2BA02-2XY0"},"ai":{"faq":[{"question":"What is the I2t rating of the 6AG1153-2BA02-2XY0?","answer":"The listed I2t is 0.1 A²·s. This helps with fuse sizing for the module's backplane protection."},{"question":"What is the maximum operating temperature for the 6AG1153-2BA02-2XY0?","answer":"The operating temperature range is -40°C to 70°C. It's suitable for railway and other harsh environments."},{"question":"What compliance documentation does Siemens provide for the 6AG1153-2BA02-2XY0?","answer":"The module carries UL file E239877, FM approval (CofC 3028431), CE mark, KC approval, EAC (Gost-R), and RCM (C-TICK). RoHS/REACH declarations are part of the standard Siemens documentation package."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1153-2BA02-2XY0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1153-2BA02-2XY0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}