{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1193-6AG20-2AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1193-6AG20-2AA0","canonicalUrl":"https://aoctrl.com/siemens/6AG1193-6AG20-2AA0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1193-6AG20-2AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS ET 200SP BA LC/RJ45, 6AG1193-6AG20-2AA0, media converter with 1x LC FO and 1x RJ45, conformal coating, -40 to 60 °C, 59 x 20 x 69.5 mm.","salesMarkdown":"## What this media converter does in a harsh panel The 6AG1193-6AG20-2AA0 is a SIPLUS ET 200SP BusAdapter that converts between one 100BASE-FX LC fiber-optic port (multimode up to 3 km) and one RJ45 copper port. This is the conformal-coated variant of the standard 6ES7193-6AG20-0AA0, built to survive where condensation, coolant mist, and airborne oil are the norm rather than the exception. ## Temperature range and environmental sealing Rated for -40 °C to 60 °C in horizontal installation, and -40 °C to 50 °C when mounted vertically — the vertical derating reflects reduced convection in a tall cabinet. The full operating envelope extends to 5000 m altitude with a 20 K derating above 3500 m, so it works in high-altitude switchgear rooms without a second thought. The conformal coating (IPC-CC-830A Class A) and Type 1 fouling protection per EN 60664-3 mean the board is sealed against conductive deposits. It also carries resistance to commercially available coolants and lubricants, including diesel and oil droplets, and meets ANSI/ISA-71.04 GX Group A/B for corrosive gas environments. This is not a clean-room part — it is built for the nacelle, the kiln side, the washdown zone. The module is 20 mm wide, 69.5 mm high, and 59 mm deep — it snaps onto the ET 200SP backplane bus and takes one width unit in the I/O rack. No DIN-rail footprint of its own; it mounts as part of the distributed I/O station. The LC port uses a standard duplex LC connector for multimode fiber; the RJ45 port is a standard shielded copper jack. Hardware functional status from FS04 is required — check the revision marking on the side before commissioning, especially if you are swapping into an existing backplane.","metaTitle":"Siemens 6AG1193-6AG20-2AA0 SIPLUS ET 200SP BA LC/RJ45","metaDescription":"Siemens 6AG1193-6AG20-2AA0 SIPLUS ET 200SP media converter, 1x LC FO + 1x RJ45, conformal coating, -40 to 60°C, active production. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Max.":"60 °C; = Tmax","Min.":"-40 °C; = Tmin (incl. condensation/frost)","Depth":"59 mm","Width":"20 mm","Height":"69.5 mm","Cu conductors":"100 m","Weight, approx.":"32 g","lifecycle_stage":"current","Number of LC ports":"1; Wavelength of 1 270 ... 1 380 nm, corresponds to 100BASE-FX","HW functional status":"from FS04","Number of RJ45 ports":"1","Number of SCRJ ports":"0","Vertical Installation, Max.":"50 °C","Vertical Installation, Min.":"-40 °C","Horizontal Installation, Max.":"60 °C","Horizontal Installation, Min.":"-40 °C","Number of PROFINET interfaces":"1; 2 ports (switch) LC / RJ45","Multimode graded-index fiber 50/125 μm":"3 km","Multimode graded-index fiber 62.5/125 μm":"3 km","Installation altitude above sea level, max.":"5 000 m","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/341e3518f97b4bb5550fbec63f57fa84.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1556501&mlfb=6AG1193-6AG20-2AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AG1193-6AG20-2AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the difference between 6AG1193-6AG20-2AA0 and the standard 6ES7193-6AG20-0AA0?","answer":"This SIPLUS variant adds conformal coating (IPC-CC-830A Class A), Type 1 fouling protection, and resistance to coolants, lubricants, diesel, and oil droplets. The standard unit lacks these environmental protections. The base function — one LC fiber port and one RJ45 port on a single PROFINET interface — is identical."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1193-6AG20-2AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1193-6AG20-2AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}