{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1153-2BA02-7XB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1153-2BA02-7XB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1153-2BA02-7XB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1153-2BA02-7XB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC DP, PROFIBUS DP interface module, 6AG1153-2BA02-7XB0, 12 Mbit/s, 0.466 ns time resolution, I2t 0.1 A²·s.","salesMarkdown":"## PROFIBUS DP interface with time-stamping The Siemens 6AG1153-2BA02-7XB0 is a PROFIBUS DP slave interface module providing time stamping on signal change with 0.466 ns resolution, storing up to 15 message buffers each holding 20 events, and supporting automatic baud rate search up to 12 Mbit/s. Transmission protocol follows PROFIBUS DP to EN 50170, with a 9-pin sub-D connector. The module integrates into the backplane bus and draws a maximum of 600 mA from the 5 V DC supply. Potential separation is present; isolation tested at 500 V. ## Key ratings and protection The I2t rating of 0.1 A²·s defines the let-through energy that the module can withstand; coordinate upstream protection accordingly. Inrush current is typ. 3 A at cold restart. Power loss is typ. 5.5 W. The module's current consumption on the backplane bus (5 V DC) is 1.5 A max. Time stamping accuracy is 1 ms with up to 8 modules, degrading to 10 ms with up to 12 modules. Time format follows RFC 1119. Configuration is supported in STEP 7, COM PROFIBUS, or via the GSD file SI04801.GSG for non-Siemens tools.","metaTitle":"Siemens 6AG1153-2BA02-7XB0 PROFIBUS DP Module, 12 Mbit/s","metaDescription":"Siemens 6AG1153-2BA02-7XB0 PROFIBUS DP interface module, currently in production. Rated 12 Mbit/s, 0.466 ns time resolution, I2t 0.1 A²·s. UL/CE/FM/EAC/RCM approved. Order to RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"I2t":"0.1 A²·s","Max.":"70 °C; = Tmax; 60 °C @ UL/cUL use","Min.":"-40 °C; = Tmin","Depth":"117 mm","Width":"40 mm","title":"6AG1153-2BA02-7XB0","Height":"125 mm","Inputs":"244 byte","STEP 7":"Yes; STEP 7 / COM PROFIBUS / non-Siemens tools via GSD file","TCP/IP":"No","CE mark":"Yes","Outputs":"244 byte","Accuracy":"1 ms; 1 ms at up to 8 modules; 10 ms at up to 12 modules","GSD file":"SI04801.GSG","FM approval":"Yes; CofC 3028431","KC approval":"Yes","Time format":"RFC 1119","UL approval":"Yes; File E239877","description":"***Spare part*** SIPLUS ET 200M IM 153-2 (*BA02) -40...+70°C start up temperature: -25°C with conformal coating based on 6ES7153-2BA02-0XB0 Connection ET 200M for max. 12 S7-300 modules with redundancy capability, Timestamping suitable for isochronous mode Operation New features: up to 12 modules can be used Slave Initiative for Drive ES and Switch ES Expanded quantity structure for HART auxiliary variables Operation of the 64-channel modules 32 signals/slot","SYNC capability":"Yes","Time resolution":"0.466 ns","Weight, approx.":"360 g","lifecycle_stage":"current","Power loss, typ.":"5.5 W","Rated value (DC)":"5 V","FREEZE capability":"Yes","Inrush current, typ.":"3 A","At cold restart, min.":"-25 °C","EAC (formerly Gost-R)":"Yes","Isolation tested with":"Isolation voltage 500 V","RCM (formerly C-TICK)":"Yes","Transmission rate, max.":"12 Mbit/s","Design of the connection":"9-pin sub D socket","Current consumption, max.":"600 mA","Number of message buffers":"15","Automatic Baud Rate Search":"Yes","Messages per message buffer":"20","Potential separation exists":"Yes","Time stamp on signal change":"rising / falling edge as signal entering or exiting","for backplane bus (5 V DC), max.":"1.5 A","Bus protocol/transmission protocol":"PROFIBUS DP to EN 50170","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","Output current of the interface, max.":"70 mA","Automatic Detection Of Transmission Rate":"Yes","Mains/voltage failure stored energy time":"5 ms","Number of stampable digital inputs, max.":"128; Max. 128 signals/station; max. 32 signals/slot","Number of modules per DP slave interface, max.":"12","Direct data exchange (slave-to-slave communication)":"Yes; Sender","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Time interval for transmitting the message buffer if a message is present":"1 000 ms"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$443.48","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a8a36b8f10a30a3bcb80310048e52ad2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=524382&mlfb=6AG1153-2BA02-7XB0"},"ai":{"faq":[{"question":"What is the I2t rating of this module?","answer":"The I2t rating is 0.1 A²·s, which defines the let-through energy for protection coordination."},{"question":"What is the maximum operating temperature?","answer":"The ambient operating range is -40°C to 70°C; when used under UL/cUL recognition, it is derated to 60°C."},{"question":"What compliance certifications does this module carry?","answer":"It holds UL (File E239877), FM (CofC 3028431), CE, KC, EAC, and RCM approvals."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1153-2BA02-7XB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1153-2BA02-7XB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}