{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1155-6AU01-7CN0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1155-6AU01-7CN0","canonicalUrl":"https://aoctrl.com/siemens/6AG1155-6AU01-7CN0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1155-6AU01-7CN0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 6AG1155-6AU01-7CN0 PROFINET BusAdapter, 2 ports, IRT high performance, 0.25 A²·s, 24 V DC.","salesMarkdown":"The Siemens 6AG1155-6AU01-7CN0 PROFINET BusAdapter brings two ports to the ET 200AL family, carrying IRT with high performance down to 250 µs cycles — jitter holds under 1 µs, so it fits into motion-control isochronous loops without additional latency. The module draws 2.4 W from the 24 V DC rail, with a 50 mm footprint that slides onto the DIN rail alongside other ET 200AL slices. ## Key ratings so-what I2t is listed at 0.25 A²·s — that's the internal fuse energy rating, so upstream protection should coordinate below that threshold to avoid nuisance trips. IRT with high performance supports cycle times from 250 µs to 4 ms in 125 µs frames, plus standard IRT at 250 µs, 500 µs, 1 ms, 2 ms, and 4 ms. That gives flexibility for both high-speed and standard isochronous applications. Supports MRP, LLDP, SNMP, I&M0–I&M3, and Shared Device — so it integrates into managed PROFINET networks with redundancy and diagnostics.","metaTitle":"Siemens 6AG1155-6AU01-7CN0 PROFINET BusAdapter, IRT","metaDescription":"Active-production Siemens PROFINET BusAdapter with 2 ports, IRT high performance, 0.25 A²·s I2t. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"NRND","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"I2t":"0.25 A²·s","IRT":"Yes; 250 μs, 500 μs, 1 ms, 2 ms, 4 ms additionally with IRT with high performance: 250 µs to 4 ms in 125 µs frame","MRP":"Yes","LLDP":"Yes","MRPD":"No","SNMP":"Yes","Depth":"74 mm","Width":"50 mm","title":"6AG1155-6AU01-7CN0","Alarms":"Yes","Height":"117 mm","TCP/IP":"Yes","10 Mbps":"No","RUN LED":"Yes; green LED","100 Mbps":"Yes; PROFINET with 100 Mbit/s full duplex (100BASE-TX)","Accuracy":"10 ms","I&M data":"Yes; I&M0 to I&M3","ERROR LED":"Yes; red LED","MAINT LED":"Yes; Yellow LED","Max. Cycle":"4 ms","PROFIenergy":"Yes","Via Dataset":"Yes","description":"Siemens 6AG1155-6AU01-7CN0 — now in phase-out and being discontinued. Supplied from remaining channel stock; full specifications, lifecycle and same-series options are below.","Autocrossing":"Yes","Equidistance":"Yes","Jitter, max.":"1 µs","Tool changer":"Yes; Docking station and docking unit","Shared device":"Yes","Strain relief":"Yes; Optional","Security level":"According to Security Level 1 Test Cases V1.1.1","via BU/BA Send":"Yes; + 16 ET 200AL modules","Autonegotiation":"Yes","Number of ports":"2; via BusAdapter","Weight, approx.":"120 g; without BusAdapter","lifecycle_stage":"current","Isochronous mode":"Yes","Media redundancy":"Yes; PROFINET MRP","Power loss, typ.":"2.4 W","Rated value (DC)":"24 V","Status indicator":"Yes","H-Sync forwarding":"Yes","Integrated Switch":"Yes","FW update possible":"Yes","PROFINET IO Device":"Yes","Prioritized startup":"Yes","Diagnostics function":"Yes","Inrush current, max.":"4.5 A","Shortest Clock Pulse":"250 µs","BusAdapter (PROFINET)":"Yes; Compatible BusAdapter: BA 2x RJ45, BA 2x FC, BA 2x SCRJ, BA SCRJ / RJ45, BA SCRJ / FC, BA 2x LC, BA LC / RJ45, BA LC / FC","Isolation tested with":"707 V DC (type test)","Network loading class":"3","Open IE communication":"Yes","Modules per rack, max.":"64; + 16 ET 200AL modules","Transmission procedure":"PROFINET with 100 Mbit/s full duplex (100BASE-TX)","Local coupling, IO data":"No","Current consumption, max.":"700 mA","Bus cycle time (TDP), min.":"250 µs","Reverse polarity protection":"Yes","Vertical Installation, Max.":"50 °C; = Tmax","Vertical Installation, Min.":"-40 °C; = Tmin (incl. condensation/frost)","Local coupling, data records":"No","Connection display LINK TX/RX":"Yes; 2x green link LEDs on BusAdapter","Horizontal Installation, Max.":"70 °C; = Tmax","Horizontal Installation, Min.":"-40 °C; = Tmin (incl. condensation/frost)","Number of PROFINET interfaces":"1; 2 ports (switch)","Address space per module, max.":"288 byte; For input and output data respectively","Address space per station, max.":"1 440 byte; Dependent on configuration","PROFINET system redundancy (R1)":"No","PROFINET system redundancy (S2)":"Yes; NAP S2","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Between Backplane Bus And Electronics":"No","Between Supply And All Other Circuits":"No","Number of submodules per station, max.":"256","between PROFINET and all other circuits":"Yes","Mains/voltage failure stored energy time":"10 ms","Monitoring of the supply voltage (PWR-LED)":"Yes; green PWR LED","Installation altitude above sea level, max.":"5 000 m","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Module swapping during operation (hot swapping)":"Yes; Multi-hot swapping","Number of IO Controllers with shared device, max.":"4","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","STEP 7 TIA Portal configurable/integrated from version":"see entry ID: 109746275","Number of MtM communication relationships/connections, max.":"16","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a8a36b8f10a30a3bcb80310048e52ad2.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1392721&mlfb=6AG1155-6AU01-7CN0"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1155-6AU01-7CN0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1155-6AU01-7CN0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-06-30T18:11:17.139Z","lastPublished":"2026-06-30T18:11:17.139Z","indexable":true}}